Manual abstract: user guide HONEYWELL DU144

Detailed instructions for use are in the User's Guide.

[. . . ] en er g y saving DU144 Automatic Bypass Valve www. energysavingtrust. org. uk INSTALLATION INSTRUCTIONS Building Regulations An Automatic Bypass Valve (DU144) controls water flow in the Heating Circuit according to the water pressure across it and is used to maintain a minimum flow rate through the boiler and to limit circulation pressure when other water paths are closed. [. . . ] Do not over tighten. Setting Procedure 1) Commission and balance the Heating System ­ take note of the selected pump speed. 2) Using the Boiler manufacturer's instructions, find the minimum flow requirement for the Boiler. 3) Using the Pump manufacturer`s Pump curves determine the available Pump head when operating at the required minimum flow and the selected Pump speed. 4) Using the DU144 Setting chart, the calculated Pump Head and the minimum Boiler Flow to find the optimum setting for the DU144 Note: To set the DU144, remove the protective cap and turn the setting handle until the bottom of the handle crosses the corresponding line on the DU144 stem. Note: The cap is internally fixed with sealing wax during assembly. Should persistent water velocity noise occur in the Heating System, gradually turn the DU144 to a lower setting until the noise is eliminated. Important: replace protective cap after setting the DU144 to avoid tampering Example: Minimum flow 300 l/h - Pump speed 3. Pump chart indicates 4 m head (Use Pump Manufactures chart). Pump Head 3) Available head (example 4m) 5m 4m 3m 2m 1m Flow l/h 2) 300 l/h Boiler min. [. . . ] Subject to change · All rights reserved Manufactured for and on behalf of the Environment and Combustion Controls Division of Honeywell Technologies Sàrl, Ecublens, Route du Bois 37, Switzerland by its Authorised Representative Honeywell GmbH [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL DU144

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL DU144 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag