User manual ICOM IC-4GE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ICOM IC-4GE. We hope that this ICOM IC-4GE user guide will be useful to you.

Lastmanuals help download the user guide ICOM IC-4GE.


Mode d'emploi ICOM IC-4GE
Download
Manual abstract: user guide ICOM IC-4GE

Detailed instructions for use are in the User's Guide.

[. . . ] CAUTION NOTE Equipment damage may occur. No risk of personal injury, fire or electric shock. WORD D FEATURES Built-in DSC meets ITU Class D requirement Rugged waterproof construction Large LCD with dot matrix characters Front and rear panel microphone connection Optional COMMANDMICIITM (HM-157) and COMMANDMICIIITM (HM-162) are available and up to two COMMANDMICTMs can be connected Icom, Icom Inc. and the logo are registered trademarks of Icom Incorporated (Japan) in the United States, the United Kingdom, Germany, France, Spain, Russia and/or other countries. [. . . ] 43) q While pushing and holding [H/L], push [CH/WX] several times to select the channel group, if desired. w Set TAG channels as described at left. e Make sure the squelch is closed to start a scan. r Push [F], then push [4· SCN ] to start Priority or Normal scan. P N · "PRI-SCAN 16" or "NORMAL SCAN" appears in the display. · When a signal is detected, scan pauses until the signal disappears or resumes after pausing 5 sec. (Channel 16 is still monitored during Priority scan. ) YZ · Rotate [SELECTOR] or push [Y]/[Z] on the microphone to check the scanning TAG channels, to change the scanning direction or resume the scan manually. 1 · A beep tones sounds and "16" blinks when a signal is received on Channel 16 during Priority scan. 5 r To cancel the TAG channel setting, repeat step e. T · "TAG" disappears. Clearing (or setting) all tagged channels While pushing and holding [H/L], push [5· TAG ] for 3 sec. (until a long beep changes to 2 short beeps) to clear all TAG channels setting in the selected channel group. · Repeat above procedure to set all channels as TAG channels. t To stop the scan, push [CLR] or repeat step r. [Example]: Starting a normal scan. 25W INT DUP Push then push Scan starts. INT DUP TAG NORMAL SCAN 34°34. 506N 34 34. 506N 123°23. 236W 123 23. 236W UTC 12:00 12:00 25W When a signal is received BUSY 25W INT DUP NORMAL SCAN 34°34. 506N 34 34. 506N 123°23. 236W 123 23. 236W UTC 12:00 12:00 34°34. 506N 34 34. 506N 123°23. 236W 123 23. 236W UTC 12:00 12:00 INTL SAFETY 15 6 DSC OPERATION I DSC address ID A total of 100 DSC address IDs can be programmed and named with up to 10 characters. I MMSI code programming The 9-digit MMSI (Maritime Mobile Service Identity: DSC self ID) code can be programmed at power ON. This code programming can be performed only twice. q While pushing and holding [MENU], push [POWER] to enter MMSI code programming condition. · Turn power OFF in advance. D Programming Individual ID A q Enter "Add:INDV ID" in DSC Set up menu. D S A DSC Menu Set up Add:INDV ID (Push [MENU]) (Rotate [SELECTOR], then push [ENT]. ) w After the display appears, release [MENU]. Then edit the current UTC time with the keypad. · Rotate [SELECTOR] to move the cursor backward or forward. · Push [CLR] to cancel and exit the condition. --DSC Menu-Input UTC Time __:__ Null w Edit your position (latitude and longitude) data directly with the keypad. · Push [6·MNO] to edit N; North latitude or [7·PRS] to edit S; South latitude. · Push [3·DEF] to edit E; East longitude or [9·WXY] to edit W; West longitude. · Rotate [SELECTOR] to move the cursor backward or forward. · Push [CE] to clear the position data. · Push [CLR] to cancel and exit the condition. <CENull <CE Null Data> <CLRExit <CLR Exit / ENT OK> ENTOK> r Push [ENT] to set the time and return to the DSC menu. E t Push [CLR] or rotate [SELECTOR] to select "Exit , " push [ENT] to return to the normal operation condition. 18 DSC OPERATION 6 I Position and Time indication When a GPS receiver (NMEA0183 ver. 2. 0 or 3. 01) is connected, the transceiver displays the current position and time. When no GPS receiver is connected, the transceiver displays the manually entered position and time. A GPS receiver appropriate for the IC-4GE is not supplied from Icom. 2. 0 or 3. 01 format is required for position and time indication. [. . . ] · Internal speaker is turned OFF. · The Attenuator is activated. Transmitting is impossi- · Some channels are programmed for low · Change channels. ble, or high power can power or receive only in regulations. · The output power is set to low. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ICOM IC-4GE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ICOM IC-4GE will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag