User manual HONEYWELL HCC80R DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HONEYWELL HCC80R. We hope that this HONEYWELL HCC80R user guide will be useful to you.

Lastmanuals help download the user guide HONEYWELL HCC80R.


Mode d'emploi HONEYWELL HCC80R
Download
Manual abstract: user guide HONEYWELL HCC80RDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] HCE80/HCC80/HCE80R/HCC80R UNDERFLOOR HEATING-ZONEING CONTROLLERS PRODUCT DATA GENERAL The underfloor heating-zoning controllers are used for individual room temperature control. The applications are underfloor heating and radiator control as well. [. . . ] Up to 3 controllers can be connected to one antenna. The controllers HCE80/HCE80R are connected with the external antenna HRA80. The controllers HCC80/HCC80R include the antenna on the circuit board. The antenna includes also the transceiver 868, 3MHZ. Because of the new wiring concept the thermal actuators can be installed very fast and pre wired without screws. Cooling applications are also possible by switching from heating into the cooling mode with potential free change over contact. Note: The controllers HCE80/HCC80/HCE80R and HCC80R have the same functionality exception the output for the boiler feedback. HCE80/HCC80: Analogue output for OTC controllers MCR, Panther, Smile (additional boiler relay not available) HCE80R/HCC80R: Additional boiler relay 42V (analogue output for OTC controllers is not available FEATURES · Easy and fast installation because the new wiring design · Pluggable terminals for fast wiring connection because clamp contacts · Integrated pump relay for pump control Relay (230V AC non potential free contact) · Integrated antenna for the controllers HCC80 and HCC80R only · External antenna for HCE80 and HCE80R only · Up to 3 controllers can be connected to one antenna external HRA80 or integrated antenna · Basic 5 configuration 5 zones · Easy extendable with HCS80 for up to 8 zones · Central operating via HCM200D / CM67z possible · LED indication for voltage, operation mode, status and errors, RF check · Outputs for a maximum of 24 thermal actuators · Analogue output for boiler feedback to MCR200 / MCR40/ Panther / Smile (only HCE80/HCC80) · Boiler control with integrated boiler relay potential free contact 42V (only HCE80R and HCC80R) · Boiler feedback in dependence of valve setting with HC60NG possible · Switchable between normally closed/open thermal actuators · Potential free switch over contact heating / cooling EN0H0501GE51 R0805 HCE80/HCC 80. . /R SPECIFICATIONS Electrical Voltage supply Power consumption : 230 V AC, 50 Hz + 10 % / -15 :max. 1750 VA with connected Pump6A) max180 VA without pump : 42 Volt potential contact, 6A : Ceramics safety fuse 230 VAC, 2, 5 A swift, 5 x 20 mm : Expansion module HCS80 enhance the controller to 8 zones RF COMMUNICATION RF band : 868, 3 MHz Transceiver (integrated in the antenna) Integrated pump relay Safety fuse The external HRA80 includes the transceiver used for HCE80 and HCE80R HCC80 and HCC80R includes the antenna and transceiver on the circuit board Receiver class :2 RF communication range : 30m in a residential building environment RF communication : short, high rate transmission to minimize air time and avoid collisions Technology Optional Wiring Admissible cable types and lengths : Thermal actuators Cable diameter Cable length Cable cross-section Strip length Outside cable diameter Cable length Cable cross-section Strip length Antenna Cable length Cable cross-section / type Max. 30 m JE-LiYCY 2x2x0. 8 mm²; JE-Y(St)2Y 2x2x0. 8 mm²; 2 x 0. 5 mm² Heating / Cooling, Boiler feedback Cable length Cable cross-section / type Max. 100 m JE-LiYCY 2x2x0. 8 mm²; JE-Y(St)2Y 2x2x0. 8 mm²; 2 x 0. 5 mm² Min. 1. 5 mm² 7 mm ENVIRONMENTAL and STANDARDS Mounting Measurements (WxHxD) Protection class Operating temperature Storage temperature Relative humidity Fire protection class Authorization : Wall mounting or DIN track : 350 x 52 x 82 mm : IP 30 : 0. . . +50 °C : -20. . . . . . +70 °C : max. [. . . ] Printed in Germany EN0H0501GE51 R0805 Manufacturing location certified to . in t m p tp o te Se om Ro HR80 · Analogue Boiler feedback OTC controller MCR/Panther/Smile (HCE80/HCC80) only · Boiler feedback relay potential free contact 42V (HCE80R/HCC80R) only · Thermal actuator up 24 (MT4-230) · Change over contact heating/cooling Underfloor heating controller HCE80/HCE80R/HCC80/HCC80R [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL HCC80R

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL HCC80R will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag