User manual HONEYWELL PCR 300

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HONEYWELL PCR 300. We hope that this HONEYWELL PCR 300 user guide will be useful to you.

Lastmanuals help download the user guide HONEYWELL PCR 300.


Mode d'emploi HONEYWELL PCR 300
Download

You may also download the following manuals related to this product:

   HONEYWELL PCR 300 DATASHEET (284 ko)

Manual abstract: user guide HONEYWELL PCR 300

Detailed instructions for use are in the User's Guide.

[. . . ] PCR-300 PCR-300 RC Installation and Operating Instructions Electronic refrigeration control EB-PCR-04 EN1H-1924GE23 R1207 TABLE OF CONTENTS 11 Unpacking the unit and conditions of use 12 General instructions 13 Use and function 3. 1 Use for the purpose intended 3. 2 Function 3 3 3 3 4 4 4 5 5 5 6 8 9 9 9 10 11 11 11 12 13 13 15 16 16 17 17 18 14 Safety 4. 1 Sources of danger 4. 2 Safety precautions 15 Installation and commissioning 5. 1 Mechanical installation 5. 2 Electrical installation 5. 3 Setting the DIP switch for the emergency setpoint and clock back-up battery 16 Operating of the controller 6. 1 6. 2 6. 3 6. 4 6. 5 Switching on the operating voltage Display Key functions Adjusting the cold store temperature Changing the cold store temperature difference, defrost cycle, and alarm temperature 6. 6 Setting the time (PCR-300RC only) 6. 7 Manual defrost 7. 1 Input parameters and ranges 7. 2 Sensor calibration (parameters E 15 and E 16) 17 Programming 18 Maintenance 19 Alarm messages 10 Problem solving 11 Conditions of warranty 12 Technical data 2 1 Unpacking the unit and conditions of use Before and when unpacking the unit, make a visual inspection to identify any possible damage which may have occurred during transportation. Please look for loose parts, dents, scratches, etc. Report any damage immediately to the freight company. (Please see "Conditions if damage has occurred". ) In other cases, the latest edition of the "General conditions for the supply of goods and services" issued by the ZVEI (German Central Association for the Electrotechnical Industry) shall apply. [. . . ] (The battery is switched off when the controller is delivered; exhaustive discharge monitoring). Pos. : on (top): Battery activated. 8 ¼ Note: It takes approximately 24 hours for the battery to achieve its full back-up capacity. The battery will provide cover for a power failure of approximately 1 month. 6 Operation of the controller Front view of controller: 6. 1 Switching on the operating voltage The controller is started by means of a control switch provided by the customer. The first time the controller is started, pre-programmed setting values are used which at later point can be adapted for individual requirements. If alarm "AL 2" (temperature in refrigerated chamber too high or too low) is displayed when the controller is switched on, this can be cleared by pressing the key. 6. 2 Display During normal operation the current cold store temperature is displayed. It is measured with cold store sensor T1. In the event of an alarm, the most recent alarm message (e. g. AL1) and the cold store temperature are displayed alternately. 9 Three spot indicators show the switching status of the relays during operation: Pos. Flashes: Compressor start-up delay E05 active. 6. 3 Key functions Never operate the keys with sharp objects (screwdriver or similar). Display of setpoint temperature Clear alarm messages Evaporator temperature display Manual defrost initiation Display of time until the next defrost Display limit value for excess temperature alarm (cold store sensor T1) ¼ ¼ ¼ Press and hold down key. Press key. (If the sensor is faulty, switch mains voltage ON/OFF. ) Press and keys in sequence and hold both down. Press key for 5 secs. Press and keys in sequence and hold both down. (Display in hours and minutes. ) Press key. Change input values by using the and keys with the key pressed down. the switching difference, are indicated by "E" and a 2-digit number, e. g. The input parameters are grouped together in two programming levels. 10 ¼ ¼ Access the first programming level by pressing the and keys at the same time for 5 seconds. Then use the and keys to access the parameters to be changed. Access the second programming level by pressing the and and keys simultaneously for 5 seconds. To exit from the programming levels and save the data, press the key after the last input parameter. Caution: The times must be entered in ascending order. Exiting programming mode: Press the been entered. [. . . ] Evaporator temperature sensor T2 ­ short circuit or break in wiring. Safety times are used, for the fan run-on function the fan is controlled with the compressor by the evaporator fan control E11 automatically switching from 3 to 1. After sensor T2 has been repaired, E11 must be reset manually from 1 to 3. For PCR-300RC only: Real-time clock faulty, switching over to interval defrosting (interval = 4 hours)! AL2 AL3 AL4 AL5 AL6 AL7 16 Clearing alarm: Press the key. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL PCR 300

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL PCR 300 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag