User manual HONEYWELL DC76 DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HONEYWELL DC76. We hope that this HONEYWELL DC76 user guide will be useful to you.

Lastmanuals help download the user guide HONEYWELL DC76.


Mode d'emploi HONEYWELL DC76
Download
Manual abstract: user guide HONEYWELL DC76DATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] HabeDos DC76 Dosing computer for water treatment to combat corrosion and limescale buildup Produkt-Datenblatt Application HabeDos dosing computers are electronically controlled appliances for reducing the occurrence of corrosion in drinking water pipework. They can also be used for renovating corroded pipework. [. . . ] 40 °C 10. 0 bar 230 V / 24 V / 50 Hz 100 ml/m³ IP 54 Max. 1. 2 m · · · · · Control and pump unit Dosing section Water meter with impulse transmitter Check valve Connection fittings Dosing pipework and valve, including suction lance Level sensor (protection against dry running) Control electronics with light diodes to indicate operation, dosing frequency and need for container exchange Transformer with1. 5 metre mains cable Cover with clear viewing plate and childproofing Supplied without dosing solution (see accessories Range of Application Water temperature Ambient temperature Operating pressure Technical Data Electrical supply Dosing quantity Protection class Suction lift Electrical connection power 10 VA · · · · · · · EN0H-1404GE23 R1106 Materials · Brass dosing section, water meter and connection fittings · · PVC suction lance High grade synthetic material cover www. honeywell. com 1 HabeDos DC76 Dosing computer for water treatment Function When water is drawn off an impulse sensor detects the actual flow rate and registers this in the electronic system. The electronic system then regulates an actuator motor for the dosing pump and thereby ensures precise proportional dosing of the active solution across the whole operating range. The active solution is sucked out of the storage container and is injected into the pipework. At the same time the dosing frequency is indicated by flashing the LED's. An electronic level sensor switches the pump off if the solution in the storage container is too low and thereby protects the pump against dry running. The necessity for container replacement is signalled both visually and acoustically. If malfunction occurs, then the automatic control system prevents the risk of overdosing by shutting off the system. Versions DC76-A = With suction lance L1 L2 Connection threads (external) Operating weight Dimensions approx. kg (mm) L1 L2 H Distance from wall to centre of pipework Operating range Permissible continuous flow rate Pressure loss at max. (bar) (l/h) H R 1" 6. 3 277 190 260 30 - 6000 0. 5 R 1 1/4" 6. 5 292 190 260 min. 55 mm 30 - 10000 0. 8 DW-9111BM0075 R 1 1/2" 7. 7 315 190 260 50 - 20000 0. 8 Approx. [. . . ] This electrical supply must be continuous Install shutoff valves Ensure good access o · · · · Simplifies maintenance and inspection The installation location should be protected against frost and extreme heat The installation location must be protected against frost and strong heat All work must be carried out only by competent persons The device is fitted with a check valve and therefore must not be fitted between a water heater and the pressure relief safety valve Only Honeywell VC76 is permitted as a replacement solution The dosing section with water meter must be installed horiziontally Range of Application HabeDos dosing computers can be fitted wherever corrosion and limescale buildup are to be prevented. HabeDos dosing computers may be fitted: · · · · After water meters and filters For the sanitization of pipelines in old buildings In domestic hot water systems Centrally or locally upstream of hot water heaters in single family or multi-occupation dwellings · · Subject to change without notice · · EN0H-1404GE23 R1106 www. honeywell. com 3 HabeDos DC76 Dosing computer for water treatment ACS Control Products Honeywell GmbH Hardhofweg D-74821 Mosbach, Germany Phone: +49 (6261) 810 Fax: +49 (6261) 81393 www. honeywell. com Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell Technologies Sàrl, Ecublens, Route du Bois 37, Switzerland by its Authorised Representative Honeywell GmbH EN0H-1404GE25 R1106 Subject to change without notice © 2006 Honeywell GmbH [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL DC76

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL DC76 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag