User manual HONEYWELL EW447 DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HONEYWELL EW447. We hope that this HONEYWELL EW447 user guide will be useful to you.

Lastmanuals help download the user guide HONEYWELL EW447.


Mode d'emploi HONEYWELL EW447
Download
Manual abstract: user guide HONEYWELL EW447DATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] FOR HEATING AND COOLING APPLICATIONS PRODUCT DATA EW447-EW452 Series Mechanical Heat Meters Application Static compact heat meter with electronic measurement, consisting of electronic energy integrator and mechanical volume measuring component. Metering of hydronic heating and / or cooling energy in hydronic systems based on volume, supply and return temperature. EW447-EW449 models are suitable for energy metering of heating systems. [. . . ] The meter can be conveniently read from a single line seven-digit display with units and symbols. A pushbutton provides user friendly control of the various display loops. All failures and faults are recorded automatically and displayed on the LCD screen. To protect the reading data, all relevant data is saved in a non-volatile memory (EEPROM). This memory saves the measured values, device parameters and types of error at regular intervals. Mechanical volume measuring component The technology of the volume measuring component permits very high measuring accuracy and can be used in the supply or return pipeline. The volume measuring component meets the requirements of EN1434 / class 2 and 3. Supply voltage: · Lithium battery 3. 0 V DC (10-year life) EN0H-2601GE25 R0809 2 Honeywell Subject to change EW447-EW452 SERIES MECHANICAL HEAT METERS Ordering Information Table 3. Available versions and OS-Nos (OS=Ordering Specification) Size qp Size DN Length Connection Interface OS-No. (heating only) EW447A0100 EW447A1200 EW447A2000 EW448A2800 EW448A3600 EW448A4600 EW449A5100 EW449A5900 EW449A6900 EW449A7700 OS-No. (cooling and heating) EW450A0100 EW450A1200 EW450A2000 EW451A2800 EW451A3600 EW451A4600 EW452A5100 EW452A5900 EW452A6900 EW452A7700 0. 6 m3/h 1. 5 m3/h 2. 5 m3/h 3. 5 m3/h 6. 0 m3/h 10 m3/h 15 m3/h 25 m3/h 40 m3/h 60 m3/h DN15 DN15 DN20 DN25 DN25 DN40 DN50 DN65 DN80 DN100 110 mm 110 mm 130 mm 260 mm 260 mm 300 mm 270 mm 300 mm 300 mm 360 mm G 3/4 B G 3/4 B G1B G 1 1/4 B G 1 1/4 B G2B Flanges PN16 Flanges PN16 Flanges PN16 Flanges PN16 None None None None None None None None None None With M-Bus output 0. 6 m3/h 1. 5 m3/h 2. 5 m3/h 3. 5 m3/h 6. 0 m3/h 10 m3/h 15 m3/h 25 m3/h 40 m3/h 60 m3/h DN15 DN15 DN20 DN25 DN25 DN40 DN50 DN65 DN80 DN100 110 mm 110 mm 130 mm 260 mm 260 mm 300 mm 270 mm 300 mm 300 mm 360 mm G 3/4 B G 3/4 B G1B G 1 1/4 B G 1 1/4 B G2B Flanges PN16 Flanges PN16 Flanges PN16 Flanges PN16 M-Bus M-Bus M-Bus M-Bus M-Bus M-Bus M-Bus M-Bus M-Bus M-Bus EW447M0100 EW447M1200 EW447M2000 EW448M2800 EW448M3600 EW448M4600 EW449M5100 EW449M5900 EW449M6900 EW449M7700 EW450M0100 EW450M1200 EW450M2000 EW451M2800 EW451M3600 EW451M4600 EW452M5100 EW452M5900 EW452M6900 EW452M7700 With pulse output 0. 6 m3/h 1. 5 m3/h 2. 5 6. 0 m3/h m3/h 3. 5 m3/h 10 m3³/h 15 m3/h 25 m3/h 40 m3/h 60 m3/h DN15 DN15 DN20 DN25 DN25 DN40 DN50 DN65 DN80 DN100 110 mm 110 mm 130 mm 260 mm 260 mm 300 mm 270 mm 300 mm 300 mm 360 mm G 3/4 B G 3/4 B G1B G 1 1/4 B G1 1/ 4 Pulse output Pulse output Pulse output Pulse output Pulse output Pulse output Pulse output Pulse output Pulse output Pulse output B EW447P0100 EW447P1200 EW447P2000 EW448P2800 EW448P3600 EW448P4600 EW449P5100 EW449P5900 EW449P6900 EW449P7700 EW450P0100 EW450P1200 EW450P2000 EW451P2800 EW451P3600 EW451P4600 EW452P5100 EW452P5900 EW452P6900 EW452P7700 G2B Flanges PN16 Flanges PN16 Flanges PN16 Flanges PN16 Operation The integrator display has two loops. · Main loop · Service loop The main loop is configured to display the data for current energy and energy on reading date. The service loop displays the current data for flow rate, temperatures, power, volume and next reading date. A button is mounted on the front panel of the meter. This can be pressed for a short or long time. A short press of the button (< 3 seconds) switches to the next display within a loop and a long press (> 3 seconds) switches between the display loops. [. . . ] Pressure drop diagram EW447-EW452 Series Environmental and Combustion Control Honeywell GmbH Hardhofweg 74821 Mosbach, Germany Phone: +49 (6261) 810 Fax: +49 (6261) 81393 www. honeywell. com EN0H-2601GE23 R0809 August 2009 © 2009 Honeywell International Inc. Subject to change without notice Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell Technologies Sàrl, Rolle, Z. A. La Pièce 16, Switzerland or its authorized representative. 10 mbar 1000 Pa Pressure loss 2 3 4 5 6 7 8 9 100 10000 2 3 4 5 [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL EW447

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL EW447 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag