User manual ICOM IC-AG-35

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ICOM IC-AG-35. We hope that this ICOM IC-AG-35 user guide will be useful to you.

Lastmanuals help download the user guide ICOM IC-AG-35.


Mode d'emploi ICOM IC-AG-35
Download
Manual abstract: user guide ICOM IC-AG-35

Detailed instructions for use are in the User's Guide.

[. . . ] q Hand microphone (HM-151) . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 w DC power cable (OPC-1457) . . . . . . . . . . . . . . . . . . . . . . . . . . 1 e Spare fuse (ATC 5 A) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 r Spare fuse (ATC 30 A) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] w Push [F-3 ADJ] to select the threshold level setting condition. e Rotate [DIAL] to adjust the RTTY decoder threshold level. · Push and hold [F-4 DEF] for 1 sec. to select the default condition. Z r Push [Z(MENU/GRP)] to exit the RTTY decoder screen. [MENU/GRP] [F-3] [F-4] [DIAL] The UnShift On Space (USOS) function and new line code can be set in the RTTY decode set mode. 55) 54 4 RECEIVE AND TRANSMIT D RTTY decode set mode This set mode is used to set the decode USOS function, etc. q Push [MODE] momentarily to select RTTY mode. · After RTTY mode is selected, push [MODE] for 1 sec. to toggle between RTTY and RTTY-R modes. w Select S-1. · Push and hold [MENU/GRP] for 1 sec. once or twice to select the menu group S. · Push [MENU/GRP] momentarily one or more times to select the menu S-1. [MENU/GRP] [F-1] [F-2] [F-4] [DIAL] e Push [F-2 DEC] momentarily to turn the RTTY decoder ON. · RTTY decoder screen appears. r Push [F-4 SET ] to select the RTTY decode set mode. t Push [F-1 ] or [F-2 ] to select the desired set item. y Set the desired condition using [DIAL]. · Push [F-4 DEF] for 1 sec. to select a default condition or value. Z u Push [Z(MENU/GRP)] to exit from set mode. 1 RTTY Decode USOS This item selects the USOS (UnShift On Space) function of the internal RTTY decoder. 74) M While "M-3" is selected, push [F-3 AGC] momentarily one or more times to select AGC fast, AGC middle and AGC slow. · Push and hold [MENU/GRP] for 1 sec. once or twice to select the menu group M. · Push [MENU/GRP] momentarily one or more times to select the menu M-3. ·" , " " " and " " appears when the fast time constant, middle time constant and slow time constant is selected, respectively. · Twin PBT (passband tuning) (p. 77) Push [PBT/M-ch/RIT] (switch) momentarily once or twice to select the twin PBT ON or OFF (M-ch RIT). · PBT indicator lights green when the twin PBT is selected. M While "M-3" is selected, push and hold [F-3 AGC] for 1 sec. to enter the AGC set mode. · Push [F-2 FAST], [F-3 MID] or [F-4 SLOW] to select the time constant, then rotate [DIAL] to adjust the time constant. Rotate [PBT/M-ch/RIT] (controls­inner/outer). · Push [PBT/M-ch/RIT(CLR)] to clear the settings. · Noise blanker (p. 78) Push [NB/ADJ] to turn the noise blanker ON and OFF. ·" " appears when the noise blanker is set to ON. Push and hold [NB/ADJ] for 1 sec. to enter the noise blanker set mode, then rotate [DIAL] to adjust the threshold level, or noise pulse width. 57 RECEIVE AND TRANSMIT 4 Convenient functions for receive (continued) · DSP noise reduction (p. 79) Push [NR/LEV] to turn the DSP noise reduction ON and OFF. ·" " appears when the DSP noise reduction is set to ON. · Auto notch filter (p. 80) Push [ANF/· REC] to turn the auto notch filter ON and OFF. ·" " appears when the auto notch filter is set to ON. Push [NR/LEV] for 1 sec. to enter the noise reduction level set mode, then rotate [DIAL] to adjust the DSP noise reduction level. [. . . ] 2E / 2F Description Numerals Alphabetical characters Word space Symbol Symbol Symbol D Split/Duplex frequency setting The following data sequence is used when sending/reading the split or duplex frequency setting. q X 0 X w X 0 e X r* XX 10 MHz digit: 0 (fixed) 100 Hz digit: 0 (fixed) 100 kHz digit: 0--9 10 kHz digit: 0--9 1 MHz digit: 0--4 X 1 Hz digit: 0­9 e X 2nd digit: 0­7 1 kHz digit: 0--9 D Codes for memory name contents To send or read the desired memory name settings, the character codes, instruction codes for memory keyer contents as above, and the following are used. · Character codes-- Alphabetical characters Character ASCII code Character ASCII code a­z 61­7A -- -- · Character codes-- Symbols Character ASCII code Character !3F " ' 27 ` + 2B ­ : 3A ; = 3D < > 3E ( ) 29 [ ] 5D { } 7D | ­ _ 5F @ 40 *No need to enter for duplex frequency setting. ASCII code 23 25 5C 22 60 2D 3B 3C 28 5B 7B 7C 7E D Repeater tone/tone squelch frequency setting The following data sequence is used when sending/reading the DTCS code and polarity setting. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ICOM IC-AG-35

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ICOM IC-AG-35 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag