User manual HUSKY MANIFOLD-SYSTEM-BOOKLET-060809

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HUSKY MANIFOLD-SYSTEM-BOOKLET-060809. We hope that this HUSKY MANIFOLD-SYSTEM-BOOKLET-060809 user guide will be useful to you.

Lastmanuals help download the user guide HUSKY MANIFOLD-SYSTEM-BOOKLET-060809.


Mode d'emploi HUSKY MANIFOLD-SYSTEM-BOOKLET-060809
Download
Manual abstract: user guide HUSKY MANIFOLD-SYSTEM-BOOKLET-060809

Detailed instructions for use are in the User's Guide.

[. . . ] Key features include: · · · · · · · · · 2, 4, and 8 Drop configurations Infinitely flexible nozzle spacing within upper and lower limits Three nozzle sizes (Ultra 500, Ultra 750, and Ultra 1000) Sixteen different gating styles including valve gate and thermal gate options Every application is reviewed and channel sizes are optimized for the application Suitable for a wide range of resins including engineering and filled resins Used in a broad variety of markets including housewares, closures, electronics, automotive, medical and more Lower cost than custom systems Faster delivery than custom systems This brochure provides information needed to do a preliminary layout of a mold using a Pronto manifold system. For information about Pronto complete hot runner systems, including plate drawings and standard feature locations please visit our web site www. hotrunners. com. Pronto manifold systems come complete with heated sprue bushing, nozzles, all necessary heaters and thermocouples, associated hardware, and wire clamps. Locating ring and electrical connectors are available upon request. [. . . ] However, these values cannot be combined otherwise interference will result (i. e. To verify that your pitch is acceptable, refer to the table below and solve for X & Y using the following calculation: U500VG / U750VG / U750HT X + 1. 47Y - 83. 7 >= 0 U500HT X + 1. 47Y - 65. 3 >= 0 If X and Y both satisfy the equation, then the pitch and sprue offset values can be incorporated into Pronto 2T. PRONTO 4 Drop H-Type Manifolds Nozzle 500/750 1000 500/750 1000 Minimum Pitch (X) 50mm (1. 969") 53mm (2. 087") Minimum Pitch (Y) 50mm (1. 969") 53mm (2. 087") Maximum Pitch (X) 211mm (8. 307") 362mm (14. 252") Maximum Pitch (Y) 331mm (13. 031") 200mm (7. 874") Number of T/C's 1 or 2 T/C Mounted Through Manifold/Backing Plate (If Req'd) Electrical Zones Y 6 or 7 X PRONTO 4 Drop N-Type Manifolds Nozzle Min Pitch (X1/X2/X3/X4) Max Pitch (X1X2/X3/X4) 1000 53mm (2. 087") Min Pitch (Y1/Y2) 53mm (2. 087") 362mm (14. 252") Max Pitch (Y1/Y2) 200mm (7. 874") Number of T/C's 1 or 2 T/C's Mounted Through Manifold/Backing Plate (If Req'd) Electrical Zones X1 X2 Y1 6 or 7 Y2 1000 X3 X4 Please confirm all dimensions and nozzle suitability by contacting Husky. 5 2003. 11 PRONTO PRONTO 4 Drop A-Type Manifolds Nozzle Minimum Pitch (X) Maximum Pitch (X) Number of T/C's 1 T/C Mounted Through Manifold Plate Electrical Zones 6 X 500/750 50mm (1. 969") 180mm (7. 087") X PRONTO 4 Drop L-Type Manifolds Nozzle 500/750 Minimum Pitch (X) Maximum Pitch (X) Number of T/C's Electrical Zones Y HT/TS 60mm (2. 363") HT/TS 316mm (12. 441") VG/VX 70mm (2. 756") VG/VX 304mm (11. 969") 1 T/C Mounted Minimum Pitch (Y) Maximum Pitch (Y) Through Manifold Plate HT/TS 105mm (4. 134") 500/750 361mm (14. 212") VG/VX 127mm (5. 000") 6 X NOTE: For HT/TS Y-dimension must be 45mm (1. 772") greater than X-dimension NOTE: For VG/VX Y-dimension must be 57mm (2. 244") greater than X-dimension PRONTO 8 Drop H-Type Manifolds Nozzle HT 500 Min X 73mm (0. 708") 73mm (0. 886") Max X Min Y1 211mm 61. 3mm (8. 307") (1. 752") 211mm 61. 3mm (8. 307") (1. 693") Max Y1 Min Y2 Max Y2 Number of Electrical T/C's Zones X Y2-62mm Y1+62mm 331mm 2 T/C Mounted (1. 000") (1. 000") (13. 031") Through Man Plate Y2-62mm Y1+62mm 331mm HT 750 2 T/C Mounted 11 or 13 (1. 771") (1. 771") (13. 031") Through Back 73mm 211mm 61. 3mm Y2-62mm Y1+62mm 331mm Plate (when VG 500/750 (0. 984") (8. 307") (2. 165") (1. 968") (1. 968") (13. 031") required) Y2 Y1 Please confirm all dimensions and nozzle suitability by contacting Husky. 2003. 11 6 1 Drop PRONTO 1 Drop I-Type Manifolds (Ultra 1000 Only) X + 28, 0 [1. 10] X + 29, 00 [1. 142] X + 15, 2 [0. 60] X + 45, 0 [1. 77] PRONTO 0, 000 [. 0000] 113, 0 [4. 45] 35, 0 [1. 38] 35, 0 [1. 38] RAD 35, 0 [1. 38] 40, 0 [1. 57] 28, 0 [1. 10] 0, 000 [. 0000] 15, 2 [0. 60] 28, 0 [1. 10] 29, 0 [1. 14] 40, 0 [1. 57] R 27, 0 [1. 06] (4) X RAD 27, 5 [1. 08] View From Injection Side Plate features are noted on plan view and correspond to features in section view below. For HT / TS For HT / TS 26. 8 [1. 06] 40. 0 [1. 57] 12. 5 [0. 49] 3. 0 MIN [. 12] 8. 000 +0. 015 [. 3150 +. 0006] *C 1/4 -20 M6 (2) *B 80. 8 [3. 18] BK-PLT *B 6. 8 [. 27] MF-PLT 6. 8 x 17. 0 DP. 42. 0 [1. 66] [ . 32 +. 0001 x . 59 DP. ] 60. 01 +0. 03 [2. 36 +. 0001] 30. 0 MAX 1. 5R [1. 18] [. 06] 44. 01 +0. 03 [1. 733 +. 001] R 1. 5 [. 06] MAX 22. 2 [. 88] T/C MF-PLT THRU HOLE FOR X> 87 mm 22. 2 [. 88] T/C MF-PLT Minimum Pitch (X) Maximum Pitch (X) HT/TS 55mm (2. 165") VG/VX 74mm (2. 913") Number of T/C's Electrical T/C : Thermocouple Zones BK - PLT : Manifold Backing Plate MF - PLT : Manifold Plate X : Pitch X Value 695mm (27. 362") 1 T/C Mounted Through Manifold Plate 3 Y : Pitch Y Value R, RAD : Radius C : Center Insulator Bore Depth* B : Nozzle Bore Depth* *Refer to calculator on www. hotrunners. com Please confirm all dimensions and nozzle suitability by contacting Husky. 7 2003. 11 92. 6 [3. 65] RAD 3. 0 [. 12] 75. 0 [2. 95] 79. 0 [3. 11] 70. 00 [2. 76] 60. 00 [2. 36] 68. 00 [2. 68] 60. 00 [2. 36] M16 [5/8-11 UNC] (3 Bolts per drop recommeded) For VG / VX PRONTO PRONTO 2 Drop A-Type Manifolds (Ultra 1000) X - 52, 2 [X - 2 . 06] IF X<100, 0 [3. 94] T/C IS SIDE MOUNTED 2 Drop X + 41, 00 [1. 614] X + 25, 0 [. 98] 0, 000 [. 0000] 35, 0 [1. 38] 32, 0 [1. 26] 32, 0 [1. 26] 35, 0 [1. 38] X 100, 0 [3. 94] RAD 5, 0 [. 20] (2) RAD 35, 0 [1. 38] 60, 0 [2. 36] 40, 0 [1. 58] 28, 0 [1. 10] RAD 27, 5 [1. 08] 0, 000 [0. 0000] 28, 0 [1. 10] 40, 0 [1. 58] View From Injection Side RAD 27, 0 (5) [1. 06] Plate features are noted on plan view and correspond to features in section view below. For HT / TS For HT / TS X + 45, 0 [1. 77] 26. 8 [1. 06] 40. 0 [1. 57] 12. 5 [0. 49] 3. 0 MIN [. 12] 8. 000 +0. 015 [. 3150 +. 0006] *C 1/4 -20 M6 (2) *B 80. 8 [3. 18] BK-PLT *B 6. 8 [. 27] MF-PLT 6. 8 x 17. 0 DP. Plate features are noted on plan view and correspond to features in section view below. For HT / TS For VG /VX M12 [1/2-13 UNC] (3 Bolts per drop recommeded) For HT / TS For VG /VX MAX MIN Sharp THRU HOLE FOR X > 87 mm T/C : Thermocouple BK - PLT : Manifold Backing Plate Minimum Pitch (X) Maximum Pitch (X) HT/TS 60mm (2. 363") VG/VX 70mm (2. 756") Number of T/C's Electrical Zones MF - PLT : Manifold Plate X : Pitch X Value Y : Pitch Y Value R, RAD : Radius 366mm (14. 409") 1 T/C Mounted Through Manifold Plate 4 C : Center Insulator Bore Depth* B : Nozzle Bore Depth* *Refer to calculator on www. hotrunners. com Please confirm all dimensions and nozzle suitability by contacting Husky. 2003. 11 10 For VG /VX 2 Drop PRONTO 2 Drop T-Type Manifold Type I (Ultra 1000) X + 41, 00 [1. 614] X + 21, 5 [. 85] X + 28, 0 [1. 10] 24, 0 [0. 95] 31. 45 [1. 238] 24, 0 [0. 95] 0, 000 [. 0000] 30, 0 [1. 18] 61, 0 [2. 40] X PRONTO 47, 0 [1. 85] 41, 0 [1. 61] 30, 0 [1. 18] 0, 000 [. 0000] 14, 0 [0. 55] RAD 27, 5 [1. 08] RAD 35, 0 [1. 38] R 10, 0 (2) [0. 39] Contact Husky for T/C Location 51, 0 [2. 01] Y Y + 39, 32 [1. 548] View From Injection Side Y + 130, 0 [5. 12] R 27, 0 (6) [1. 06] Contact Husky to verfiy T/C thru hole location. Plate features are noted on plan view and correspond to features in section view below. For HT / TS For HT / TS M16 [5/8-11 UNC] (3 Bolts per drop recommeded) 68. 00 [2. 68] For VG / VX 60. 00 [2. 36] 79. 0 [3. 11] 40. 0 [1. 57] 12. 5 [0. 49] 3. 0 MIN [. 12] 8. 000 +0. 015 [. 3150 +. 0006] *C 1/4 -20 M6 (2) *B 80. 8 [3. 18] BK-PLT *B 6. 8 [. 27] MF-PLT 6. 8 x 17. 0 DP. 42. 0 [1. 66] [ . 32 +. 0001 x . 59 DP. ] 60. 01 +0. 03 [2. 36 +. 0001] 30. 0 MAX 1. 5R [1. 18] [. 06] 44. 01 +0. 03 [1. 733 +. 001] R 1. 5 [. 06] MAX 22. 2 [. 88] T/C MF-PLT THRU HOLE FOR X> 87 mm 22. 2 [. 88] T/C MF-PLT T/C : Thermocouple Minimum Pitch (X) 53mm (2. 087") Minimum Pitch (Y) 53mm (2. 087") Maximum Pitch (X) 362mm (14. 252") Maximum Pitch (Y) 200mm (7. 874") Number of T/C's 1 or 2 T/C Mounted Through Manifold Plate Electrical Zones 4 or 5 BK - PLT : Manifold Backing Plate MF - PLT : Manifold Plate X : Pitch X Value Y : Pitch Y Value R, RAD : Radius C : Center Insulator Bore Depth* B : Nozzle Bore Depth* *Refer to calculator on www. hotrunners. com Please confirm all dimensions and nozzle suitability by contacting Husky. 11 2003. 11 92. 6 [3. 65] RAD 3. 0 [. 12] 75. 0 [2. 95] 70. 00 [2. 76] 60. 00 [2. 36] 26. 8 [1. 06] PRONTO PRONTO 2 Drop T-Type Manifold Type I (Ultra 750) X + 15, 0 [0. 591] - 24, 00 [- 0. 945] 0, 000 [0. 000] 22, 65 [0. 892] 24, 0 [0. 94] 26, 000 [1. 0236] 61, 1 [2. 41] (2) 66, 0 [2. 60] - 56, 0 [- 2. 20] -100, 0 [3. 94] 2 Drop X RAD 22, 0 [0. 87] (2) Y + 55, 0 [+ 2. 165] Y + 38, 0 [+ 1. 496] Y + 33, 72 [+ 1. 328] Y + 25, 5 [+ 1. 004] Y + 23, 0 [+ 0. 906] Y + 6, 0 [+ 0. 236] Y Y - 6, 0 [- 0. 236] TOP Y - 38, 0 [- 1. 496] Y - 48, 0 [- 1. 890] RAD 5, 0 [0. 20] (2) RAD 15, 0 [0. 59] Recommeded drop bolt circle Min > 10, 0 [0. 394] R 55, 0 [2. 17] 0, 000 [0. 0000] - 1, 0 [- 0. 04] - 31, 65 [- 1. 246] - 33, 0 [- 1. 30] View From Injection Side RAD 27, 0 [1. 06] (8) OPERATOR Contact Husky to verify T/C thru hole location. Plate features are noted on plan view and correspond to features in section view below. For HT / TS For VG /VX For HT / TS For HT / TS For VG /VX M16 [5/8-11 UNC] (3 Bolts per drop recommeded) MAX MIN MAX T THRU HOLE FOR X>87 mm T/C : Thermocouple Minimum Pitch (X1/X2) HT 500 12. 7mm (0. 500") HT/TS 750 22. 5mm (0. 886") VG 500/750 25. 0mm (0. 984") Minimum Pitch (Y) HT 500 25. 4mm (1. 000") HT/TS 750 25. 4mm (1. 000") VG 500/750 25. 4mm (1. 000") 2003. 11 Maximum Pitch (X1/X2) Number Electrical BK - PLT : Manifold Backing Plate of T/C's Zones MF - PLT : Manifold Plate X : Pitch X Value Y : Pitch Y Value R, RAD : Radius HT 500 350. 0mm (13. 780") HT/TS 750 350. 0mm (13. 780") 1 or 2 T/C VG 500/750 350. 0mm (13. 780") Mounted Maximum Pitch (Y) Through Manifold HT 500 200. 0mm (7. 874") Plate HT/TS 750 200. 0mm (7. 874") VG 500/750 200. 0mm (7. 874") 4 or 5 C : Center Insulator Bore Depth* B : Nozzle Bore Depth* *Refer to calculator on www. hotrunners. com Please confirm all dimensions and nozzle suitability by contacting Husky. 12 For VG /VX 2 Drop PRONTO 2 Drop T-Type Manifold Type I (Ultra 500) X + 15, 0 [0. 591] - 24, 00 [- 0. 945] 0, 000 [0. 000] 22, 65 [0. 892] 24, 0 [0. 94] 26, 000 [1. 0236] 61, 1 [2. 41] (2) 66, 0 [2. 60] - 56, 0 [- 2. 20] -100, 0 [3. 94] PRONTO X RAD 22, 0 [0. 87] (2) Y + 55, 0 [+ 2. 165] Y + 38, 0 [+ 1. 496] Y + 33, 72 [+ 1. 328] Y + 18, 0 [+ 0. 17] (2) Y + 23, 0 [+ 0. 906] Y + 6, 0 [+ 0. 236] Y Y - 6, 0 [- 0. 236] Y - 38, 0 [- 1. 496] Y - 48, 0 [- 1. 890] RAD 5, 0 [0. 20] (2) RAD 15, 0 [0. 59] TOP R 55, 0 [2. 17] Recommeded drop bolt circle Min > 10, 0 [0. 394] 0, 000 [0. 0000] - 1, 0 [- 0. 04] - 31, 65 [- 1. 246] - 33, 0 [- 1. 30] RAD 27, 0 [1. 06] (8) View From Injection Side OPERATOR Contact Husky to verfiy T/C thru hole location. Plate features are noted on plan view and correspond to features in section view below. For HT / TS For VG /VX For HT / TS For VG /VX M12 [1/2-13 UNC] (3 Bolts per drop recommeded) MAX MIN Sharp THRU HOLE FOR X > 87 mm T/C : Thermocouple Minimum Pitch (X1/X2) HT 500 12. 7mm (0. 500") HT/TS 750 22. 5mm (0. 886") VG 500/750 25. 0mm (0. 984") Minimum Pitch (Y) HT 500 25. 4mm (1. 000") HT/TS 750 25. 4mm (1. 000") VG 500/750 25. 4mm (1. 000") Maximum Pitch (X1/X2) Number of Electrical T/C's Zones BK - PLT : Manifold Backing Plate MF - PLT : Manifold Plate X : Pitch X Value Y : Pitch Y Value R, RAD : Radius HT 500 350. 0mm (13. 780") HT/TS 750 350. 0mm (13. 780") 1 or 2 T/C VG 500/750 350. 0mm (13. 780") Mounted Maximum Pitch (Y) Through Manifold HT 500 200. 0mm (7. 874") Plate HT/TS 750 200. 0mm (7. 874") VG 500/750 200. 0mm (7. 874") 4 or 5 C : Center Insulator Bore Depth* B : Nozzle Bore Depth* *Refer to calculator on www. hotrunners. com Please confirm all dimensions and nozzle suitability by contacting Husky. For VG /VX 13 2003. 11 PRONTO PRONTO 2 Drop T-Type Manifold Type II (Ultra 750) RAD 27, 0 [1. 06] (8) 2 Drop + 33, 0 [+ 1. 30] + 31, 65 [+ 1. 246] + 1, 0 [+ 0. 04] 0, 000 [0. 0000] Min > 10, 0 [0. 394] R 55, 0 [2. 17] TOP Recommeded drop bolt circle RAD 5, 0 [0. 20] (2) Y + 48, 0 [+ 1. 890] Y + 38, 0 [+ 1. 496] RAD 15, 0 [0. 59] Y + 6, 0 [+ 0. 236] Y Y - 6, 0 [- 0. 236] Y - 23, 0 [- 0. 906] Y - 25, 5 [- 1. 004] Y - 33, 72 [- 1. 328] Y - 38, 0 [- 1. 496] Y - 55, 0 [- 2. 165] RAD 22, 0 [0. 87] (2) X + 15, 0 [0. 591] -100, 0 [- 3. 94] View From Injection Side OPERATOR Contact Husky to verfiy T/C thru hole location. Plate features are noted on plan view and correspond to features in section view below. For HT / TS For VG /VX For HT / TS - 24, 00 [- 0. 945] 0, 000 [0. 000] 22, 65 [0. 892] 24, 0 [0. 94] 26, 000 [1. 0236] 61, 1 [2. 41] (2) 66, 0 [2. 60] - 56, 0 [- 2. 20] X For HT / TS For VG /VX M16 [5/8-11 UNC] (3 Bolts per drop recommeded) MAX MIN MAX T THRU HOLE FOR X>87 mm Minimum Pitch (X1/X2) Maximum Pitch (X1/X2) Number of T/C's Electrical Zones T/C : Thermocouple BK - PLT : Manifold Backing Plate MF - PLT : Manifold Plate X : Pitch X Value Y : Pitch Y Value R, RAD : Radius HT 500 350. 0mm (13. 780") HT 500 12. 7mm (0. 500") HT/TS 750 350. 0mm (13. 780") HT/TS 750 22. 5mm (0. 886") 1 or 2 T/C VG 500/750 350. 0mm VG 500/750 25. 0mm (0. 984") Mounted (13. 780") Through Minimum Pitch (Y) Maximum Pitch (Y) Manifold HT 500 25. 4mm (1. 000") HT 500 200. 0mm (7. 874") Plate HT/TS 750 25. 4mm (1. 000") HT/TS 750 200. 0mm (7. 874") VG 500/750 25. 4mm (1. 000") VG 500/750 200. 0mm (7. 874") 2003. 11 4 or 5 C : Center Insulator Bore Depth* B : Nozzle Bore Depth* *Refer to calculator on www. hotrunners. com Please confirm all dimensions and nozzle suitability by contacting Husky. 14 For VG /VX 2 Drop PRONTO 2 Drop T-Type Manifold Type II (Ultra 500) RAD 27, 0 [1. 06] (8) PRONTO + 33, 0 [+ 1. 30] + 31, 65 [+ 1. 246] + 1, 0 [+ 0. 04] 0, 000 [0. 0000] Min > 10, 0 [0. 394] R 55, 0 [2. 17] Recommeded drop bolt circle TOP RAD 5, 0 [0. 20] (2) Y + 48, 0 [+ 1. 890] Y + 38, 0 [+ 1. 496] Y + 18, 0 [+ 0. 17] Y + 6, 0 [+ 0. 236] Y Y - 6, 0 [- 0. 236] Y - 23, 0 [- 0. 906] Y - 33, 72 [- 1. 328] Y - 38, 0 [- 1. 496] Y - 55, 0 [- 2. 165] RAD 15, 0 [0. 59] RAD 22, 0 [0. 87] (2) X + 15, 0 [0. 591] -100, 0 [- 3. 94] View From Injection Side OPERATOR Plate features are noted on plan view and correspond to features in section view below. For HT / TS For VG /VX - 24, 00 [- 0. 945] 0, 000 [0. 000] 22, 65 [0. 892] 24, 0 [0. 94] 26, 000 [1. 0236] 61, 1 [2. 41] (2) 66, 0 [2. 60] - 56, 0 [- 2. 20] X M12 [1/2-13 UNC] (3 Bolts per drop recommeded) MAX MIN Sharp THRU HOLE FOR X > 87 mm Minimum Pitch (X1/X2) Maximum Pitch (X1/X2) Number of T/C's Electrical Zones T/C : Thermocouple BK - PLT : Manifold Backing Plate MF - PLT : Manifold Plate X : Pitch X Value Y : Pitch Y Value R, RAD : Radius C : Center Insulator Bore Depth* B : Nozzle Bore Depth* *Refer to calculator on www. hotrunners. com HT 500 12. 7mm (0. 500") HT 500 350. 0mm (13. 780") HT/TS 750 22. 5mm (0. 886") HT/TS 750 350. 0mm (13. 780") 1 or 2 T/C VG 500/750 25. 0mm (0. 984") VG 500/750 350. 0mm (13. 780") Mounted Minimum Pitch (Y) Maximum Pitch (Y) Through Manifold HT 500 25. 4mm (1. 000") HT 500 200. 0mm (7. 874") Plate HT/TS 750 25. 4mm (1. 000") HT/TS 750 200. 0mm (7. 874") VG 500/750 25. 4mm (1. 000") VG 500/750 200. 0mm (7. 874") 4 or 5 Please confirm all dimensions and nozzle suitability by contacting Husky. For VG /VX 15 2003. 11 PRONTO PRONTO 2 Drop T-Type Manifold Type III (Ultra 750) TOP - 24, 00 [- 0. 945] (2) 22, 65 [0. 892] 26, 000 [1. 0236] 32, 0 [1. 26] (2) X + 15, 0 [0. 59] 53, 2 [2. 10] (2) 61, 0 [2. 40] (2) 0, 000 [0. 000] 2 Drop Y + 93, 0 [3. 66] X RAD 5, 000 [0. 1969] (4) Y + 59, 2 [2. 33] Y + 38, 0 [1. 50] (2) Y + 33, 72 [1. 328] Y + 25, 50 [1. 004] OPERATOR Y + 6, 0 [0. 24] Y Y - 6, 0 [0. 24] Y - 43, 0 [1. 69] R 55, 0 [2. 17] RAD 10, 000 [0. 3937] (2) Recommeded drop bolt circle 0, 000 [0. 000] View From Injection Side -31. 65 [-1. 246] - 33, 0 [-1. 30] (2) RAD 27, 0 [1. 0630] (7) Plate features are noted on plan view and correspond to features in section view below. For HT / TS For VG /VX For HT / TS For HT / TS For VG /VX M16 [5/8-11 UNC] (3 Bolts per drop recommeded) MAX MIN MAX T THRU HOLE FOR X>87 mm Minimum Pitch (X1/X2) HT 500 12. 7mm (0. 500") HT/TS 750 22. 5mm (0. 886") VG 500/750 25. 0mm (0. 984") Minimum Pitch (Y) HT 500 25. 4mm (1. 000") HT/TS 750 25. 4mm (1. 000") VG 500/750 25. 4mm (1. 000") Maximum Pitch (X1/X2) HT 500 350. 0mm (13. 780") HT/TS 750 350. 0mm (13. 780") VG 500/750 350. 0mm (13. 780") Maximum Pitch (Y) HT 500 200. 0mm (7. 874") HT/TS 750 200. 0mm (7. 874") VG 500/750 200. 0mm (7. 874") Number of Electrical T/C's Zones 1 or 2 T/C Mounted Through Manifold Plate T/C : Thermocouple BK - PLT : Manifold Backing Plate MF - PLT : Manifold Plate X : Pitch X Value Y : Pitch Y Value R, RAD : Radius 4 or 5 C : Center Insulator Bore Depth* B : Nozzle Bore Depth* *Refer to calculator on www. hotrun- Please confirm all dimensions and nozzle suitability by contacting Husky. 2003. 11 16 For VG /VX 2 Drop PRONTO 2 Drop T-Type Manifold Type III (Ultra 500) TOP - 24, 00 [- 0. 945] (2) 22, 65 [0. 892] 26, 000 [1. 0236] 32, 0 [1. 26] (2) X + 15, 0 [0. 59] 53, 2 [2. 10] (2) 61, 0 [2. 40] (2) 0, 000 [0. 000] PRONTO Y + 93, 0 [3. 66] X RAD 5, 000 [0. 1969] (4) Y + 59, 2 [2. 33] Y + 38, 0 [1. 50] (2) Y + 33, 72 [1. 328] OPERATOR Y + 18, 0 [+ 0. 17] Y + 6, 0 [0. 24] Y Y - 6, 0 [0. 24] Y - 43, 0 [1. 69] R 55, 0 [2. 17] RAD 10, 000 [0. 3937] (2) Recommeded drop bolt circle 0, 000 [0. 000] View From Injection Side -31. 65 [-1. 246] - 33, 0 [-1. 30] (2) RAD 27, 0 [1. 0630] (7) Plate features are noted on plan view and correspond to features in section view below. For HT / TS For VG /VX M12 [1/2-13 UNC] (3 Bolts per drop recommeded) MAX MIN Sharp THRU HOLE FOR X > 87 mm Minimum Pitch (X1/X2) Maximum Pitch (X1/X2) Number of Electrical T/C's Zones T/C : Thermocouple BK - PLT : Manifold Backing Plate MF - PLT : Manifold Plate X : Pitch X Value Y : Pitch Y Value R, RAD : Radius HT 500 12. 7mm (0. 500") HT 500 350. 0mm (13. 780") HT/TS 750 22. 5mm (0. 886") HT/TS 750 350. 0mm (13. 780") 1 or 2 T/C VG 500/750 25. 0mm (0. 984") VG 500/750 350. 0mm (13. 780") Mounted Minimum Pitch (Y) Maximum Pitch (Y) Through Manifold HT 500 25. 4mm (1. 000") HT 500 200. 0mm (7. 874") Plate HT/TS 750 25. 4mm (1. 000") HT/TS 750 200. 0mm (7. 874") VG 500/750 25. 4mm (1. 000") VG 500/750 200. 0mm (7. 874") 4 or 5 C : Center Insulator Bore Depth* B : Nozzle Bore Depth* *Refer to calculator on www. hotrunners. com Please confirm all dimensions and nozzle suitability by contacting Husky. For VG /VX 17 2003. 11 PRONTO PRONTO 4 Drop H-Type Manifolds (Ultra 1000) X + 41, 00 [1. 614] X + 28, 0 [1. 10] X + 21, 5 [. 85] X + 39, 7 [1. 56] X + 21, 0 [0. 83] X + 21, 0 [1. 06] 0, 000 [. 0000] 4 Drop X 56, 7 [2. 23] RAD 27, 0 (6) [1. 06] Y1 + 100, 0 [3. 94] RAD 12, 7 (6) [1. 06] RAD 35, 0 Y1 + 61, 7 [2. 43] Contact Husky for T/C Location Y1 + 22, 0 [0. 87] Y1 Y1 - 13, 0 [0. 51] Y1 - 17, 7 [0. 70] Y1 - 52, 7 [2. 07] [1. 38] RAD 27, 5 [1. 08] 0, 000 [. 0000] Y2 - 52, 7 [2. 07] Y2 - 17, 7 [0. 70] Y2 - 13, 0 [0. 51] Y2 View From Injection Side Y2 + 22, 0 [0. 87] Plate features are noted on plan view and correspond to features in section view below. For HT / TS For HT / TS 26. 8 [1. 06] 40. 0 [1. 57] 12. 5 [0. 49] 3. 0 MIN [. 12] 8. 000 +0. 015 [. 3150 +. 0006] *C 1/4 -20 M6 (2) *B 80. 8 [3. 18] BK-PLT *B 6. 8 [. 27] MF-PLT 6. 8 x 17. 0 DP. 42. 0 [1. 66] [ . 32 +. 0001 x . 59 DP. ] 60. 01 +0. 03 [2. 36 +. 0001] 30. 0 MAX 1. 5R [1. 18] [. 06] 44. 01 +0. 03 [1. 733 +. 001] R 1. 5 [. 06] MAX 22. 2 [. 88] T/C MF-PLT THRU HOLE FOR X> 87 mm 22. 2 [. 88] T/C MF-PLT T/C : Thermocouple BK - PLT : Manifold Backing Plate Minimum Pitch (X) Maximum Pitch (X) Number of T/C's Electrical Zones 6 or 7 MF - PLT : Manifold Plate X : Pitch X Value Y : Pitch Y Value R, RAD : Radius C : Center Insulator Bore Depth* B : Nozzle Bore Depth* *Refer to calculator on www. hotrunners. com 53mm (2. 087") 362mm (14. 252") 1 T/C Mounted thru MF PLT Minimum Pitch (Y) Maximum Pitch (Y) 1 T/C Mounted Thru BK PLT (when required) 53mm (2. 087") 200mm (7. 874") Please confirm all dimensions and nozzle suitability by contacting Husky. 2003. 11 18 92. 6 [3. 65] RAD 3. 0 [. 12] 75. 0 [2. 95] 79. 0 [3. 11] 70. 00 [2. 76] 60. 00 [2. 36] 68. 00 [2. 68] 60. 00 [2. 36] M16 [5/8-11 UNC] (4 Bolts per drop recommended) For VG / VX For VG / VX 4 Drop PRONTO 4 Drop H-Type Manifolds (Ultra 750) PRONTO Manifold Heater #1A (Clamp) #1B (Injection) Recommeded drop bolt circle View From Injection Side Plate features are noted on plan view and correspond to features in section view below. For HT / TS For VG /VX For HT / TS For HT / TS For VG /VX M16 [5/8-11 UNC] (3 Bolts per drop recommeded) MAX MIN MAX T THRU HOLE FOR X>87 mm T/C : Thermocouple BK - PLT : Manifold Backing Plate MF - PLT : Manifold Plate X : Pitch X Value Y : Pitch Y Value R, RAD : Radius C : Center Insulator Bore Depth* Minimum Pitch (X) HT/TS 50mm (1. 969") VG/VX 50mm (1. 969") Minimum Pitch (Y) HT/TS 50mm (1. 969") VG/VX 50mm (1. 969") Maximum Pitch (X) Number of T/C's Electrical Zones HT/TS 211mm (8. 307") 1 T/C Mounted VG/VX 211mm (8. 307") Through MF PLT Maximum Pitch (Y) 1 T/C Mounted Through BK PLT 331mm (13. 031") (when required) 6 or 7 B : Nozzle Bore Depth* *Refer to calculator on www. hotrunners. com Please confirm all dimensions and nozzle suitability by contacting Husky. 19 For VG /VX 2003. 11 PRONTO PRONTO 4 Drop H-Type Manifolds (Ultra 500) 4 Drop Manifold Heater #1A (Clamp) #1B (Injection) Recommeded drop bolt circle View From Injection Side Plate features are noted on plan view and correspond to features in section view below. For HT / TS For VG /VX M12 [1/2-13 UNC] (3 Bolts per drop recommeded) MAX MIN Sharp THRU HOLE FOR X > 87 mm T/C : Thermocouple BK - PLT : Manifold Backing Plate MF - PLT : Manifold Plate X : Pitch X Value Y : Pitch Y Value R, RAD : Radius C : Center Insulator Bore Depth* Minimum Pitch (X) HT/TS 50mm (1. 969") VG/VX 50mm (1. 969") Minimum Pitch (Y) HT/TS 50mm (1. 969") VG/VX 50mm (1. 969") 2003. 11 Maximum Pitch (X) Number of T/C's Electrical Zones HT/TS 211mm (8. 307") 1 T/C Mounted VG/VX 211mm (8. 307") Through MF PLT Maximum Pitch (Y) 1 T/C Mounted Through BK PLT 331mm (13. 031") (when required) 6 or 7 B : Nozzle Bore Depth* *Refer to calculator on www. hotrunners. com Please confirm all dimensions and nozzle suitability by contacting Husky. 20 For VG /VX 4 Drop PRONTO 4 Drop A-Type Manifolds (Ultra 750) PRONTO T/C Manifold Heater #1A (Clamp) #1B (Injection) View From Injection Side Recommeded drop bolt circle For HT / TS For VG /VX For HT / TS M16 [5/8-11 UNC] (3 Bolts per drop recommeded) For HT / TS For VG /VX MAX MIN MAX T THRU HOLE FOR X>87 mm T/C : Thermocouple BK - PLT : Manifold Backing Plate MF - PLT : Manifold Plate X : Pitch X Value Y : Pitch Y Value R, RAD : Radius C : Center Insulator Bore Depth* B : Nozzle Bore Depth* *Refer to calculator on www. hotrunners. com Please confirm all dimensions and nozzle suitability by contacting Husky. Minimum Pitch (X) Maximum Pitch (X) 50mm (1. 969") 180mm (7. 087") Number of T/C's 1 T/C Mounted Through Manifold Plate Electrical Zones 6 For VG /VX 21 2003. 11 PRONTO PRONTO 4 Drop A-Type Manifolds (Ultra 500) 4 Drop T/C Manifold Heater #1A (Clamp) #1B (Injection) View From Injection Side Recommeded drop bolt circle For HT / TS For VG /VX M12 [1/2-13 UNC] (3 Bolts per drop recommeded) MAX MIN Sharp THRU HOLE FOR X > 87 mm T/C : Thermocouple Minimum Pitch (X) Maximum Pitch (X) 50mm (1. 969") 180mm (7. 087") Number of T/C's 1 T/C Mounted Through Manifold Plate Electrical Zones 6 BK - PLT : Manifold Backing Plate MF - PLT : Manifold Plate X : Pitch X Value Y : Pitch Y Value R, RAD : Radius C : Center Insulator Bore Depth* B : Nozzle Bore Depth* *Refer to calculator on www. hotrunners. com Please confirm all dimensions and nozzle suitability by contacting Husky. 2003. 11 22 For VG /VX 4 Drop PRONTO 4 Drop N-Type Manifolds (Ultra 1000) X1 + 41, 00 [1. 614] X1 + 28, 0 [1. 10] X1 + 21, 5 [. 85] - 56, 7 [2. 23] - 39, 7 [1. 56] - 21, 0 [0. 83] 0, 000 [. 0000] PRONTO X1 21, 0 [1. 06] RAD 27, 0 (6) [1. 06] Y1 + 100, 0 [3. 94] RAD 12, 7 (6) [1. 06] Y1 + 61, 7 [2. 43] RAD 35, 0 [1. 38] Contact Husky for T/C location Y1 + 22, 0 [0. 87] Y1 Y1 - 13, 0 [0. 51] Y1 - 17, 7 [0. 70] Y1 - 52, 7 [2. 07] X2 RAD 27, 5 [1. 08] 0, 000 [. 0000] Y2 - 52, 7 [2. 07] Y2 - 17, 7 [0. 70] Y2 - 13, 0 [0. 51] Y2 View From Injection Side Y2 + 22, 0 [0. 87] X3 Plate features are noted on plan view and correspond to features in section view below. X4 For HT / TS For HT / TS 26. 8 [1. 06] 40. 0 [1. 57] 12. 5 [0. 49] 3. 0 MIN [. 12] 8. 000 +0. 015 [. 3150 +. 0006] *C 1/4 -20 M6 (2) *B 80. 8 [3. 18] BK-PLT *B 6. 8 [. 27] MF-PLT 6. 8 x 17. 0 DP. 42. 0 [1. 66] [ . 32 +. 0001 x . 59 DP. ] 60. 01 +0. 03 [2. 36 +. 0001] 30. 0 MAX 1. 5R [1. 18] [. 06] 44. 01 +0. 03 [1. 733 +. 001] R 1. 5 [. 06] MAX 22. 2 [. 88] T/C MF-PLT THRU HOLE FOR X> 87 mm 22. 2 [. 88] T/C MF-PLT T/C : Thermocouple BK - PLT : Manifold Backing Plate MF - PLT : Manifold Plate X : Pitch X Value Y : Pitch Y Value R, RAD : Radius C : Center Insulator Bore Depth* B : Nozzle Bore Depth* *Refer to calculator on www. hotrunners. com Please confirm all dimensions and nozzle suitability by contacting Husky. Min Pitch (X1, 2, 3, 4) Max Pitch (X1, 2, 3, 4) 53mm (2. 087") Min Pitch (Y1/Y2) 53mm (2. 087") No. [. . . ] **Depending upon pitch values, dowel location will differ. Contact Husky for specific location, otherwise include both. Step 2: Layout plate features using pitch dimension for X value For HT / TS For VG /VX M12 [1/2-13 UNC] (3 Bolts per drop recommeded) MAX MIN Sharp THRU HOLE FOR X > 87 mm T/C : Thermocouple Step 3:Section view shown above corresponds to feature callouts (Ultra 500) planview. BK - PLT : Manifold Backing Plate Gate Min X HT Max X Min Y1 Max Y1 Min Y2 Max Y2 Number of T/C's 2 T/C's Mounted Through Manifold Plate 2 T/C's Mounted 331mm Through Backing (13. 031") Plate (when required) Electrical MF - PLT : Manifold Plate Zones X : Pitch X Value Y : Pitch Y Value R, RAD : Radius 11 or 13 C : Center Insulator Bore Depth* B : Nozzle Bore Depth* *Refer to calculator on www. hotrunners. com >73. 0mm 211mm (2. 87") (8. 307") >73. 0mm 211mm (2. 87") (8. 307") >61. 3mm Y2-45mm Y1 + 62. 0mm 331mm (2. 41") (1. 771") (2. 41") (13. 031") >61. 3mm Y2-50mm (2. 41") (1. 968") Y1+ 62. 0mm (2. 41") VG Please confirm all dimensions and nozzle suitability by contacting Husky. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HUSKY MANIFOLD-SYSTEM-BOOKLET-060809

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HUSKY MANIFOLD-SYSTEM-BOOKLET-060809 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag