User manual ICOM IC-728-729

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ICOM IC-728-729. We hope that this ICOM IC-728-729 user guide will be useful to you.

Lastmanuals help download the user guide ICOM IC-728-729.


Mode d'emploi ICOM IC-728-729
Download
Manual abstract: user guide ICOM IC-728-729

Detailed instructions for use are in the User's Guide.

[. . . ] AVOID placing the transceiver against walls or putting anything on top of the transceiver. During mobile operation, DO NOT operate the transceiver without running the vehicle's engine. When transceiver power is ON and your vehicle's engine is OFF, the vehicle's battery will soon become exhausted. Make sure the transceiver power is OFF before starting the vehicle. [. . . ] RIT function can be used for the main readout only. TX function can be used for the transmit readout (main readout when the split function is OFF; sub readout when the split function is ON). 9 2. 4k TX 455 2. 8k USB 1ß 14. 100. 00 DUAL-W 12:34 USB VFO 21. 290. 00 USB 56ß VFO 14. 100. 00 21. 290. 00 USB · Scanning during dualwatch Scanning operates only for the main readout. To operate the scan during dualwatch, scan on the main readout and use the sub readout for your QSO using both dualwatch and split frequency operation. q Program the desired programmed scan edges in the same amateur band. 43 for programming. - If you plan to operate a F scan, programming the scan edges may not be necessary. t Push [DUALWATCH] for 2 sec. - The main and sub readout frequencies are equalized and the dualwatch function is turned ON. ANT 1 METER Po Po P. AMP OFF TX 9 2. 4k 455 2. 8k USB VFO 1ß 14. 100. 00 SPLIT DUAL-W 12:34 USB 21. 290. 00 USB ATT OFF VFO 1ß 14. 100. 00 21. 290. 00 USB w Push [SPLIT] to turn the split frequency function ON. - " SPLIT " appears. ANT 1 METER Po Po P. AMP OFF TX y Push [(F-4)SCAN] to select the scan screen. - If the start up screen is not selected (if [F-5]'s function is [EXIT]), push [F-5] one or more times to exit. 9 2. 4k 455 2. 8k USB VFO 1ß 14. 100. 00 SPLIT 12:34 USB u Push [(F-1)PROG] or [(F-2)F] to start the programmed scan or F scan, respectively. - Scan activates on the main readout between the programmed scan edges or within the F span. - Transmitting on the sub readout stops the scan. ANT 1 METER Po Po 21. 290. 00 USB ATT OFF VFO 14. 205. 00 1ß 14. 100. 00 USB 9 2. 4k 455 2. 8k USB VFO 1ß 14. 100. 00 SPLIT TX 12:34 USB e Select VFO mode for the main readout. r Set the desired operating frequency for the main readout. 21. 250. 00 DUAL-W P. AMP OFF ATT OFF AGC MID VOX OFF COMP OFF OFF USB VFO 1ß 14. 100. 00 [SCAN] PROGRAM SCAN 21. 290. 00 USB F Span : ± 10kHz Programmed P1: 0. 500. 00MHz Scan edges P2: 29. 999. 99MHz PROG F FINE FSPAN FSPAN EXIT i To cancel the scan, push [(F-5)EXIT]. 30 4 RECEIVE AND TRANSMIT s Split frequency operation Split frequency operation allows you to transmit and receive in the same mode on two different frequencies. The split frequency operation is basically performed using 2 frequencies on the main and sub readouts. Following is an example of setting 21. 290 MHz for receiving and 21. 310 MHz for transmitting. q Set 21. 290 MHz (USB) in VFO mode. ANT 1 METER Po Po P. AMP OFF ATT OFF CONVENIENT DIRECT SHIFT FREQUENCY INPUT The shift frequency can be entered directly. - Or, rotate the tuning dial. OPERATION 2 If the DX station says "down 5 kHz" before you enter standby for split operation: · Push [F-INP], [ · ], [5] then [SPLIT]. - The split function is turned ON and "5 kHz down" frequency is entered in the sub readout. 32 4 RECEIVE AND TRANSMIT s Monitor function The monitor function allows you to monitor your transmit IF signals in any mode through the speaker. Use this to check voice characteristics while adjusting transmit tones. 54) The CW sidetone functions regardless of the [MONITOR] switch setting. q Push [MONITOR]. - The indicator lights when the monitor function is ON. [MONITOR] switch [PHONES] jack w If the start up screen is not selected (if [F-5]'s function is [EXIT]), push [F-5] one or more times to exit. e Push [(F-5)SET] then [(F-1)LEVEL] to enter level set mode. r Push [(F-1)Y] or [(F-2)Z] to select the monitor adjustment item. t Adjust monitor gain using the tuning dial. - Pushing [(F-3)DEF] sets the selected item to the default value of the item. ANT 1 METER Po Po P. AMP OFF ATT OFF AGC MID VOX OFF COMP OFF OFF 9 2. 4k TX 455 2. 8k USB 1ß 14. 100. 00 USB USB 12:34 VFO 14. 195. 00 14. 205. 00 USB 0dB 0dB 50% 50% VFO 1ß 14. 100. 00 [LEVEL SET] TX tone (Bass) TX tone (Treble) Monitor Beep y Push [(F-5)EXIT] twice to exit level set mode. · Use headphones to prevent feedback. · Set the transmit tone settings to the 0 dB positions to check the unaltered characteristics of transmitter or microphone. DEF DEF EXIT s VOX function The VOX (Voice-Operated Transmission) function toggles between transmit and receive with your voice. This function provides an opportunity to input log entries into your computer, etc. , while operating. [VOX] switch in phone modes · Using the VOX function q Select a phone mode (SSB, AM, FM). [. . . ] !0 Push [(F-5)EXIT] twice to exit set mode. 65 INTERNAL VIEWS · Top view 11 PA unit Internal antenna tuner PA fuse (FGB 5 A) FILTER unit Clock backup battery · Bottom view Reference freq. check point (cable from J81; 60. 000 MHz) RF unit Space for optional 9 MHz filter Space for optional 455 kHz filter R572 Optional voice synthesizer level adj. Space for optional high-stability crystal unit (CR-502) PLL unit Space for optional voice synthesizer (UT-102) MAIN unit 66 12 SPECIFICATIONS s General · Frequency coverage: Receive 10. 030­60. 000 MHz*1 Transmit 01. 800­01. 999 MHz*2 03. 500­13. 999 MHz*2 07. 000­17. 300 MHz*2 10. 100­10. 150 MHz 14. 000­14. 350 MHz 18. 068­18. 168 MHz 21. 000­21. 450 MHz 24. 890­24. 990 MHz 28. 000­29. 700 MHz 50. 000­54. 000 MHz*2 *1 Some frequency bands are not guaranteed. *2 1. 830­1. 850, 3. 500­3. 800, 7. 000­7. 100, 50. 200­51. 200 for France version. · Microphone connector: 8-pin connector (600 ) · ELEC-KEY connector : 3-conductor 6. 35(d) mm (1/4") · KEY connector : 3-conductor 6. 35(d) mm (1/4") · SEND connector : Phono (RCA) · ALC connector : Phono (RCA) s Receiver · Intermediate frequencies: SSB 1st 2nd 3rd 4th CW, RTTY AM FM 69. 0115 MHz 69. 0106 MHz 69. 0100 MHz 69. 0115 MHz 9. 0115 MHz 9. 0106 MHz 9. 0100 MHz 9. 0115 MHz 455 kHz 455 kHz 455 kHz 455 kHz -- 15. 625 kHz 15. 625 kHz 15. 625 kHz : USB, LSB, CW, RTTY, AM, FM · Number of memory : 101 (99 regular, 2 scan edges) channels · Antenna connector : PL-239 × 2 and phono (RCA, 50 ) · Usable temperature : ­10°C to 60°C (14°F to 140°F) range · Frequency stability : Less than ± 200 Hz from 1 min. After that rate of stability less than ± 30 Hz/hr. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ICOM IC-728-729

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ICOM IC-728-729 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag