User manual HONEYWELL SG162

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HONEYWELL SG162. We hope that this HONEYWELL SG162 user guide will be useful to you.

Lastmanuals help download the user guide HONEYWELL SG162.


Mode d'emploi HONEYWELL SG162
Download

You may also download the following manuals related to this product:

   HONEYWELL SG162 DATASHEET (144 ko)

Manual abstract: user guide HONEYWELL SG162

Detailed instructions for use are in the User's Guide.

[. . . ] 1 Safety group SG 162 x Shut-off valve y Test screw for non return valve z Non return valve { Diaphragm safety valve with venting facility | Discharge tundish with rosette Hot water connection pipe with connectors and rosette ~ Bent connection tube with connectors and rosette 1. Install safety group into wall q Screw cold water inlet 1 into cold water supply 2 q Screw hot water outlet 3 into hot water distribution 4 . [. . . ] The safety group can be mounted right or left. For safety reasons, during heat-up water may discharge from the discharge pipe. Planned maintenance is recommended and DIN 1988, Part 8 specifies the following operations: 3. 1 Check Valve Testing The check valve must be tested once a year. Until the pressure has been relieved, a little water will emit from the test valve. Emission of water should stop after a few moments. If water continues to drip or run without stopping, then the check valve is either damaged or dirty. 2 Safety valve inspection To be carried out by user or specialist every six months: 1. Operation check by testing the safety valve function: Vent the valve during normal operation of the system. The discharged water should run away properly and the valve then fully shut off when released. If the valve does not function properly, venting several times may correct the situation. Visual inspection of the outlet pressure on a pressure gauge at zero flow and peak flow rate (large take off). [. . . ] Any variation from this or other use will not comply with requirements. All assembly work has to be carried out by authorized specialists. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL SG162

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL SG162 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag