User manual HONEYWELL SG150

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HONEYWELL SG150. We hope that this HONEYWELL SG150 user guide will be useful to you.

Lastmanuals help download the user guide HONEYWELL SG150.


Mode d'emploi HONEYWELL SG150
Download

You may also download the following manuals related to this product:

   HONEYWELL SG150 DATASHEET (525 ko)

Manual abstract: user guide HONEYWELL SG150

Detailed instructions for use are in the User's Guide.

[. . . ] Please take note that any assembly, commissioning, servicing and adjustment work may only be carried out by authorized persons. Immediately rectify any malfunctions which may influence safety. 0 bar Subsequent alteration of the setting is not permitted and is impossible without destroying the security cap 40 °C Minimum pressure drop 1 bar Connection size Complete pressure reducer (only with SG150D) with fine screen (mesh opening 0. 16 mm) and clear sighted strainer cup · Safety groups of this type combine pressure reducing valve (only SG150D), check valve, shutoff valve, test point and diaphragm type safety valves in one appliance. [. . . ] ⷠIf, for compelling reasons, more elbows or a greater length becomes necessary, then the entire discharge line must be designed to a larger nominal width. More than 3 elbows, as well as lengths over 4m are not permitted! ⷠThe discharge line must be installed with an incline!Install safety group in the cold water line o Note flow direction o Install without tension or bending stresses 1 Setting outlet pressure Set outlet pressure min. Loosen slotted screw o Do not remove slotted screw 5. Slacken tension in compression spring o Turn control handle to the left (-) until it does not move any more 6. Turn control handle until the setting scale shows the desired value 8. DIN 1988, Part 8 specifies that the following operations be carried out regularly. 1 Pressure reducing valve Interval: once a year 1. Check back pressure using a pressure meter when there is zero through-flow o If the pressure is increasing slowly, the valve may be dirty or defective. In this instance, carry out servicing and cleaning 3. Open check valve o Until the pressure is released, some water will flow out of the check valve. After a short period of time the water flow should stop. If the water continues to drip or run, then the backflow preventer must be replaced - see servicing of backflow preventer 3. 3 Safety valve Frequency: every 6 month 1. Actuate lifting device multiple times, if necessary initiate repairs 9. 1 Pressure reducing valve Frequency: every 1-3 years (depending on local operating conditions) To be carried out by an installation company 1. Loosen slotted screw o Do not remove slotted screw Caution ! [. . . ] Detergents must not be allowed to enter the environment or the sewerage system!Screw in filter cup hand-tight (without tools) 8. High grade synthetic material pressure reducing valve insert, spring bonnet with adjuster knob, shutoff valves, test socket, check valve, safety valve insert and drain connector · Actuate lifting grip multiple times so that dirt particles are flushed out, or replace as necessary Backflow stopper does not close Pressure increase in the front pres- Replace backflow stopper off tightly in the front pressure sure area area. Seal surfaces dirty or worn Replace backflow stopper Too little or no water pressure Cut-off fixtures before or after the Open the shutoff valves fully safety group not opened entirely Safety group not installed in the flow Install safety group in flow direction direction (observe arrow direction on housing) only SG150D Water is escaping from the Diaphragm in valve insert is faulty Replace valve insert spring bonnet Too little or no water pressure Pressure reducing valve is not set to Set outlet pressure the desired outlet pressure Filter in pressure reducing valve is Clean or replace filter contaminated The outlet pressure set does not Filter in pressure reducing valve is Clean or replace filter remain constant contaminated or worn Valve insert, sealing ring or edge of Replace valve insert nozzle is contaminated or worn Rising pressure on outlet (e. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL SG150

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL SG150 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag