User manual HONEYWELL DRR-HE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HONEYWELL DRR-HE. We hope that this HONEYWELL DRR-HE user guide will be useful to you.

Lastmanuals help download the user guide HONEYWELL DRR-HE.


Mode d'emploi HONEYWELL DRR-HE
Download
Manual abstract: user guide HONEYWELL DRR-HE

Detailed instructions for use are in the User's Guide.

[. . . ] THREE-WAY ROTARY VALVE PN10 AND HE25 EXTENSION PRODUCT DATA DRR/HE FEATURES · Chrome-plated plug for long life-span · Optimized characteristics for supply water temperature control · All around changeable rotary plug · Reliable and easy mounting of electrical actuators · Wide range of flow rates in two housing sizes · Compact design · Use for manifolds by accessory HE25 Extension · Thermal insulation package included APPLICATION The DRR25 Three-Way Rotary Valve provides water temperature control in heating and air-conditioning applications. These valves are designed for accurate mixing control of supply water temperature and return-flow temperature. [. . . ] The required flow water temperature is achieved by adding a proportion of return water to the boiler hot water. The DRR has special control characteristics for optimal control performance. SUITABLE ACTUATORS torque [Nm] 10 20 OS no. 0/2. . . 10V M7061E1012 M7061E1020 / VRM20 MOUNTING Adjustments for Mixing Applications 0 9 9 0 9 0 0 9 EN0B-0611GE51 R1108 2 DRR/HE ­ PRODUCT DATA Mounting the Actuator SPECIFICATION AND ORDER NUMBER PER DN OS No. DRU25-2. 5 DRU25-4. 0 DRU25-6. 3 DRU25-10 DRU25-16 HE25 DN 25 25 25 25 25 25 kvs [m³/h] 2. 5 4. 0 6. 3 10. 0 16. 0 heat flow [kW] 7-12 12-17 17-30 30-50 50-70 p [kPa] 100 100 100 100 100 nom. torque [Nm] 10 10 10 10 10 actuator floating M6061A1013, M6061A1021 / VMM20-24, M6061L1019, M6061L1027 / VMM20 modulating M7061E1012, M7061E1020 / VRM20 - ACCESSORIES connection set description Welding sockets with gasket and cap nut DN pipe size [mm] weight [kg] OS No. 25 25 0. 3 WTU25 Soldering sockets with gasket and cap nut 25 25 25 18 22 28 0. 21 0. 21 0. 21 LSU25-18 LSU25-22 LSU25-28 Internal threaded sockets with gasket and cap nut 25 25 0. 21 STU25 3 EN0B-0611GE51 R1108 DRR/HE ­ PRODUCT DATA DIMENSIONS DRR type DRR25-2. 5 DRR25-4. 0 DRR25-6. 3 DRR25-10 DRR25-16 DN 25 25 25 25 25 a 55 55 55 55 55 b 32 32 32 32 32 c 110 110 110 110 110 d 89 89 89 89 89 e 55 55 55 55 55 g 51 51 51 51 51 h 182 182 182 182 182 R 1½ 1½ 1½ 1½ 1½ weight [kg] 2. 48 2. 48 2. 50 2. 53 2. 51 a b d R c e g g h HE type HE25 = g DN 25 a 110 b 42 e 55 b f 0-25 g 51 R 1½ weight [kg] 1. 7 f e a R EN0B-0611GE51 R1108 4 DRR/HE ­ PRODUCT DATA HYDRAULIC FUNCTION Characteristics 100% 80% 60% 40% 20% 0% HE25 2 3 4 5 6 7 8 9 Spare Parts · O-ring (part no. : 07169 9535) 5 EN0B-0611GE51 R1108 DRR/HE ­ PRODUCT DATA VALVE DIMENSIONING Honeywell Rotary Valves are employed mainly in hydraulic systems corresponding to the examples shown on page 2. The rotary valve can be set quite easily. In order to obtain good control characteristics, the pressure drop in the rotary valve should be about the same as the pressure drop in the "volume-variable" part of the pipe system, i. e. The following dimensioning diagram is based on this interrelationship. 4. & Find heat flow Q in the diagram. & Move vertically upwards to the intersection with the corresponding line. On the vertical axis, the volume flow V can be read off on the left in liters per hour. Move horizontally to the right from the intersection with the line into the shaded section (1. 5-4. 0 kPa). [. . . ] is the temperature difference between supply and return flow in Kelvin) Unit Conversion 1 kW = 3600 kJ/h = 860 kcal/h 1000 kcal/h = 1. 163 kW 1 bar = 100 kPa = 10 m water column 1 mbar = 10 mm water column Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell Technologies Sàrl, Rolle, Z. A. La Pièce 16, Switzerland by its Authorized Representative: Automation and Control Solutions Honeywell GmbH Böblinger Strasse 17 71101 Schönaich Germany Phone: (49) 7031 63701 Fax: (49) 7031 637493 http://ecc. emea. honeywell. com Subject to change without notice. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL DRR-HE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL DRR-HE will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag