User manual ICOM IC-40S

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ICOM IC-40S. We hope that this ICOM IC-40S user guide will be useful to you.

Lastmanuals help download the user guide ICOM IC-40S.


Mode d'emploi ICOM IC-40S
Download
Manual abstract: user guide ICOM IC-40S

Detailed instructions for use are in the User's Guide.

[. . . ] TRANSCEIVER i40S FOREWORD READ ALL INSTRUCTIONS carefully and completely before using the transceiver. CAUTIONS R WARNING!NEVER hold the transceiver so that the antenna is very close to, or touching exposed parts of the body, especially the face or eyes, while transmitting. The transceiver will perform best if the microphone is 5 to 10 cm away from the lips and the transceiver is vertical. SAVE THIS INSTRUCTION MANUAL -- This instruction manual contains important operating instructions for the IC-40S. R WARNING!NEVER operate the transceiver with a headset or other audio accessories at high volume levels. [. . . ] [PTT] and the backlight function can be used while the lock function is in use. · If "T SQL" appears on the display, push [­] for 2 sec. twice to cancel the tone squelch function. r Release [PTT] to receive. t To cancel the duplex setting, push [DUP] on the desired channel. (Unit: Hz) 7 4 SCAN OPERATION s Open scan Open scan searches for transmitted signals automatically and makes it easier to locate new stations for contact or listening purposes. During open scan, transmission is not possible except on a busy channel. q Push [O/G] to select open scan. - "OS" appears when the open scan is selected. s Scan types The transceiver has 3 scan types with tag functions and 4 resume conditions providing scanning versatility. Tag channels are independently set for open, group and priority scans. Initially, all channels may be set as tag channels for all scans. OPEN SCAN X ch 40 ch 4 X ch 1 ch 2 X ch 3 w Push [SCN] to start open scan. - Cancelling tag channels speeds up the scan interval. 9) Start channel MR X ch 39 X ch 6 X ch 5 Repeatedly scans all tag channels in sequence. GROUP OR PRIORITY SCAN X ch 8 Scanning channel is displayed. Priority channel X ch 12 X ch 26 e When receiving a signal, scan pauses and resumes according to the selected scan resume condition. 10) r Push [SCN] to stop the scan. Repeatedly watches a priority channel while scanning only specified channels (tag channels). 8 SCAN OPERATION 4 s Group and priority scans Group and priority scans repeatedly watch a priority channel while scanning only specified channels. This is useful when waiting for calls on the priority channel or several specified channels. Group and priority scans behave differently when transmitting. During group scan, transmission is possible on a busy channel only. During priority scan, transmission is possible on a priority channel (or start channel) only. q Push [O/G] to select open scan. - "GS" or "PS" appears when the group or priority scan is selected, respectively. Start channel MR s Setting scan tag Scan tag must be set before starting scan. Tag channels are independently set for open, group and priority scan. w Push [O/G] to select the desired scan type. to set the channel as a tag channel. - "X" appears for tag channels. r Repeat step e to cancel the tag channel setting. Appears for channels to be scanned. MR SCN for 2 sec. w Select the priority channel if desired. - Push [Y] or [Z] key to select a channel. [. . . ] ch. ) : FM (16K0F3E) : 25 kHz : 9. 6 V DC nominal (authorized battery packs) : ­10°C to +60°C : ±5 ppm : at 5 W 1. 6 A at 1 W 0. 7 A standby 60 mA max. audio 250 mA power saved 13 mA : 50 (nominal) : 57(W) 140(H) 37(D) mm : 370 g · Output power · Modulation · Max. frequency deviation · Spurious emissions · Adjacent channel power · External mic. 5 W (at 9. 6 V DC) : Variable reactance frequency modulation : ±5 kHz : 70 dB typical : 70 dB typical : 3-conductor 2. 5 (d) mm/2 k D General · Frequency coverage · Mode · Tuning step increment · Acceptable power supply (negative ground) · Usable temp. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ICOM IC-40S

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ICOM IC-40S will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag