User manual ICOM IC-2SRE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ICOM IC-2SRE. We hope that this ICOM IC-2SRE user guide will be useful to you.

Lastmanuals help download the user guide ICOM IC-2SRE.


Mode d'emploi ICOM IC-2SRE
Download
Manual abstract: user guide ICOM IC-2SRE

Detailed instructions for use are in the User's Guide.

[. . . ] q Hand microphone (HM-151) . . . . . . . . . . . . . . . . . . . . . . . . 1 w DC power cable* (OPC-1457) . . . . . . . . . . . . . . . . . . . . . 1 e Spare fuse (ATC 5 A) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 r Spare fuse (ATC 30 A) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] to toggle between RTTY and RTTY-R modes. RTTY mark frequency is set to 2125 Hz. (default) 2125, 1615 and 1275 Hz are available. w Push [AF(SET)] momentarily to enter the set mode menu. e Push [F-1 QS] to enter the quick set mode. R r Push [F-1 Y] or [F-2 Z] to select "RTTY Mark Frequency. " t Rotate [DIAL] to select the desired frequency. · Push and hold [F-4 DEF] for 1 sec. to select the default frequency. 4 RTTY shift width is set to 170 Hz. (default) 170/200/425 Hz are available. Shift width q Enter the quick set mode as above. R w Push [F-1 Y] or [F-2 Z] to select "RTTY Shift Width. " e Rotate [DIAL] to select the desired shift width. · Push and hold [F-4 DEF] for 1 sec. to select the default shift width. RTTY keying is set to `normal'. (default) normal : key open=mark key close=space reverse: key open=space key close=mark RTTY keying polarity q Enter the quick set mode as above. R w Push [F-1 Y] or [F-2 Z] to select "RTTY key ing Polarity. " e Rotate [DIAL] to select the desired keying polarity. · Push and hold [F-4 DEF] for 1 sec. to select the default polarity. Z After Pre-setting is finished, push [Z(MENU/GRP)] twice to return the normal operating mode. 56 4 RECEIVE AND TRANSMIT Operating AM Z Y q Push [Y(BAND)]/[Z(BAND)] to select the desired band or push a band key on the HM-151. 82) S While "S-1" is selected, push [F-4 VSC] to turn the VSC function ON and OFF. ·" " appears when VSC function is set to ON. Push and hold [MNF/ADJ] for 1 sec. to enter the manual notch filter set mode. · Push [F-2 NF1], [F-3 NF2] to select the notch filter, push [F-4 NW] to set the filter width, rotate [DIAL] to set the notch frequency. 4 D Convenient functions for transmit · Transmit quality monitor (p. 87) Push [AF(SET)], then [F-4 OTH] to enter the miscellaneous (others) set mode. Select an item with [F-1 ]/[F-2 ], then rotate [DIAL] to turn the monitor function ON and OFF. · VOX (voice operated transmit) (p. 83) M While "M-3" is selected, push [F-1 VOX] to turn the VOX function ON and OFF. · Push and hold [MENU/GRP] for 1 sec. once or twice to select the menu group M. · Push [MENU/GRP] momentarily one or more times to select the menu M-3. ·" " appears when the VOX function is set to ON. M While "M-3" is selected, push and hold [F-1 VOX] for 1 sec. to enter the VOX set mode. · Push [F-1 ]/[F-2 ] to select an item. · Rotate [DIAL] to set the value/conditions. 58 4 RECEIVE AND TRANSMIT Operating FM Y Z q Push [Y(BAND)]/[Z(BAND)] to select the desired band or push a band key on the HM-151. [. . . ] Has automatic tuning and band selection capability. Full break-in (QSK) operation is possible. The amplifier/power supply unit and the remote control unit are separated. An optional OPC-599 is required for connection. 19 150 20 MENU GUIDE Main menu group M-1 SPL A/B FIL XFC M-2 MEM MW MCL V/M M-3 VOX COM AGC TBW (SSB) BRK 1/4 AGC 1/4 AGC VOX AGC (CW) (RTTY) (AM) Sub menu group S-1 VO MET VSC (SSB/AM) (CW) VO KEY MET VSC (RTTY) VO DEC MET VSC VO DTM MET VSC (FM/WFM) S-2 SCN PRI V/M VSC SEL (in memory mode) VOX DUP TON 9600 (FM/WFM) S-3 MW MPW MPR G-1 BAND scope Multi function meter G-2 G-3 BAND scope Multi function meter SWR meter Graphic menu group Push [AF] momentarily Push momentarily Push for 1 sec. Push [Z(MENU/GRP)] to exit Set mode menu 151 MENU GUIDE 20 Set mode description · Set mode menu · Miscellaneous (others) set mode Push [Z(MENU/GRP)] or [AF] switch to return to upper menu · Display set mode · Time set mode Quick set mode No. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ICOM IC-2SRE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ICOM IC-2SRE will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag