User manual HONEYWELL XFC2DXX DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HONEYWELL XFC2DXX. We hope that this HONEYWELL XFC2DXX user guide will be useful to you.

Lastmanuals help download the user guide HONEYWELL XFC2DXX.


Mode d'emploi HONEYWELL XFC2DXX
Download
Manual abstract: user guide HONEYWELL XFC2DXXDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] XFC1Axx, XFC1Dxx, XFC2Axx, XFC2Dxx, XFC3Axx, AND XFC3Dxx MODULES · LONMARKTM association-compliant, thus suitable for all open LONWORKS® networks · Flexible, software-configurable inputs/outputs · Flash memory for downloading applications (thus increasing flexibility and facilitating future upgrading) · 2-wire FTT-10A LONWORKS® bus interface · Easily-accessible service button and a service LED · Four fast digital inputs configurable for static input or totalizing (at up to 20 Hz) · Four relays to which (after software-configuration) e. g. floating actuators can be directly connected · Two or (model-dependent) four universal inputs, each with extra terminal for powering 24 Vac sensors, supporting (model-dependent) different sensor types, also configurable for voltage-variable or slow digital input · Two analog outputs, each with extra terminal for powering 24 Vac actuators, supporting (modeldependent) voltage-variable or current-variable output · Greater reliability, fewer cables (thus reducing fire burden), lower installation costs, easy start-up and servicing, digital communication · DIN rail (wiring cabinet / fuse box) mounting and wallmounting supported · Easy wiring check using the XILON Handheld MMI · Fixed or removable terminals (model-dependent) · 24 Vac, 110 Vac, or 230 Vac power supply (modeldependent) · Optional six three-position, software-configurable manual overrides and corresponding feedback · Optional terminal protection covers for wall mounting · Optional swivel label holders for wiring information Excel Smart I/O PRODUCT DATA FEATURES GENERAL Excel Smart I/O modules are LONMARK association-compliant devices, and can thus be used in all open LONWORKS environments. They feature a variety of software-configurable digital and analog inputs and outputs and are suitable for installation at strategic locations throughout your buildings. The modules convert physical input signals from sensors into network variables and the network variables into physical output signals for operating actuators. [. . . ] Transmitted immediately when its value has changed more counts than defined in "Send on Delta". Regularly transmitted as a heartbeat output. After power-up and reset, the value 0xFFFF=65535 will be sent to the network to indicate to the receiving device that previous count values have been lost due to a reset. Transmitted immediately when the digital input state has changed. Regularly transmitted as a heartbeat output as dictated by nciSndHrtBt. It is stored in the configuration parameter file accessible using standard LONMARK mechanisms. Used to define the properties associated with a digital input. Represents the current status of the analog output, including feedback related to manual override initiated from either nviAoManOvrd or the manual override switches. Typically used for monitoring purposes at supervisory stations or for diagnostic purposes. In the case of an override, the state is equal to -1. Used to drive the analog output to 0. . . 100%. Typically bound to a LONWORKS control device issuing an output level 0. . . 100%. A value of 110% is also possible (corresponding to a voltage range of 0. . . 11 V). Typically bound to a LONWORKS control device issuing an output level 0. . . 100%. A value of 110% is also possible (corresponding to a voltage range of 0. . . 11 V). Used to manually override the analog output to 0. . . 100%. Has priority over nviAoSwitch and nviAoValuePct. Typically used during start-up and commissioning, supported by the XILON Handheld MMI, and does not have to be bound. If the relay is at present manually overridden, this will be reflected in nvoAoActPosnFb, accordingly. The manual override remains in force until explicitly reset to normal operation via power-up and reset. This state is therefore stored in EEPROM. If there has been a manual override to the same output, this will have priority over nviAoManOvrd. [. . . ] This layout allows for maximum bus length, and its simple structure presents the least number of possible problems, particularly when adding on to an existing bus. For more information, please refer to http://www. echelon. com Analog Outputs Each module is equipped with two analog outputs providing either 0. . . 11 VDC, 0. . . ±1. 1 mA signals or 0. . 20 mA/4. . 20 mA signals (model-dependent). Each analog output features an extra power output terminal for supplying 24 Vac power to actuators. The analog outputs have a permissible load of > 10 kOhm, and a typical accuracy of ±0. 2 V. Other Module-Specific Features / Options Manual Overrides and Status LEDs The XFC1D06, the XFC2D05 and XFC2D06, as well as the XFC3D04, 3D05, and 3D06 are each equipped with six 3position (ON, OFF, AUTO) manual override sliding switches with which the individual digital/analog output signals can be overridden. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HONEYWELL XFC2DXX

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HONEYWELL XFC2DXX will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag