User manual HONEYWELL Q7055B1047

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HONEYWELL Q7055B1047. We hope that this HONEYWELL Q7055B1047 user guide will be useful to you.

Lastmanuals help download the user guide HONEYWELL Q7055B1047.


Mode d'emploi HONEYWELL Q7055B1047
Download
Manual abstract: user guide HONEYWELL Q7055B1047

Detailed instructions for use are in the User's Guide.

[. . . ] Advanced features like graphics, trends and reports give enhanced flexibility and total control when accessing the Building Management System from a remote location. Customers can now gain the advantages of high-performance network and services, including traffic management, to more locations throughout the network. TCP/IP OVN OVN SINGLE C-BUS (ONLY FOR XL5000 CONTROLLERS FAMILY) SINGLE C-BUS (ONLY FOR XL5000 CONTROLLERS FAMILY) M25198 Fig. The Q7055B1047 OVN Server is used in systems for signaling in energy management systems (UL 916). In addition, the following standards apply: requirements of Canadian province and local building codes; CEC 22. 1 Canadian Code. 95-7711 Q7055B1047 OPEN VIEW NET SERVER (OVN) SPECIFICATIONS Models: Q7055B1047 Open View Net Server (OVN). [. . . ] · Building Network Adapter driver software CD. Tx Test LAN 10 100 ACT M25117 Fig. Single server operating position. 95-7711 2 Q7055B1047 OPEN VIEW NET SERVER (OVN) Wall Mounting It is also possible to mount the OVN server to a wall. The following sequence describes how the server should be prepared prior to mounting it on a wall (see Fig. 3). Communications Panel Mounting It is also possible to mount the OVN Server in the 14006090-555151 series EBI Communications Panel (Refer to Fig. 4). Place the OVN server with the topside down on the desk. Rx Tx LAN 10 100 100 100 100 100 ACT ACT ACT ACT ACT Remove the four feet from the bottom of the OVN by pushing horizontally away from the housing with a flat screwdriver. Rx Tx LAN LAN LAN LAN 10 10 10 10 Push the four inserts (included) fully and horizontally into the housing. Rx Tx Tx Tx Adjust the four retaining clips (included) on top of the inserts. Fasten the retaining clips with the included four screws. Rx Use the housing with the clips to mark the positions of the four mounting holes on the wall surface. (4 mm) holes for the mounting screws (not included) and secure the OVN server. Fig. OVN wall mount. Rx M25121 3 95-7711 Q7055B1047 OPEN VIEW NET SERVER (OVN) WIRE PER NEC FOR FIRE ALARM 2 3 H TRIPP-LITE NG 6 4 6 G F D OVN G F D 1 4 5 2 OVN NON-POWER LIMITED AREA 1 2 3 4 5 6 POWER LIMITED AREA TYPICAL MOUNTING LOCATIONS FOR 14005680-089582/592 FIBER OPTIC INTERFACE. ALL WIRING MUST BE IN ACCORDANCE WITH NFPA 70, NATIONAL ELECTRICAL CODE AND ALL APPLICABLE LOCAL CODES. G = GROUNDING CONDUCTOR GROUND CONNECTION. GROUND CONNECTION FOR 14507678 SERIES PNET PROTECTOR AND OTHER LOW VOLTAGE EQUIPMENT. DRILLED MOUNTING HOLES FOR 14507719-001 8 PORT ETHERNET HUB (IF USED). NOTE: SYSTEM WIRING IS CLASSIFIED AS EITHER POWER LIMITED OR NON-POWER LIMITED PER NEC ARTICLE 760. ALL POWER LIMITED WIRING MUST BE SEPARATED FROM ALL NON-POWER LIMITED WIRING BY A MINIMUM DISTANCE OF 1/4 IN. Typical mounting of Q7055B1047 OVN Assembly on 14006090-555151 series Communication Panel. 95-7711 4 Q7055B1047 OPEN VIEW NET SERVER (OVN) CONNECTIONS This section describes how to connect power and the field bus to the OVN server. A supply pack with installation material containing the required connectors for power and the field bus are shipped with the server. CABLES AND CONNECTORS DB9F Null-Modem Connector See Fig. 5 for serial connectors. Power Connection The OVN server requires an external power supply with the following specifications: 24 Vac, 50 Hz to 60 Hz, or 24 Vdc. Typical power supplies include: DC Power Supply: 50017367-001, Jameco Model No. DDU240050, 120 Vac, 60 Hz input, 24 Vdc, 0. 500 A output, wall mounted power cube, Class 2. FW7224-D5F, 120/240 Vac, 50/60 Hz input, 24 Vdc, 3. 0 A output. AC Power Supply: 120 Vac/50 to 60 Hz input, 24 Vac output, 14507287 series, 14507350-002, listed. Power consumption of the OVN server is 8 VA. For the power connection, the 3-pole Phoenix connector is required (included). [. . . ] 6--AC/DC IN 24 V Power connector for 24 Vac (50 Hz to 60Hz) or 24 Vdc power supplies and chassis ground. Power consumption is 8 VA (connected via 10/100BaseT, cable). Excel 5000 Open View Net Server rear panel. Enterprise Buildings Integrator (EBI)TM and Excel 5000TM are trademarks of Honeywell International, Inc. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL Q7055B1047

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL Q7055B1047 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag