User manual HONEYWELL Q7750A DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HONEYWELL Q7750A. We hope that this HONEYWELL Q7750A user guide will be useful to you.

Lastmanuals help download the user guide HONEYWELL Q7750A.


Mode d'emploi HONEYWELL Q7750A
Download
Manual abstract: user guide HONEYWELL Q7750ADATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] The Q7750A provides C-Bus (9600 baud and 1M baud) and LONWORKS® (78k baud) communication interfaces. It also maps user selectable Excel 10 subsystem datapoints into C-Bus points with a full set of point attributes, including user addresses. The Q7750A is available in two hardware versions: The Q7750A1005 has a twisted pair topology (TPT) LONWORKS® transceiver. [. . . ] 1 2 3 4 5 6 7 8 explanation 5V (POWER) Contr. (RUN) B-PORT (send) B-PORT (receive) C-Bus (send) C-Bus (receive) LONWORKS® Service LED color green green yellow yellow yellow yellow yellow red LED function if ON Power ON Software running, watchdog triggered Q7750A sends data on RS232 port* Data sent to Q7750A on RS232 port* Q7750A sends data on C-Bus* Q7750A receives data from C-Bus* LONWORKS® network activity* (see NOTE) Blinking not configured LED function if OFF Power OFF Watchdog locked, software not working No communication No communication No data sent on the C-Bus No data received from the C-Bus No LONWORKS® network activity LONWORKS® initialized and working correctly *LEDs 3 through 7 with the frequency of data being transmitted or received (see NOTE). NOTE: LED 7 is used to display LONWORKS® network activity. In the case of the C7750A1005, it flickers when data is transmitted or received, but in the case of the C7750A2003, it flickers only while data is being received. Communications Via LONWORKS® The Q7750A uses a transformer-coupled communications port with encoded data presented to controllers and devices on the LONWORKS® at 78K bits per second. The LONWORKS® is insensitive to polarity, eliminating installation errors due to miswiring. The maximum allowed number of nodes per LONWORKS® is 60. With the addition of a Q7751A Router, the maximum allowed number of nodes increases to 120 or 60 per LONWORKS® segment. The recommended wire for the LONWORKS® will level IV, 22 AWG (Belden part number 9D220150) or plenum rated Level IV, 22 AWG (Belden part number (H2201504) non-shielded, twisted pair, solid conductor wire. Honeywell LONWORKS® cable is available. See also Excel 10 Q7750A Zone Manager ­ Installation Instructions (95-7509). Additionally, Echelon approved shielded cable can be used. Technical Support for the recommended vendors of Echelon-approved cables. In the case of the C7750A2003: An FTT network can accommodate bus, star, loop or any combination of these topologies. This simplifies system installation and makes it easy to add nodes should the network need to be expanded In the case of the C7750A1005: The TPT LONWORKS® is a daisy chain topology - the bus must go serially from one controller to another without branching. The C7750A2003 can be used to replace the C7750A1005 using a TPT/FTT router. The maximum allowed length of an FTT network is dependent on a number of factors, see Excel 50/500/800 Lonworks Mechanisms ­ Interface Description (EN0B-0270GE51) or Excel 10 Q7750A Zone Manager ­ Installation Instructions (95-7509) for details. Via C-Bus The C-Bus transmits data between EXCEL 5000 System Controllers, Devices and Building Supervisors at 9600 baud or 1 Mbaud (921 600 baud). The maximum allowed C-Bus network length is 1200 m, but with the addition of an XD509 Excel High Speed Repeater, the C-Bus can be extended (an additional 1200 m for each XD509). The maximum allowed number of controllers or devices per C-Bus is 29. [. . . ] Approval Bodies The Q7750A1xxx is listed under UL 864 (UUKL), File Number S4804. The Q7750A meets FCC part 15 class B requirements. Electromagnetic: EN 50081-1, EN 500 82-1. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL Q7750A

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL Q7750A will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag