User manual HONEYWELL FK06-AAM

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HONEYWELL FK06-AAM. We hope that this HONEYWELL FK06-AAM user guide will be useful to you.

Lastmanuals help download the user guide HONEYWELL FK06-AAM.


Mode d'emploi HONEYWELL FK06-AAM
Download
Manual abstract: user guide HONEYWELL FK06-AAM

Detailed instructions for use are in the User's Guide.

[. . . ] Please take note that any assembly, commissioning, servicing and adjustment work may only be carried out by authorized persons. Immediately rectify any malfunctions which may influence safety. Housing with pressure gauge connections on both sides · threaded connections · Valve insert complete with diaphragm and valve seat · Pressure gauge not included (see accessories) AAM = with clear filter bowl, threaded union connectors, filter mesh size 100 µm with brass filter bowl, threaded union connectors, filter mesh size 100 µm During normal operation, water flows through the filter mesh to the body outlet. [. . . ] Discharge into floor drain Filter size 3/4" - 1 1/4" Reverse rinsing quantity* C (mm) 25 litres 20 *at 4, 0 bar inlet pressure and a rinse duration of 15 seconds MU1H-1126GE23 R0609 6 Honeywell GmbH O If the pressure is increasing slowly, the valve may be dirty or defective. In this instance, carry out servicing and cleaning 3. Close shutoff valve on inlet Release pressure on outlet side (e. Through water tap) Close shutoff valve on outlet Loosen slotted screw o Do not remove slotted screw Slacken tension in compression spring o Turn control handle to the left (-) until it does not move any more Slowly open shutoff valve on inlet Turn control handle until the setting scale shows the desired value Retighten slotted screw Slowly open shutoff valve on outlet We recommend a planned maintenance contract with an installation company 1 Pressure reducing valve Frequency: every 1-3 years (depending on local operating conditions) To be carried out by an installation company 1. Loosen slotted screw o Do not remove slotted screw Caution !Slacken tension in compression spring o Turn control handle to the left (-) until it does not move any more o Do not turn in too far!Remove valve insert with a pair of pliers 9. Check that sealing ring, edge of nozzle and slotted ring are in good condition, and if necessary replace the entire valve insert 12. Reassemble in reverse order Press in diaphragm with finger before inserting slip ring Screw in filter bowl hand-tight (without tools) 13. In accordance with DIN 1988, part 8, the following measures must be taken: 1 Filter Frequency: at least every 2 month (depending on local operating conditions · Non-compliance can lead to the filter becoming blocked This results in a drop in pressure and decreasing water flow · the filter meshes are made of stainless steel. A red coating as a consequence of rust from the pipelines has no influence on function or the way the filter works To be carried out by an installation company or the operator. Filtered water can be drawn during rinsing. If rinsing is into a container, then a suitable container must first be put underneath. Open the ball valve by turning the rinse knob o Rinse knob must be vertical 2. [. . . ] Dezincification resistant brass housing Brass threaded connections High-quality synthetic material valve insert High-quality synthetic material spring bonnet with adjustment knob and setting scale Spring steel adjustment spring Stainless steel fine filter Red-bronze or shock-resistant, clear transparent synthetic material filter bowl Fibre-reinforced NBR diaphragm NBR seals Observe the local requirements regarding correct waste recycling/disposal!Problem Beating sounds Water is escaping from the spring bonnet Too little or no water pressure Cause Filter combination is toolarge Diaphragm in valve insert is faulty Shutoff valves upstream or downstream from filter not fully open Filter combination is not set to the desired outlet pressure Filter mesh dirty Not fitted in flow direction Remedy Call our Technical Customer Services Replace valve insert Open the shutoff valves fully Set outlet pressure Clean or replace filter Fit filter in flow direction (note direction of arrow on housing) Clean or replace filter Replace valve insert The outlet pressure set does not remain constant Filter mesh dirty Valve insert, sealing ring or edge of nozzle is contaminated or worn Rising pressure on outlet (e. Description 1 2 3 Spring bonnet complete Valve cartridge complete (without filter insert) Seal ring set (pack of 10) 1" 11/4" 4 5 Blanking plug with O-ring R1/4" (pack of 5) Clear filter bowl complete with filter and carrier body O-ring-set for carrier body (pack of 10) Replacement filter insert O-ring-set for filter bowl (pack of 10) Double ring wrench For removing filter bowl (no fig. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL FK06-AAM

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL FK06-AAM will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag