User manual HOTPOINT HLC 9.8 LT X/HA

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HOTPOINT HLC 9.8 LT X/HA. We hope that this HOTPOINT HLC 9.8 LT X/HA user guide will be useful to you.

Lastmanuals help download the user guide HOTPOINT HLC 9.8 LT X/HA.


Mode d'emploi HOTPOINT HLC 9.8 LT X/HA
Download
Manual abstract: user guide HOTPOINT HLC 9.8 LT X/HA

Detailed instructions for use are in the User's Guide.

[. . . ] € Extracted air must not be conveyed into a duct used for exhausting combustion fumes from gas or other fuel-fired equipment. • Observe all regulations in relation to air extraction. € NEVER cook food with an open flame under the hood; open flames will damage the filters and may cause fires. € Always supervise frying to make sure the heated oil does not catch fire. [. . . ] Electrical hook up The mains voltage must match that given on the ratings label inside the hood itself. If the hood has a power plug, connect the hood to an easily accessible regulatory power socket. If it does not (direct connection to the mains), or the socket is not easily accessible, install a two-pole regulatory switch to enable total disconnection from the mains in case of category III overvoltage, as required by the installation regulations. Always check that the mains cable is hooked up properly and check that it operates correctly before reconnecting the hood to the mains. Air exhaust (for ducted units) Connect the hood to a duct and wall exhaust hole of a diameter equal to that of the air outlet flange. Using a smaller diameter tube and exhaust hole reduces the extraction capacity of the hood and also increases its running noise. The manufacturer is not liable for any consequences of doing so. Use the shortest duct required to achieve the purpose. Use a duct with as few bends as possible !Avoid suddenly changing the diameter of the duct. The duct must have as smooth an inner surface as possible. T7 Antigrease and odour filter signal The antigrease (A) and odour (B) filters need cleaning/ replacing after a certain number of hours of use (the latter for filtering hoods only). The time for cleaning/replacement is signalled by the flashing of the coloured LED associated to the filter (white for antigrease filters, red for odour filter). The LED is turned off by pressing the T7 button after cleaning/replacing the filters. T8 lights ON/OFF It turns the work lights of the hood on and off. Hood configuration The configuration menu is accessed with the product off by pressing T5 and T6 for 6 seconds. T7 turns on at this point to indicate the type of installation through two colours of the LED: white for extractor installation (default), red for filtering installation. The installation type can be changed by pressing T7 cyclically with the consequent alternation of the LED colours. T1 T2 T3 T4 T5 T6 T1 motor ON/OFF When the button is pressed with the hood off, the first speed is set. When the button is pressed during operation, the hood switches OFF. T2 Speed – When the button is pressed the hood switches to the previous speed. T3 Speed + If the hood is set to speed 3, the intensive speed activates when this button is pressed The setting is limited by time; when it elapses the hood goes back to the speed set previously. [. . . ] do not use abrasive or corrosive products. Warning: Failure to observe the hood cleaning and filter cleaning/replacement instructions can result in fires. The manufacturer is not liable for any damage to the motor or fires caused by incorrect care or failure to follow the above instructions. Assembly: Secure the activated-carbon filter first in the back using the hood's metal tabs and then in the front by pressing the two levers. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HOTPOINT HLC 9.8 LT X/HA

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HOTPOINT HLC 9.8 LT X/HA will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag