User manual HONEYWELL V2461

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HONEYWELL V2461. We hope that this HONEYWELL V2461 user guide will be useful to you.

Lastmanuals help download the user guide HONEYWELL V2461.


Mode d'emploi HONEYWELL V2461
Download
Manual abstract: user guide HONEYWELL V2461

Detailed instructions for use are in the User's Guide.

[. . . ] V2461, V2471 Verafix-VK PRE-SETTABLE H-BLOCK FOR COMPACT RADIATORS PRODUCT DATA Application The verafix-VK is an adjustable lockshield valve for compact radiators with connection centres of 50 mm. It is used on twopipe and one-pipe systems with radiators which have integral valves to regulate and shut off individual radiators. [. . . ] 10, 0 bar (145 p. s. i. ) 1, 50 1, 23 1, 15 (angle) (straight) Materials · Matt nickel-plated hot-forged brass body · Brass valve insert · EPDM or NBR O-ring sealings · Brass union connections · Nickel-plated brass radiator connection nuts · Nickel-plated brass protection caps with NBR sealings Copyright © 2000 Honeywell AG · All rights reserved EN0H-033GE25 R1200 VERAFIX-VK Function Individual pre-setting of the Verafix-VK is made with a commercially available 4 mm hexagonal key by turning to the calculated value. The flow rate is adjusted by turning the spindle on the regulating valve. The relationship between the number of turns and the flow rate can be read off the flow diagram. Draining or filling can be carried out using the draining adapter (see accessories). The supply (or return) of the radiator can be shut off by turning the spindle on the Verafix-VK to the closed position with a hexagonal key. Draining, filling or shutting off the radiator with the Verafix-VK causes the pre-setting to be lost. Pre-settable Verafix-VK lockshield valves are supplied set fully open. The one-/two-pipe version is supplied with the bypass set fully closed Dimensions Fig. Dimensions Verafix-VK angle for 2-pipe systems Fig. Dimensions Verafix-VK angle for 1-pipe systems Fig. [. . . ] 0, 3 100 Flow kg/h 0, 05 2 3 0, 1 4 5 6 7 0, 2 8 9 1000 0, 5 0, 028 l/sec 0, 5 1, 0 2, 0 3, 0 4, 0 5, 0 6, 0 7 Radiator proportion kv-value 50% 1, 23 45% 1, 33 40% 1, 44 35% 1, 61 30% 1, 84 NOTE: Further radiator proportion values see page 8. EN0H-033GE25 R1200 6 Honeywell AG · All rights reserved 10 mbar Pa 1000 Pressure drop 2000 2 3 4 5 6 7 8 9 100 10000 2 3 4 5 VERAFIX-VK Flow diagram Verafix-VK, straight, in one-pipe systems Radiator proportion 50% 40% 30% 35% 45% 8 8, 7 0, 145 P. S. I. 0, 3 100 Flow kg/h 0, 05 2 3 0, 1 4 5 6 7 0, 2 8 9 1000 0, 5 0, 028 l/sec 0, 5 1, 0 2, 0 3, 0 4, 0 5, 0 6, 0 7 6 Radiator proportion kv-value 50% 1, 15 45% 1, 25 40% 1, 40 35% 1, 54 30% 1, 70 NOTE: Further radiator proportion values see page 8. Honeywell AG · All rights reserved 7 EN0H-033GE25 R1200 10 mbar Pa 1000 Pressure drop 2000 2 3 4 5 6 7 8 9 100 10000 2 3 4 5 VERAFIX-VK Radiator proportion and kv-values according to pre-setting for one-pipe systems Verafix-VK, angle Pre-setting 0, 5 1 1, 5 2 3 4 open Radiator proportion 60, 2% 40, 6% 37, 8% 36, 5% 32, 9% 28, 6% 21, 9% kv-value 1, 04 1, 42 1, 52 1, 56 1, 70 1, 91 2, 20 Verafix-VK, straight Pre-setting 0, 5 1 1, 5 2 3 4 open Radiator proportion 61, 0% 41, 6% 30, 9% 26, 8% 23, 7% 20, 7% 17, 9% kv-value 1, 00 1, 34 1, 66 1, 80 1, 86 1, 96 2, 15 Home and Building Control Honeywell AG Zu den Ruhrwiesen 3 D-59755 Arnsberg-Neheim EN0H-033GE25 R1200 Phone: (49) 2932 9880 Fax: (49) 2932 988239 mng@honeywell. com 8 http://europe. hbc. honeywell. com Subject to change · All rights reserved [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL V2461

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL V2461 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag