User manual ICOM HM-162B-SW

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

Sponsored Links

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ICOM HM-162B-SW. We hope that this ICOM HM-162B-SW user guide will be useful to you.

Lastmanuals help download the user guide ICOM HM-162B-SW.


ICOM HM-162B-SW : Download the complete user guide (169 Ko)

Manual abstract: user guide ICOM HM-162B-SW

Detailed instructions for use are in the User's Guide.

[. . . ] INSTRUCTIONS REMOTE-CONTROL MICROPHONE Thank you for purchasing the HM-162B/SW REMOTETM CONTROL MICROPHONE. The COMMANDMIC III is a remote control microphone for use with the IC-M604 or else. Please read the connected transceiver's instruction manual carefully before installation and operation. These instructions are just described the remotecontrol operations only. HM-162B/SW These instructions are described when the HM-162 is connected to the IC-M604. [. . . ] Lock functions The Lock function electronically locks keys and switches to prevent accidental changes and function access from the microphone. All keys, switches and controllers on the transceiver are functional. Clearing (or setting) all tagged channels While pushing [H/L], push [SCAN·TAG] for 3 sec. (until a long beep changes to 2 short beeps) to clear all TAG channels in the channel group. · Repeat above procedure to set all TAG channels. D Activating the Lock function While pushing [H/L], push [VOL/SQL·MONI L ] to turn the Lock function ON or OFF. ·" " appears. · Only [PWR] ([CLR]/[MENU]), [DISTRESS], [PTT], [H/L], [VOL/SQL·MONI L ] and [SELECTOR] are functional. é /2 Starting a scan Set scan type (Priority or Normal scan) and scan resume timer in advance, using Set mode. q While pushing [H/L], push [CH/WX·DW U/I/C ] several times to select the desired channel group (USA, INT or CAN). r Push [SCAN·TAG] to start PriAppears ority or Normal scan. BUSY-25W---INT---CALL BUSY 25W---INT---CALL P N · "PRI-SCAN 16"or "NORMAL LOCAL--DUP SCAN" appears during Priority SCRAM--TAG SCRAM--TAG NORMAL-SCAN NORMAL SCAN or Normal scan, respectively. [CH-] [CH -34"34. 206N 34"34. 206N · When a signal is detected, scan 123"23. 236W pauses until the signal disap--UTC 10:10COMMERCIAL --UTC-10:10COMMERCIAL pears or resumes after pausing During normal scan 5 sec. according to the Set mode setting (Channel 16 is still monitored during Priority scan). · Rotate [SELECTOR CH] to check the scanning TAG channels, to change the scanning direction or resume the scan manually. 1 · "16" blinks at the channel comment indicator and a beep tone sounds when a signal is received on Channel 16 during Priority scan. BUSY-25W---INT---CALL 25W---INT---CALL LOCAL--DUP LOCAL--DUP SCRAM--TAG SCRAM--TAG NORMAL-SCAN [CH-] -34"34. 206N 34"34. 206N 123"23. 236W --UTC 10:10--UTC-10:10- INTL Appears D Activating the All Key Lock function While pushing [H/L], turn the power ON by pushing [PWR] to turn the All Key Lock function ON or OFF. ·" " blinks. · Only [PWR] ([CLR]/[MENU]), [DISTRESS] and [PTT] are functional. é BUSY-25W---INT---CALL 25W---INT---CALL LOCAL--DUP LOCAL--DUP SCRAM--TAG SCRAM--TAG NORMAL-SCAN [CH-] -34"34. 206N 34"34. 206N 123"23. 236W --UTC 10:10--UTC-10:10- INTL Blinks t To stop the scan, repeat step r. 4 /3 Display backlight The function display and keys can be backlit for better visibility under low light conditions. The backlighting condition can also be adjusted independently from the transceiver. While pushing [H/L], rotate [SELECTOR] to adjust the backlight level. B · "BACKLIGHT " with the backlight level appears. · The backlight is adjustable in 7 levels and OFF. BUSY-25W---INT---CALL 25W---INT---CALL LOCAL--DUP SCRAM--TAG SCRAM--TAG NORMAL-SCAN BACKLIGHT -7 -<ENT OK> <ENTOK> COMMERCIAL /6 Hailer function q Push [HAIL· RX ] to enter the hailer mode. w Push and hold [PTT] and speak at a normal voice level. BUSY-25W---INT---CALL LOCAL--DUP SCRAM--TAG NORMAL-SCAN HAILER LISTEN 15. 236W 15. 236W ____al--1:10--CALLING ___ l--1:10--CALLING T · "TALK" appears. W · "WAIT" appears while the transceiver side is in use. · To adjust the hailer level, rotate [SELECTOR]. Appears e After speaking, release [PTT]. r To cancel the hailer mode, repeat step q. · Pushing [16·9] also cancels the hailer function. /4 RX Speaker function q Push [HAIL· RX ] for 1 sec. to enter the RX Speaker mode. BUSY-25W---INT---CALL BUSY 25W---INT---CALL LOCARX UP LOCARX--UP SCRAM--TAG SCRAM--TAG NORMAL-SCAN RXRX [CH-] [CH 154"34. 206N 154"34. 206N 123"23. 236W -<ENT OK>-- CALLING <ENTOK>-- While in the hailer mode, the transceiver functions (transmit and receive) are interrupted. If the transceiver is in transmit condition, the hailer function is not available. · " RX " indicator appears. · The audio output level for the RX speaker can be adjusted when entering this mode. [. . . ] · 1st digit `0' is fixed for a group ID. e After inputting, push [ENT] to program. r Push [CLR] or select "Exit" in the set up menu then push [ENT]. · Returns to the DSC menu. · Repeat again to return to the normal operation condition. D Transmitting a polling request call P q Select and enter "Polling Request " in the DSC menu. r Push [CLR] to return to the previous indication before entering the DSC menu. · Even if [CLR] hasn't been pushed, the display automatically returns to the previous indication after 2 sec. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ICOM HM-162B-SW

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ICOM HM-162B-SW will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag