User manual HONEYWELL KALTECCOOL PW60A-B

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HONEYWELL KALTECCOOL PW60A-B. We hope that this HONEYWELL KALTECCOOL PW60A-B user guide will be useful to you.

Lastmanuals help download the user guide HONEYWELL KALTECCOOL PW60A-B.


Mode d'emploi HONEYWELL KALTECCOOL PW60A-B
Download
Manual abstract: user guide HONEYWELL KALTECCOOL PW60A-B

Detailed instructions for use are in the User's Guide.

[. . . ] Please take note that any assembly, commissioning, servicing and adjustment work may only be carried out by authorized persons. Immediately rectify any malfunctions which may influence safety. External transformer; the device is only fed with a protective low voltage of 24 V · Two armoured hoses with matching piece to DA74C In order to protect the device against foreign particles, it must only be installed with an upstream fine filter (recommended by Honeywell FK74C) In case of high inlet pressure (> 6 bar) a pressure reducer must be installed in upstream A drain connection within five meters distance or two meters height must be available. The drain hose must not be kinked in any way as this will lead to an overflow of the device. [. . . ] Impurities and soldering remains are flushed out of the pipework. Noise development can occur during regeneration due to incomplete deaerating. However, this will disappear after 2-3 regenerations!Determine the water hardness on the inlet side (using the enclosed hardness measuring instruments) o Sample water from the sample tap on the connecting set, or set the water conditioning device to "bypass" position and extract a water sample from the first tapping point 2. Flushing takes place via the drain tube during regeneration!Function keys Start the manual regeneration Programming Adjusting displayed value downwards Adjusting displayed value upwards Indicator lamps Chlorine generation (function not active) Holiday Mode active Setting the water hardness Setting the capacity of the system* Setting the time for regeneration at night* Power indicator During operation the time alternates with the remaining volume on the display. during the usage of water the remaining volume (only treated part) decreases to zero. Afterwards ­ every 4 days, however, the latest ­ a manual regeneration is actuated. With PW 60-A phase 6 is not separately indicated. Device can be set into a Holiday Mode, i. If no water has been drawn off 4 days after the last regeneration a new regeneration is started. As soon as water is drawn off again the device stops the regeneration. In order to set the time press arrow keys In order to set the water hardness press the key for 5 seconds, set hardness via arrow keys and and store entry by pressing the key again. Every 4 weeks The system needs to be filled up if the magnesium level has dropped below the "Min"-mark. Use a complete bag of VC51-A to fill up. A manual regeneration can be actuated at any time, even if the remaining volume has not reached zero yet. In order to quickly jump to the next phase during the regeneration press the key. Working method during power failure In case the power supply is interrupted for a longer period of time it is recommended to set the device to bypass position for the time of power failure. In accordance with the directive DIN 1988 the device must be maintained regularly, normally at least once a year. honeywell provides suitable Maintenance-Sets. [. . . ] 5) Water pressure reduction / slowly Pipework of the drinking water supply Clean or replace the pipework decreasing effectiveness is calcified or blocked Control valve is contaminated or de- Clean control valve or, if necessary, refective place control head (CS*) Water meter is contaminated or defec- Clean and, if necessary, replace water tive meter (CS*) Increasing iron deposit in the resin Exchange resin (CS*) Too much water in the storage Brine tube is contaminated Clean brine tube tank Drain tube is blocked Clean and, if necessary, replace drain tube Incorrect settings at the control valve Check the control valve settings Brine valve is contaminated or defecti- Clean and, if necessary, replace brine ve valve (CS*) Magnesium build up in cabinet May be caused by temperature fluctu- Pour a cup of hot water over the lumps ations in the cabinet and keep stirring, until all lumps have disappeared Formation of brown sediment in Normal excretions from consumables Remove when cleaning the storage tank Time is flashing Device suffered a power failure Reset the clock (has no effect on the function) Incorrect display , , H----25" Operating program has been deleted Call Technical Customer Service Irregular removal of magnesium Magnesium is initially dissolved in the Before refilling, move the undissolved in the cabinet, "magnesium accu- centre of the cabinet, near the brine magnesium to the middle of the cabimulation" on cabinet wall pipe net, using a spoon or similar. Then fill in new magnesium salt Extremely high salt consumption Control orifice got stuck Correct the position of the control orifice or replace the complete adapter. D06F Pressure reducing valve Noise protected pressure reducing valve with setting scale. Maximum inlet pressure 16 bar, with brass filter bowl 25 bar, outlet pressure range 1. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL KALTECCOOL PW60A-B

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL KALTECCOOL PW60A-B will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag