User manual ICOM IC-M801E

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ICOM IC-M801E. We hope that this ICOM IC-M801E user guide will be useful to you.

Lastmanuals help download the user guide ICOM IC-M801E.


Mode d'emploi ICOM IC-M801E
Download

You may also download the following manuals related to this product:

   ICOM IC-M801E BROCHURE (1151 ko)

Manual abstract: user guide ICOM IC-M801E

Detailed instructions for use are in the User's Guide.

[. . . ] INSTRUCTION MANUAL MF/HF MARINE TRANSCEIVER iM801 E FOREWORD Thank you for purchasing this Icom product. The ICM801E MF/HF MARINE TRANSCEIVER is designed and built with Icom's superior technology and craftsmanship. With proper care, this product should provide you with years of trouble-free operation. We want to take a couple of moments of your time to thank you for making the IC-M801E your radio of choice, and hope you agree with Icom's philosophy of "technology first. " Many hours of research and development went into the design of your IC-M801E. IMPORTANT READ THIS INSTRUCTION MANUAL CAREFULLY before attempting to operate the transceiver. SAVE THIS INSTRUCTION MANUAL. [. . . ] 3. 01 format is applied to [GPS] connector. When no data is applied, input them, if possible. A distress call some times called as a "MAYDAY call. " NEVER USE THE DISTRESS CALL WHEN YOUR SHIP OR A PERSON IS NOT IN AN EMERGENCY. DISTRESS CALLS CAN BE USED ONLY WHEN IMMEDIATE HELP IS NEEDED. D Distress call operation outline · Simple distress call Push and hold [DISTRESS] for 5 sec. · Regular distress call Push and hold [DISTRESS] for 5 sec. RX MMSI 123456789 12. 345. 0 F1B GPS Lat 34 34'N SP Lon135 34'E 12:34 Exit DSC menu ******* DSC MENU ******* -------- Select -------Position Individual Group Geographical ÇD i s t r e s s Distress RLY Semi/Auto Test RX memory TX memory Set up Selt test ÇE x i t SEL OK Distress nature selection * * * * * * * Distress * * * * * * * - - - - - - - - Nature - - - - - - - ÇU n d e s i g n a t e d Fire, Explosion Flooding Collision Grounding Capsizing Sinking Disable adrift Abandoning ship Piracy attack Man overboard SEL OK Position & UTC time setting ******* Distress ******* --- Position & time ---4 34. 343N Latitude Longitude 135 34. 343E 12:34 UTC Null OK Frequency selection ******* Distress ******* -------- Attempt ------ÇS i n g l e ; s i x f r e q u e n c y Single; 2187. 5kHz Single; 4207. 5kHz Single; 6312. 0kHz Single; 8414. 5kHz Single;12577. 0kHz Single;16804. 5kHz SEL OK 16 CALL PROCEDURE 7 D Simple distress call NOTE: · Distress alert (simple operation) contains (default); Distress nature : Undesignated distress. Position data : According to the displayed information. · Distress call repeats every 3. 5­4. 5 min. , until receiving an acknowledgement. q Confirm a distress call is not being received. w Lift up the distress switch cover, push [DISTRESS] for 5 sec. to transmit the distress call. · An emergency frequency (default: 8414. 5 kHz) is automatically selected and the distress call is transmitted. · If you have time, select the nature of the distress and contents (p. · When no position and time data is applied to [GPS], your location and UTC time should be input. [DISTRESS] e After transmitting the call, the transceiver is set to the phone emergency frequency automatically (e. g. 8291. 0 kHz). · The DSC receiver circuit is still working to receive an acknowledgement call on the previous frequency (e. g. 8414. 5 kHz). RX < Wait for ACK > J3E GPS Lat 34 34'N Lon135 34'E 12:34 Exit r When receiving an acknowledgement, push [CANCEL] to stop the alarm then reply to the connected station via the transceiver's handset or microphone. RX < Push 5sec. > 8. 414. 5 F1B GPS Lat 34 34'N Lon135 34'E 12:34 · The acknowledgement is memorized into the RX memory channel. 30) RX < ACK received > J3E 7 After 5 sec. , starts distress call. TX 8. 414. 5 F1B GPS Lat 34 34'N Lon135 34'E 12:34 Exit Exit GPS Lat 34 34'N Lon135 34'E 12:34 t Activate an EPIRB (Emergency Position Indicating Radio Beacon) and prepare a SART (Search And Rescue Transponder) and VHF marine handheld transceiver before launching a survival craft. 17 7 CALL PROCEDURE D Regular distress call Transmit a distress call after selecting "Distress" in the DSC menu. NEVER USE THE DISTRESS CALL WHEN YOUR SHIP OR A PERSON IS NOT IN AN EMERGENCY. DISTRESS CALLS CAN BE USED ONLY WHEN IMMEDIATE HELP IS NEEDED. y Rotate [CH] to select the desired distress frequency, then push [ENT]. · After pushing [ENT], return to the DSC menu as shown in step e. ******* Distress ******* -------- Attempt ------ÇS i n g l e ; s i x f r e q u e n c y Single; 2187. 5kHz Single; 4207. 5kHz Single; 6312. 0kHz Single; 8414. 5kHz Single;12577. 0kHz Single;16804. 5kHz SEL OK q Push [DSC] to select DSC watch mode. w Push [MODE SET] to select the DSC menu. [CALL] [MODE SET] [ENT] [CANCEL] [F] [CH] [DSC] [FREQ/CH] e Rotate [CH] to select "Distress, " then push [ENT]. ******* DSC MENU ******* -------- Select -------Position Individual Group Geographical ÇD i s t r e s s Distress RLY Semi/Auto Test RX memory TX memory Set up Self test Exit SEL OK u Lift up the distress switch cover, push [DISTRESS] for 5 sec. to transmit the distress call. · The distress call is transmitted on the emergency frequency selected in step y. i After transmitting the call, the transceiver is set to the phone emergency frequency automatically. · The DSC receiver circuit is still working to receive an acknowledgement call on the previous frequency. · The distress call transmission and acknowledgement reception are performed on the all distress frequencies (2187. 5, 4207. 5, 6312. 0, 8414. 5, 12577. 0 and 16804. 5 kHz) in sequence when "Single;six frequency" is selected in step y. RX < Wait for ACK > r Rotate [CH] to select the desired nature then push [ENT]. ******* Distress ******* -------- Nature -------ÇU n d e s i g n a t e d Fire, Explosion Flooding Collision Grounding Capsizing Sinking Disable adrift Abandoning ship Piracy attack Man overboard SEL OK J3E GPS Lat 34 34'N Lon135 34'E 12:34 Exit o When receiving an acknowledgement, push any key to stop the alarm then reply to the connected station via the transceiver's handset or microphone. · The acknowledgement is memorized into the RX memory channel. 30) t Verify the position and UTC time data, then push [ENT]. · When no position and time data is applied to [GPS], your position and UTC time should be input in this step. ******* Distress ******* --- Position & time ---4 34. 343N Latitude Longitude 135 34. 343E 12:34 UTC Null OK 18 CALL PROCEDURE 7 D When no acknowledgement is received If no acknowledgement is received, the emergency alarm will sound continuously. [. . . ] of memory Ch. : · Antenna connector · Usable temp. range · Frequency stability : 1205 channels (max. ) 160 user programmable, 249 ITU SSB duplex, 124 ITU SSB simplex, 662 ITU FSK duplex and 10 Semi/Auto channels : SO-239×2 (50 ) : ­15°C to +55°C : ±10 Hz 30 dBµV emf (0. 5­1. 5999 MHz) 13 dBµV emf (1. 6­1. 7999 MHz) 8 dBµV emf (1. 8­29. 9999 MHz) J2B, F1B 13 dBµV emf (1. 6­1. 7999 MHz) 8 dBµV emf (1. 8­29. 9999 MHz) (20 dB SINAD) H3E 44 dBµV emf (0. 5­1. 5999 MHz) 30 dBµV emf (1. 6­1. 7999 MHz) (20 dB SINAD) 24 dBµV emf (1. 8­3. 9999 MHz) DSC receiver 0 dBµV emf (all channels) · Spurious response rejection ratio: Transceiver More than 70 dB (20 dB SINAD) (0. 5­29. 9999 MHz) J3E, A1A (Approx. after battery connection. ) · Power supply : 12 V DC version 10. 8­15. 6 V DC (floating ground) 24 V DC version 21. 6­31. 2 V DC (floating ground) · Current drain : 12 V DC version Transmit at max. audio Less than 6. 0 A 24 V DC version Transmit at max. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ICOM IC-M801E

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ICOM IC-M801E will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag