User manual HONEYWELL TBE DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HONEYWELL TBE. We hope that this HONEYWELL TBE user guide will be useful to you.

Lastmanuals help download the user guide HONEYWELL TBE.


Mode d'emploi HONEYWELL TBE
Download
Manual abstract: user guide HONEYWELL TBEDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] < Series TBE THERMOSTATIC EXPANSION VALVES FIXED ORIFICE, FLARE CONNECTIONS PRODUCT DATA Features · TBE: with internal pressure equalisation; for single injection in installations with one or more cooling circuits. · TBEX: with external pressure equalisation; for optimal evaporation effectiveness in all applications. [. . . ] Thermal systems with adsorber charge are completely insensitive to effects of temperature on the capillary tube and valve head. It reacts only according to the temperature of the bulb. Thus, Honeywell TBE(X) valves with combi adsorber charge work absolutely reliable, even in icy condition or while defrosting using hot gas. Adsorber charge with pressure limiting performance (MOP) Refrigerant R134a, R401A, R12 R22, R407C, R407A, R422D R404A, R507A, R402A, R407B, R502 Evaporation temperature range +5 °C to -30 °C -10 °C to -30 °C +5 °C to -45 °C -10 °C to -45 °C -27 °C to -45 °C -10 °C to -50 °C -20 °C to -50 °C -27 °C to -50 °C MOP PS (bar(a)) PF (bar(a)) MOP A +15 °C MOP A ±0 °C MOP A +15 °C MOP A ±0 °C MOP A -18 °C MOP A ±0 °C MOP A -10 °C MOP A -18 °C 34 29 36 29 29 36 34 34 37. 4 31. 9 39. 6 31. 9 31. 9 39. 6 37. 4 37. 4 Further refrigerants and MOP on request Capacities Type Orifice size 0. 5 0. 7 1. 0 TBE TBEX 1. 5 2. 0 2. 5 3. 0 3. 5 4. 5 Nominal capacity (kW)* R134a 0. 69 1. 0 1. 4 2. 2 2. 9 4. 0 6. 6 8. 7 11. 8 R22 0. 99 1. 4 2. 0 3. 2 4. 0 5. 8 9. 3 12. 2 17. 0 R407C 0. 95 1. 3 1. 9 3. 1 3. 9 5. 6 8. 9 11. 7 16. 4 R422D 0. 67 0. 92 1. 3 2. 2 2. 7 3. 9 6. 3 8. 3 11. 3 R404A 0. 68 0. 97 1. 4 2. 2 2. 8 4. 1 6. 5 8. 6 12. 0 R507A 0. 69 0. 98 1. 4 2. 3 2. 9 4. 1 6. 6 8. 7 12. 1 * Capacities are based on t0 = +4 °C, tc = +38 °C and 1 K subcooled liquid refrigerant entering the valve. For other operating conditions see capacity charts in Honeywell catalogue or consult the Honeywell software. EN0H-1906GE23 R0709 2 Honeywell GmbH · Subject to change without notice SERIES TBE Dimensions and Weights Connections Type Two-way construction Angle construction Inlet (A) 5/8" UNF 3/4" UNF Outlet (B) 3/4" UNF 7/8" UNF Pressure equalisation (C) 7/16" UNF 7/16" UNF D 47. 5 42. 5 E 40 Dimensions (mm) F 51. 5 46. 5 G 38 40 H 43 I 29 29 Weight (kg) approx. 0. 34 Connection = size of UNF thread TBE(X) 0. 5 - 4. 5 two-way TBE(X) 0. 5 - 4. 5 angle Type Code / Order Information TBE Series Pressure equalisation: X = external () = internal Orifice size Refrigerant Charge type, MOP, evaporation temperature range Flare connection UNF (inlet x outlet) D = two-way construction W = angle construction X 4. 5 R134a MOP A +15 °C 5/8" x 3/4" D Honeywell GmbH · Subject to change without notice 3 EN0H-1906GE23 R0709 SERIES TBE Installation · The valves may be installed in any position. · The external pressure equaliser line (TBEX) should be 6 mm or 1/4" in diameter and is to be connected downstream of the remote bulb. An overbow is recommended in order to prevent the ingress of oil into the equaliser line. · The bulb should preferably be positioned on the upper half of a horizontal suction line but never after a liquid trap. As a general rule, bulbs of expansion valves should be insulated to prevent them being affected by the ambient temperature. [. . . ] With TBEX angle construction there is no superheat setting in built-in condition possible, use factory setting. Automation and Control Solutions Honeywell GmbH Hardhofweg 74821 Mosbach/Germany Phone: +49 (0) 62 61 / 81-475 Fax: +49 (0) 62 61 / 81-461 E-Mail: cooling. mosbach@honeywell. com www. honeywell-cooling. com EN0H-1906GE23 R0709 4 Manufactured for and on behalf of the Environment and Combustion Controls Division of Honeywell Technologies Sàrl, 1180 Rolle, Z. La Pièce 16, Switzerland by its authorized representative Honeywell GmbH KAT-TBE-002 Honeywell GmbH · Subject to change without notice [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL TBE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL TBE will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag