User manual ICOM HM-162E

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

Sponsored Links

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ICOM HM-162E. We hope that this ICOM HM-162E user guide will be useful to you.

Lastmanuals help download the user guide ICOM HM-162E.


ICOM HM-162E : Download the complete user guide (141 Ko)

Manual abstract: user guide ICOM HM-162E

Detailed instructions for use are in the User's Guide.

[. . . ] INSTRUCTIONS REMOTE-CONTROL MICROPHONE Thank you for purchasing the HM-162E REMOTETM CONTROL MICROPHONE. The COMMANDMIC III is a remote control microphone for use with the IC-M603 or else. Please read the connected transceiver's instruction manual carefully before installation and operation. These instructions are just described the remotecontrol operations only. HM-162E These instructions are described when the HM-162E is connected to the IC-M603. [. . . ] 1 · "16" blinks at the channel comment indicator and a beep tone sounds when a signal is received on Channel 16 during Priority scan. r Rotate [SELECTOR DIAL] to select the desired channel. BUSY-25W---INT---CALL LOCAL--DUP SCRAM--TAG NORMAL-SCAN [DIAL] -34"34. 206N 123"23. 236W --UTC-10:10- INTL BUSY-25W---INT---CALL LOCAL--DUP SCRAM--TAG NORMAL-SCAN [DIAL] -34"34. 206N 123"23. 236W --UTC-10:10- INTL t Push [16·C] to program the displayed channel as the call channel. · The channel number stops blinking. Dualwatch/Tri-watch operation q Select Dualwatch or Tri-watch in Set mode. w Rotate [SELECTOR DIAL] after pushing [DIAL·DW select the desired channel. GRP ] to · While pushing [H/L], push [DIAL·DW GRP ] several times to select the channel group (depending on the connected transceiver's version), if desired. e Push [DIAL·DW GRP ] for 1 sec. to start Dualwatch or Tri-watch. D · "DUAL 16" appears during DuT alwatch; "TRI 16 " appears during Tri-watch. · Tri-watch becomes Dualwatch when receiving a signal on the call channel. Appears BUSY-25W---INT---CALL BUSY 25W---INT---CALL LOCAL--DUP SCRAM--TAG SCRAM--TAG ----DUAL 16 ----DUAL-16 [VOL] -34"34. 206N 34"34. 206N 123"23. 236W --UTC 10:10COMMERCIAL --UTC-10:10COMMERCIAL t To stop the scan, repeat step r. /2 Monitor function The monitor function releases the noise squelch mute of the microphone only. (An independent noise squelch system is employed. ) Push [VOL/SQL·MONI L ] for 1 sec. to activate the Monitor function. B · "BUSY" blinks and audio is emitted. · [VOL/SQL·MONI L ] (or [ENT], [CLR]) cancels the Monitor function. Blinks BUSY-25W---INT---CALL BUSY 25W---INT---CALL LOCAL--DUP SCRAM--TAG SCRAM--TAG NORMAL-SCAN [VOL] -34"34. 206N 34"34. 206N 123"23. 236W --UTC 10:10COMMERCIAL --UTC-10:10COMMERCIAL r To cancel Dualwatch or Tri-watch, push [DIAL·DW again. GRP ] 4 /3 Display backlight The function display and keys can be backlit for better visibility under low light conditions. The backlighting condition can also be adjusted independently from the transceiver. While pushing [H/L], rotate [SELECTOR] to adjust the backlight level. B · "BACKLIGHT " with the backlight level appears. · The backlight is adjustable in 7 levels and OFF. BUSY-25W---INT---CALL 25W---INT---CALL LOCAL--DUP SCRAM--TAG SCRAM--TAG NORMAL-SCAN BACKLIGHT -7 -<ENT OK> <ENTOK> COMMERCIAL /7 Intercom operation q Push [IC] to activate the Intercom function. w Push and hold [PTT] to talk. I · "INTERCOM TALK" appears. BUSY-25W---INT---CALL BUSY-25W---INT---CALL LOCAL--DUP SCRAM--TAG SCRAM--TAG NORMAL-SCAN INTERCOM TALK 123"23. 236W --UTC-10:10COMMERCIAL --UTC-10:10COMMERCIAL BUSY-25W---INT---CALL BUSY-25W---INT---CALL LOCAL--DUP SCRAM--TAG SCRAM--TAG NORMAL-SCAN INTERCOM LISTEN 123"23. 236W --UTC-10:10COMMERCIAL --UTC-10:10COMMERCIAL e Release [PTT] to listen. I · "INTERCOM LISTEN " appears when the transceiver is in talking mode. · To adjust the audio outoput level, push [VOL/SQL] then rotate [SELECTOR VOL]. Appears /4 RX Speaker function q Push [HAIL·RX ] for 1 sec. to enter the RX Speaker mode. BUSY-25W---INT---CALL BUSY 25W---INT---CALL LOCARX UP LOCARX--UP SCRAM--TAG SCRAM--TAG NORMAL-SCAN RXRX [CH-] [CH 154"34. 206N 154"34. 206N 123"23. 236W -<ENT OK>-- CALLING <ENTOK>-- r Push [IC] to cancel the Intercom function. · Pushing [16·C] also cancels the Intercom function. · " RX " indicator appears. · The audio output level for the RX speaker can be adjusted when entering this mode. Or while pushing [HAIL·RX ], rotate [SELECTOR] before tuning this function OFF (within 1 sec. ). For your reference: In case the Intercom mode is selected with the transceiver while the microphone power is OFF, the microphone power is automatically turned ON and the Intercom mode is selected. D Intercom beep function Push and hold [IC] for more than 1 sec. · Emits the Intercom beep while holding. w To cancel the RX Speaker mode, repeat step q. · " RX " indicator disappears. /5 Hailer function q Push [HAIL·RX ] to enter the hailer mode. w Push and hold [PTT] and speak at a normal voice level. BUSY-25W---INT---CALL LOCAL--DUP SCRAM--TAG NORMAL-SCAN HAILER LISTEN 15. 236W 15. 236W ____al--1:10--CALLING ___ l--1:10--CALLING /8 Automatic foghorn The automatic foghorn function sounds a horn repeatedly until the function is turned OFF. To use this function, the hailer speaker must be connected to the transceiver. q While pushing and holding [H/L], push [HAIL·RX ] to enter auto foghorn mode. w Rotate [SELECTOR] to select the desired foghorn pattern, push [ENT]. U S S · `UNDERWAY, ' `STOP, ' `SAIL, ' T `TOW' are available. · Even if [ENT] hasn't been pushed, the display automatically changes to the next step after 5 sec. [. . . ] · 1st digit `0' is fixed for a group ID. e After inputting, push [ENT] to program. r Push [CLR] or select "Exit" in the set up menu then push [ENT]. · Returns to the DSC menu. · Repeat again to return to the normal operation condition. D Transmitting a polling request call P q Select and enter "Polling Request " in the DSC menu. r Push [CLR] to return to the previous indication before entering the DSC menu. · Even if [CLR] hasn't been pushed, the display automatically returns to the previous indication after 2 sec. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ICOM HM-162E

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ICOM HM-162E will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag