User manual HONEYWELL SM180

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HONEYWELL SM180. We hope that this HONEYWELL SM180 user guide will be useful to you.

Lastmanuals help download the user guide HONEYWELL SM180.


Mode d'emploi HONEYWELL SM180
Download

You may also download the following manuals related to this product:

   HONEYWELL SM180 INSTALLATION INSTRUCTIONS (506 ko)

Manual abstract: user guide HONEYWELL SM180

Detailed instructions for use are in the User's Guide.

[. . . ] SM180 Diaphragm safety valve for solar systems Product specification sheet Application The membrane safety valves of this type are used as last safeguard for solar systems when the stipulated control and safety devices fail. They must therefore be capable to discharge the entire boiler output as steam in case of emergency. [. . . ] Construction The safety valve comprises: · · · · EN0H-1368GE23 R0609 · Änderungen vorbehalten Medium Water or glycol-water mixture, according to VDI 2035 Liquids of the fluid group 1 and 2 (pressure device guideline, item 9) which do not affect the materials used. Technical Data Installation position Opening pressure Horizontal with safety cap pointing up Factory preset to 2. 5, 3. 0, 4. 0, 6. 0, 8. 0 or 10. 0 bar Subsequent alteration of the setting is not permitted and is impossible without destroying the security cap Operating temperature -20 °C. . . +160 °C Connection size Internal thread on inlet 1/2", 3/4", Internal thread on outlet 1/2", 3/4", 1" Angled housing Adjustment spring Diaphragm Security cap with part label Brass housing Spring steel adjustment spring High grade synthetic material security cap Hot water resistant elastomer diaphragm Materials · · · · Valve size is defined by the size of the inlet connection www. honeywell. de/haustechnik 1 SM180 Diaphragm safety valve Method of Operation Do Diaphragm safety valves of this type are directacting safety valves in which the disc is pushed up by the pressure from the system against a spring which is holding the valve closed. If the opening force exceeds the force exerted by the spring, then the valve disc is lifted off the valve seat and the valve discharges the medium. In accordance with the requirements of the standard, the full discharge capacity of the valve will be achieved when the system pressure climbs to no more than 10% above the set pressure of the valve. Full shutoff must be achieved if the system pressure falls to below 80% of the nominal set pressure of the valve. For valves rated up to 3. 0 bar, the closing pressure can be taken as 0. 6 bar minimum. Options Set pressure SM180- 1/2ZA2. 5 2. 5 bar SM180- 1/2ZA3. 0 3. 0 bar SM180- 1/2ZA4. 0 4. 0 bar SM180- 1/2ZA6. 0 6. 0 bar SM180- 1/2ZA8. 0 8. 0 bar SM180- 1/2ZA10. 0 10. 0 bar SM180- 1/2A2. 5 2. 5 bar SM180- 1/2A3. 0 3. 0 bar SM180- 1/2A4. 0 4. 0 bar SM180- 1/2A6. 0 6. 0 bar SM180- 1/2A8. 0 8. 0 bar SM180- 1/2A10. 0 10. 0 bar SM180- 3/4ZA2. 5 2. 5 bar SM180- 3/4ZA3. 0 3. 0 bar SM180- 3/4ZA4. 0 4. 0 bar SM180- 3/4ZA6. 0 6. 0 bar SM180- 3/4ZA8. 0 8. 0 bar SM180- 3/4ZA10. 0 10. 0 bar SM180- 3/4A2. 5 2. 5 bar SM180- 3/4A3. 0 3. 0 bar SM180- 3/4A4. 0 4. 0 bar SM180- 3/4A6. 0 6. 0 bar SM180- 3/4A8. 0 8. 0 bar SM180- 3/4A10. 0 10. 0 bar OS. -No. Connection size Connection size Inlet Outlet Rp1/2" IG Rp1/2" IG 1/ " IG Rp 2 Rp1/2" IG 1/ " IG Rp1/2" IG Rp 2 1/ " IG Rp1/2" IG Rp 2 Rp1/2" IG Rp1/2" IG 1/ " IG Rp1/2" IG Rp 2 1/ " IG Rp3/4" IG Rp 2 1/ " IG Rp 2 Rp3/4" IG Rp3/4" IG Rp1/2" IG 1/ " IG Rp3/4" IG Rp 2 1/ " IG Rp 2 Rp3/4" IG 1/ " IG Rp3/4" IG Rp 2 Rp3/4" IG Rp3/4" IG 3/ " IG Rp 4 Rp3/4" IG 3/ " IG Rp3/4" IG Rp 4 3/ " IG Rp3/4" IG Rp 4 Rp3/4" IG Rp3/4" IG 3/ " IG Rp 4 Rp3/4" IG 3/ " IG Rp1" IG Rp 4 Rp1" IG Rp3/4" IG Rp3/4" IG Rp1" IG 3/ " IG Rp1" IG Rp 4 Rp1" IG Rp3/4" IG Rp1" IG Rp3/4" IG EN0H-1368GE23 R0609 · Änderungen vorbehalten H REintritt T RAustritt 1/ 1/ Connection size Inlet Connection size Outlet Dimensions Weight Maximum permissible heat input (kW) TÜV Approval Nos. . . * valid Approval No. R R (mm) H Do T g IG 2" IG 2" 3/ 3/ 4" IG 4" IG 1/ 3/ 2" IG 4" IG 3/ 4" IG 1" IG 60 33 32 135 50 - 62 33 46 145 100 - 62 60 36 33 46 46 140 150 50 100 TÜV · SV · . . * - 2017 · 13 · SOL · p Only the products with an outlet diameter larger than the inlet diameter are TÜV-certified. 2 www. honeywell. de/haustechnik SM180 Diaphragm safety valve Installation Example Installation Guidelines · · Mount the safety valve at the highest point of the heat generator or in its immediate vicinity on the flow line The installation must be carried out so that: o no shut-off fittings, restrictions or strainers are located between safety valve and heat generator o good access is provided for service and maintenance o that the safety valve is positioned above the heat generator o that between the safety valve and heat exchanger a max. 1 m long straight connection line with the size of the inlet diameter is installed The safety valve must be mounted so that in its installed condition no external forces act on it The discharge line must be performed to the size of the safety valve outlet diameter and may not have more than 2 elbows and or be longer than 2m The discharge line must be installed with an incline Typical Applications Membrane safety valves, according to their specification, are installed in the return connection of solar systems. [. . . ] A replacement is necessary if this action is not successful. Maintenance Specialist www. honeywell. de/haustechnik 3 SM180 Diaphragm safety valve Automation and Control Solutions Honeywell GmbH Hardhofweg D-74821 Mosbach Phone: (49) 6261 810 Fax: (49) 6261 81309 http://europe. hbc. honeywell. com www. honeywell. com Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell Technologies Sàrl, Rolle, Z. A. La Pièce 16, Switzerland by its Authorised Representative Honeywell GmbH EN0H-1368GE23 R0609 Subject to change without notice © 2009 Honeywell GmbH [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL SM180

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL SM180 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag