User manual ICOM IC-M505

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ICOM IC-M505. We hope that this ICOM IC-M505 user guide will be useful to you.

Lastmanuals help download the user guide ICOM IC-M505.


Mode d'emploi ICOM IC-M505
Download

You may also download the following manuals related to this product:

   ICOM IC-M505 BROCHURE (3398 ko)

Manual abstract: user guide ICOM IC-M505

Detailed instructions for use are in the User's Guide.

[. . . ] INSTRUCTION MANUAL VHF MARINE TRANSCEIVER iM505 FOREWORD Thank you for purchasing this Icom product. The IC-M505 VHF MARINE TRANSCEIVER is designed and built with Icom's state of the art technology and craftsmanship. With proper care, this product should provide you with years of troublefree operation. We want to take a couple of moments of your time to thank you for making the IC-M505 your radio of choice, and hope you agree with Icom's philosophy of "technology first. " Many hours of research and development went into the design of your IC-M505. IMPORTANT READ ALL INSTRUCTIONS carefully and completely before using the transceiver. SAVE THIS INSTRUCTION MANUAL -- This instruction manual contains important operating instructions for the IC-M505. EXPLICIT DEFINITIONS DEFINITION Personal injury, fire hazard or electric shock R WARNING! [. . . ] · Repeat again to return to the normal operation condition. M y Rotate [CHANNEL] to select "MMSI Check , " push [CHANNEL·ENTER]. --DSC Menu-Set up Add:INDV ID Add:Group ID DEL:INDV ID DEL:Group ID Offset Time MMSI Check MMSI 15 6 DSC OPERATION I MMSI code check The 9-digit MMSI (DSC self ID) code can be checked. S w Rotate [CHANNEL] to select "Set up , " push [CHANNEL·ENTER]. --DSC Menu-Select Item Position Report Polling Request Received Calls Distress Setting Set up Exit r Check the 9-digit MMSI (DSC self ID) code. --DSC Menu-MMSI Check 123456789 <CLRExit> E t Push [CLR] or rotate [CHANNEL] to select "Exit, " push [CHANNEL·ENTER]. · Returns to the DSC menu. · Repeat again to return to the normal operation condition. M e Rotate [CHANNEL] to select "MMSI Check , " push [CHANNEL·ENTER]. --DSC Menu-Set up DEL:Group ID Offset Time MMSI Check Auto ACK NMEA Output Exit 16 DSC OPERATION 6 I DSC address ID A total of 100 DSC address IDs can be programmed and named with up to 10 characters. r Rotate [CHANNEL] to set the individual ID and ID name. · Push [16·C] or [DIAL·DUAL/GRP] to move the cursor forward or backward, respectively. · Push [CLR] to cancel and return to the set up menu. F · "Full ID" appears when 100 DSC address IDs are already set. · After inputting the 9-digit MMSI number, push [CHANNEL· ENTER] or [16·C] to enter a 10-character ID name. --DSC Menu-Add:Individual ID Input 9 digits _________ Input name _________ <CLRExit / ENTOK> D Programming Individual ID q Push [MENU] to enter the DSC menu. S w Rotate [CHANNEL] to select "Set up , " push [CHANNEL·ENTER]. --DSC Menu-Select Item Position Report Polling Request Received Calls Distress Setting Set up Exit 6 A e Rotate [CHANNEL] to select "Add:INDV ID , " push [CHANNEL·ENTER]. --DSC Menu-Set up Add:INDV ID Add:Group ID DEL:INDV ID DEL:Group ID Offset Time MMSI Check t After inputting, push [CHANNEL·ENTER] to program. E y Push [CLR] or rotate [CHANNEL] to select "Exit, " push [CHANNEL·ENTER]. · Returns to the DSC menu. · Repeat again to return to the normal operation condition. 17 6 DSC OPERATION D Deleting Individual ID q Push [MENU] to enter the DSC menu. S w Rotate [CHANNEL] to select "Set up , " push [CHANNEL·ENTER]. --DSC Menu-Select Item Position Report Polling Request Received Calls Distress Setting Set up Exit r Rotate [CHANNEL] to select the desired ID name for deleting. --DSC Menu-Select ID John Paul George Michael <CLRExit / ENTOK> D e Rotate [CHANNEL] to select "DEL:INDV ID , " push [CHANNEL·ENTER]. N · When no address ID is programmed, "No ID " is displayed. Push [CLR] to exit. --DSC Menu-Set up Add:INDV ID Add:Group ID DEL:INDV ID DEL:Group ID Offset Time MMSI Check t Push [CHANNEL·ENTER] to delete the address ID and return to the set up menu. E y Push [CLR] or rotate [CHANNEL] to select "Exit, " push [CHANNEL·ENTER]. · Returns to the DSC menu. · Repeat again to return to the normal operation condition. 18 DSC OPERATION D Programming Group ID q Push [MENU] to enter the DSC menu. S w Rotate [CHANNEL] to select "Set up , " push [CHANNEL·ENTER]. --DSC Menu-Select Item Position Report Polling Request Received Calls Distress Setting Set up Exit 6 r Rotate [CHANNEL] to set the group ID and ID name. · The group ID is a unique number that you create for your group. The ID name is an associated text name for that group. · Push [16·C] or [DIAL·DUAL/GRP] to move the cursor forward or backward, respectively. · Push [CLR] to cancel and return to the set up menu. F · "Full ID" appears when 100 DSC address IDs are already set. · After entering an 8-digit ID code, push [CHANNEL·ENTER] or [16·C] to enter a 10-character ID name. · 1st digit `0' is fixed for a group ID. --DSC Menu-Add:Group ID Input 8 digits 0________ Input name _________ <CLRExit / ENTOK> 6 A e Rotate [CHANNEL] to select "Add:Group ID , " push [CHANNEL·ENTER]. --DSC Menu-Set up Add:INDV ID Add:Group ID DEL:INDV ID DEL:Group ID Offset Time MMSI Check t After inputting, push [CHANNEL·ENTER] to program. E y Push [CLR] or rotate [CHANNEL] to select "Exit, " push [CHANNEL·ENTER]. · Returns to the DSC menu. [. . . ] · Turn the beep tone ON in Set mode. · Set [SQL] to the threshold point. · MMSI (DSC self ID) code is not pro- · Program the MMSI (DSC self ID) code. grammed. 66 SPECIFICATIONS AND OPTIONS I Specifications D General · Frequency coverage · Mode · Channel spacing · Current drain (at 13. 8 V) · Power supply requirement · Frequency stability · Operating temp. range · Antenna impedance · Dimensions (Projections not included) · Weight : Tx 156. 000­161. 450 MHz Rx 156. 000­163. 425 MHz : FM (16K0G3E), DSC (16K0G2B) : 25 kHz : TX high 5. 5 A max. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ICOM IC-M505

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ICOM IC-M505 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag