[. . . ] Series TLESX THERMOSTATIC EXPANSION VALVES FIXED ORIFICE, ADJUSTABLE SUPERHEAT SETTING, SINGLE PORT PRODUCT DATA Features · Damped gas charge with MOP as standard · Optional available with liquid charge · Adjustable superheat setting · Warm thermal head provides best reliability · Solder connections · External pressure equalisation · Extreme durable due to stainless steel head and stainless steel diaphragm welded using protective gas · Single port construction, without high pressure compensation · Fixed orifice · Refrigerants: R22, R134a, R404A, R407C Further refrigerants on request. Specification Nominal capacity range Evaporating temperature range Maximum pressure PS Maximum test pressure PF Max. bulb temperature Static superheat Length of capillary tube Bulb diameter 22. 4 to 42. 4 kW R22 see table on page 2 see table on page 2 see table on page 2 100 °C gas charge: 140 °C liquid charge: 70 °C approx. [. . . ] 5 K higher than the required evaporating temperature of the system. With gas charged valves and MOP it is under all operating conditions necessary that the bulb is always colder than the capillary tube and the thermal head!With the Honeywell TLESX series the thermal head is heated advantageously by the liquid refrigerant. The warm thermal head is on the safe side at any time. Capacities Type Orifice size 4. 75 TLESX 5 6 Nominal capacity (kW)* R22 22. 4 29. 1 42. 4 R134a 15. 9 20. 0 27. 6 R404A 15. 8 20. 5 29. 8 R407C 21. 6 28. 0 40. 8 * Capacities are based on t0 = +4 °C, tc = +38 °C and 1 K subcooled liquid refrigerant entering the valve. For other operating conditions see capacity charts in Honeywell catalogue or consult the Honeywell software. Dimensions and Weights Connections Type Inlet (A) 12 mm ODF TLESX 1/2`` ODF 16 mm ODF 5/8`` ODF Outlet (B) 16 mm ODF 5/8`` ODF 22 mm ODF 7/8`` ODF Pressure equalizer (C) 6 mm ODF 1/4`` ODF 6 mm ODF 1/4`` ODF 71 56 74 54 61 54 55 D E Dimensions (mm) F G H I Weight (kg) approx. 0. 8 EN0H-1929GE23 R0709 2 Honeywell GmbH · Subject to change without notice SERIES TLESX TLESX Type Code / Order Information TLESX Series Orifice size Refrigerant MOP, evaporation temperature range Solder connection ODF (inlet x outlet) 5 R134a MOP +15 °C 12 mm x 16 mm Honeywell GmbH · Subject to change without notice 3 EN0H-1929GE23 R0709 SERIES TLESX Influence of Condensation Pressure to the Static Superheat Setting 5 4 3 Variation of static superheat setting [K] 2 1 0 -1 -2 -3 -4 -5 7 9 11 13 15 17 19 21 23 25 c o n d e n s a tio n p re s s u re [b a r] T L E S X 4 , 7 5 T LESX 5 + 6 Installation · The valves may be installed in any position. · The external pressure equaliser line should be 6 mm or 1/4" in diameter and is to be connected downstream of the remote bulb. An overbow is recommended in order to prevent the ingress of oil into the equaliser line. · The bulb should preferably be positioned on the upper half of a horizontal suction line but never after a liquid trap. As a general rule, bulbs of expansion valves should be insulated to prevent them being affected by the ambient temperature. · When soldering the valve, the valve body must not get warmer than 100 °C. · Do not bend or squeeze the bulb when thightening the bulb clamp! [. . . ] Increase of superheat setting results in a lower MOP value and vice versa. Automation and Control Solutions Honeywell GmbH Hardhofweg 74821 Mosbach/Germany Phone: +49 (0) 62 61 / 81-475 Fax: +49 (0) 62 61 / 81-461 E-Mail: cooling. mosbach@honeywell. com www. honeywell-cooling. com EN0H-1929GE23 R0709 4 Manufactured for and on behalf of the Environment and Combustion Controls Division of Honeywell Technologies Sàrl, 1180 Rolle, Z. La Pièce 16, Switzerland by its authorized representative Honeywell GmbH KAT-TLESX-002 Honeywell GmbH · Subject to change without notice [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL TLESX

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL TLESX will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag