User manual HONEYWELL KALTECSOFT KS10S

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HONEYWELL KALTECSOFT KS10S. We hope that this HONEYWELL KALTECSOFT KS10S user guide will be useful to you.

Lastmanuals help download the user guide HONEYWELL KALTECSOFT KS10S.


Mode d'emploi HONEYWELL KALTECSOFT KS10S
Download
Manual abstract: user guide HONEYWELL KALTECSOFT KS10S

Detailed instructions for use are in the User's Guide.

[. . . ] Using the integrated consumption counter the microprocessor calculates the individual consumption characteristics and the remaining capacities resulting thereof as well as the optimal time for the regeneration. At the latest 4 days after the last regeneration the next regeneration is initiated (independent of the water consumption). if 97 % of the calculated capacity has been reached , a regeneration is initiated independently of the 4-day interval. [. . . ] F762) should be installed no more than 1 metre ahead in flow direction of the softening device to protect the plant. â· The following is needed for operation in the close vicinity of the device: o a channel interface (at least DN50) o separate mains connection (230 V / 50 Hz) o Floor drain 8. To avoid irreplaceable damages on the softening device, all welding and soldering work in the near vicinity should be completed before the mounting. Put diluting device into bypass position o close the two outer valves o open the middle valve 2. Put diluting device into operating position o Slowly open the input valve completely o Slowly open the output valve completely o Close middle valve 4. Pour salt tablets into the salt supply container Use only salt tablets acc. Connect transformer to the device o Remove cover to the salt container and hood o Plug the cable shoes of the transformer into the controller 8. Replace hood and cover, guide the cable out of the back of the device 9. Starting regeneration o Press the Regeneration key for 5 seconds o Display Regeneration active flashes o The time is displayed in the display during the regeneration process After the end of the regeneration (duration 45 minutes) o Display Regeneration active goes out. There is a connection to the power supply o Display Current time flashes Set the raw water hardness by pressing + or The hardness of the raw water can be inquired from the water distribution company. Setting the mix water hardness by turning the screw at the base of the diluting device o Use screwdriver o Turn counter-clockwise = increase water hardness on output side o Turn clockwise = decrease water hardness on output side 2. check the mix water hardness at a tapping point o Open tapping point completely to ensure sufficient flow 3. Readjust by turning the screw if necessary Press the REGENERATION key for 5 seconds o Display Regeneration active flashes o Continue with point 2 to 11 chapter 10. 2 The settings, excluding the time remain intact, but need to be confirmed with MENU / OK . The regeneration needs to be carried out to return to the normal operating mode. In compliance with European and national norms (e. Maintenance work should only be carried out be qualified staff!The following maintenance work needs to be carried out: 12. [. . . ] Detergents must not be allowed to enter the environment or the sewerage system!Clean the housing with water and a cloth inside and out 11. 1 Power Failure: Brief power failure: All settings including the time remain intact After longer power outage: o Display Current time flashes Problem No water supply to the device Cause Shut-off device in the bypass is not open or only partially open Remedy Open shut off valve fully Pipework of the drinking water supply Clean or replace the pipework is calcified or blocked Device does not regenerate Flow meter is defective Internal electric cabling is defective Check and, if necessary, replace the flow meter (CS*) Check internal electric cabling (CS*) Wrong connection of connecting hoses Connect the flexible connection lines correctly Rotary disc valve defective Nothing is displayed Incorrect time is displayed Insufficient function Power supply has been interrupted Rotary disc valve defective Power failure occurred Device not deaerated Call Technical Customer Service Check power suppy (mains plug, fuse) Call Technical Customer Service Set the time Deaerate device Storage tank is almost or completely Check salt level empty Blending has been set incorrectly Control valve is contaminated or defective CS = Customer services tel. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL KALTECSOFT KS10S

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL KALTECSOFT KS10S will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag