User manual HONEYWELL EXCEL 12

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HONEYWELL EXCEL 12. We hope that this HONEYWELL EXCEL 12 user guide will be useful to you.

Lastmanuals help download the user guide HONEYWELL EXCEL 12.


Mode d'emploi HONEYWELL EXCEL 12
Download

You may also download the following manuals related to this product:

   HONEYWELL EXCEL 12 DATASHEET (949 ko)
   HONEYWELL EXCEL 12 GUIDE D INSTALLATION (881 ko)
   HONEYWELL EXCEL 12 FCU PLUS LIGHT DATASHEET (967 ko)
   HONEYWELL EXCEL 12 FCU PLUS 4 LIGHTS DATASHEET (951 ko)
   HONEYWELL EXCEL 12 FCU PLUS LIGHT PLUS SUNBLIND DATASHEET (1024 ko)

Manual abstract: user guide HONEYWELL EXCEL 12

Detailed instructions for use are in the User's Guide.

[. . . ] Excel 12 W7704 HONEYWELL EXCEL 5000 OPEN SYSTEM INSTALLATION INSTRUCTIONS GENERAL INFORMATION Depending on your application's hardware requirements, you can choose between the following different Excel 12 models: Table 1. Overview of Excel 12 models AI1 (NTC20k + V) AI5 (NTC20k + V) AI7 (NTC20k + V) wall module LED output AO1 (0. . . 10 Vdc) AO2 (0. . . 10 Vdc) AI3 (fan speed / bypass) AI2 (NTC20k) W7704A1004*1 W7704B1002* W7704C1000* W7704D1008 W7704D1016 W7704F1003* * 1 12 1 1 X X X X X X X X XXXXXXXXXXXXXX XXXXXXXXXXXXXXXX XXXX XXXXXX XXXXXXXXXXXXXXX XXXXXXXXXXXXXXXX XXXXXXXXX X X X X X XX XX XX XX XX X X X X X XXXXXX XXXXXX XXXXXX XXXXXX XXXXXX XXXX * These hardware versions have been discontinued. 2 * The hardware variant W7704F1003 is cost-optimized for light control and does not support hardwired wall modules. BEFORE INSTALLATION Protection against shock: Software class: IMPORTANT It is recommended that the Excel 12 be kept at room temperature for at least 24 hours before applying power; this is to allow the evaporation of any condensation resulting from low shipping / storage temperatures. Class 0 (without terminal covers) Class II (with terminal covers) Class A Classification according to EN60529 (Degree of Protection Provided by Enclosures) Without terminal covers: IP20 With terminal covers: IP30 CAUTION To avoid electrical shock or equipment damage, you must turn off the power supply before attaching / removing connections to/from any terminals. Ambient Environmental Limits Operating temperature: Storage temperature: 0 . . . +70 °C at 5. . . 90% r. H. Approvals, Certifications, and Standards Approvals and Certifications CE-approved EUBAC-certified as follows: W7704D1008, W7704D1016 Temperature CA W7704D1016: W7704D1008: eu. bac Cert eu. bac Cert 020893 020896 Classification according to EN60730-1 Environmental conditions: Pollution degree: Chilled ceiling: 0. 5 K Electric convector: 0. 3 K Electric floor heating: 1. 2 K Radiator heating: 0. 5 K FCU heating mode: 0. 4 K FCU cooling mode: 0. 2 K (min. [. . . ] separation of 3 inches (76 mm) between such cables. Local wiring codes may take precedence over this recommendation. IMPORTANT Try to avoid installing in areas of high electromagnetic noise (EMI). The unit must be wired to the LONWORKS network using level IV 22 AWG (Belden part number 9D220150) or plenum-rated level IV 22 AWG (Belden part number 9H2201504) nonshielded, twisted-pair, solid-conductor wire. When possible, use Honeywell AK3781, AK3782, AK3791, or AK3792 cable (US part nos. ). See Excel 50/5000 LonWorks Mechanisms, EN0B-0270GE51, for details, including max. The unit is connected to the LONWORKS network as shown in Fig. 9 via terminal pins 3 and 4 (black screw-type T terminal plug) underneath the terminal protection cover (if present) located on the low-voltage side. Terminal 24 and 25 are used to connect further devices to the LONWORKS network. Connection of CO2-Sensor A CO2-sensor (e. g. C7110D1009) may be connected to analog inputs 1, 5, or 7 for air-quality control. W7704 TEMP. SENSOR BYPASS / FAN COMMON 9 10 11 12 13 14 15 16 24V ~ 22 24V 0 23 LON 1 24 LON 2 25 LED OUT 24 VAC CO2 IN Excel 12 24V ~ 24V 0 2 LON 1 3 LON 2 4 1 2 3 4 TEMP. SETPOINT 6 7 1 BYPASS / FAN 24V ~ 22 24V 0 23 LON 1 24 LON 2 25 COMMON CO2 OUT 24 VAC LED IN Excel 12 24V ~ 1 24V 0 2 LON 1 3 LON 2 4 C7110D Fig. Connection to LonWorks (fixed terminals) Depending upon the chosen network configuration, one or two terminations (see section "LONWORKS Termination" on page 7) may be required. LonWorks Communications The Excel 12 is equipped with a free-topology transceiver (FTT10A) for communicating on LONWORKS® networks. The LONWORKS network is insensitive to polarity, eliminating the possibility of installation errors due to miswiring. Different network configurations (daisy-chain, loop, and star configurations, or any combination thereof) are possible (see also Excel 50/500 LONWORKS Mechanisms Interface Description, EN0B-0270GE51). All Excel 12 controllers feature a LONWORKS service LED and service button (see section "Troubleshooting" on page 6). General Information Inputs/Outputs Use a min. of 14 AWG (2. 5 mm2) for all input/output connections. length of all input/output cables is 1300 ft (400 m). Two wires with a total thickness of 14 AWG can be twisted together and connected using a wire nut (include a pigtail with this wire group and attach the pigtail to the individual terminal block). Deviations from this rule can result in improper electrical contact. Local wiring codes may take precedence over this recommendation. Wire to the terminal blocks as follows: Wiring the Inputs/Outputs 5 EN1B-0201GE51 R0110F EXCEL 12 MODULES 1. Insert it at the required terminal location, and tighten the screw to complete the termination. [. . . ] LED flashes at power-up, goes OFF, then comes ON solid. Afterwards, the service LED turns ON and remains ON, indicating completion of the blanking process. Afterwards, the service LED turns ON and remains ON. OFF duration is 1. . . 15 sec, depending on the application size and the system clock. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL EXCEL 12

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL EXCEL 12 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag