User manual ICOM IC-M802

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ICOM IC-M802. We hope that this ICOM IC-M802 user guide will be useful to you.

Lastmanuals help download the user guide ICOM IC-M802.


Mode d'emploi ICOM IC-M802
Download

You may also download the following manuals related to this product:

   ICOM IC-M802 BROCHURE (308 ko)
   ICOM IC-M802 INSTRUCTION MANUAL (2142 ko)

Manual abstract: user guide ICOM IC-M802

Detailed instructions for use are in the User's Guide.

[. . . ] INSTRUCTION MANUAL MF/HF MARINE TRANSCEIVER iM802 FOREWORD Thank you for purchasing this Icom product. The ICM802 MF/HF MARINE TRANSCEIVER is designed and built with Icom's superior technology and craftsmanship. With proper care, this product should provide you with years of trouble-free operation. We want to take a couple of moments of your time to thank you for making the IC-M802 your radio of choice, and hope you agree with Icom's philosophy of "technology first. " Many hours of research and development went into the design of your IC-M802. IMPORTANT READ THIS INSTRUCTION MANUAL CAREFULLY before attempting to operate the transceiver. SAVE THIS INSTRUCTION MANUAL. [. . . ] An urgency call is sometimes called a "PAN PAN call. " D Operation outline DSC menu ******* DSC MENU ******* -------- Select -------Position ÇI n d i v i d u a l Group All ships Position REQ Distress Test RX memory TX memory Set up Exit SEL OK Category selection ****** Individual ****** ------- Category ------Routine Safety ÇU r g e n c y Distress SEL OK Category selection ****** All ships ******* ------- Category ------Safety ÇU r g e n c y SEL OK Address ID selection ****** Individual ****** ------ Address ID -----ÇM a n u a l s e t 123456789 IC-M802-1 123456788 IC-M802-2 123456787 IC-M802-3 123456786 IC-M802-4 123456785 IC-M802-5 SEL OK Manual ID input ****** Individual ****** ------ Address ID -----987654321 1st telecommand selection ****** Individual ****** --- 1st telecommand ---ÇJ 3 E No information OK SEL OK Traffic frequency selection 1 ****** All ships ******* ****** Individual ****** -- Traffic frequency --ÇM a n u a l s e t T: 4567. 0kHz IC-M802-1 R: 4567. 0kHz T:12345. 0kHz IC-M802-2 R:12345. 0kHz SEL OK Traffic frequency selection 2 ****** All ships ******* ****** Individual ****** -- Traffic frequency --TX:_2134. 0kHz RX:_2134. 0kHz SEL OK Call frequency selection ****** All ships ******* ****** Individual ****** ---- Call frequency ---Ç 2187. 5kHz 4207. 5kHz 6312. 0kHz 8414. 5kHz 12577. 0kHz 16804. 5kHz SEL OK Confirmation screen ****** All ships ******* Push [CANCEL/CALL] for 1 sec. to store the condition into the TX memory channel. ****** Individual ****** --------- Call --------Category:Urgency To:987654321 Traffic:J3E TX 2134. 0kHz RX 2134. 0kHz 2187. 5kHz Call Freq:TX RX 2187. 5kHz Write-Menu Call 24 CALL PROCEDURE 7 D Urgency call operation q Push [MODE SET] to select the DSC menu. w Rotate [CH] to select either "Individual" or "All ships" then push [ENT]. · When selecting "All ships" e Rotate [CH] to select "Urgency, " then push [ENT]. ****** All ships ******* ------- Category ------Safety ÇU r g e n c y u After the calling stand-by screen appears, push and hold [CANCEL/CALL] for 1 sec. to transmit the urgency call. · The transceiver is set to the traffic frequency after the call transmission. to store the calling condition into the TX memory described in pages 23 and 43, if desired. ****** All ships ******* --------- Call --------Category:Urgency Traffic:J3E TX 2134. 0kHz RX 2134. 0kHz 2187. 5kHz Call Freq:TX RX 2187. 5kHz Write-Menu Call SEL OK r Rotate [CH] to select a traffic frequency from one of the pre-programmed frequencies or "Manual set" then push [ENT]. When a pre-programmed frequency is selected, go to step y. ****** All ships ******* -- Traffic frequency --ÇM a n u a l s e t T: 4567. 0kHz IC-M802-1 R: 4567. 0kHz T:12345. 0kHz IC-M802-2 R:12345. 0kHz SEL OK i Announce the following message. · "PAN PAN" · "All stations" (repeated 3 times). (your ship name). " · The 9-digit identity AND the call sign (or other identification of the ship) · The text of the urgency message. t Enter the desired traffic frequencies for both the transmit and receive, then push [ENT]. ****** All ships ******* -- Traffic frequency --TX:_2134. 0kHz RX:_2134. 0kHz SEL OK 7 y Rotate [CH] to select the desired calling channel, then push [ENT]. ****** All ships ******* ---- Call frequency ---Ç 2187. 5kHz 4207. 5kHz 6312. 0kHz 8414. 5kHz 12577. 0kHz 16804. 5kHz SEL OK 25 7 CALL PROCEDURE · When selecting "Individual" e Select "Urgency" as the category using [CH], then push [ENT]. ****** Individual ****** ------- Category ------Routine Safety ÇU r g e n c y Distress SEL OK u Enter the desired transmit and receive traffic frequency via the keypad, then push [ENT]. ****** Individual ****** -- Traffic frequency --TX:_2134. 0kHz RX:_2134. 0kHz SEL OK r Select (or enter) the 9-digit ID code, then push [ENT]. · Use [CH] to select the ID code when the desired ship's ID is pre-programmed. ****** Individual ****** ------ Address ID -----ÇM a n u a l s e t 123456789 IC-M802-1 123456788 IC-M802-2 123456787 IC-M802-3 123456786 IC-M802-4 123456785 IC-M802-5 SEL OK i Rotate [CH] to select the desired calling frequency, then push [ENT]. ****** Individual ****** ---- Call frequency ---Ç 2187. 5kHz 4207. 5kHz 6312. 0kHz 8414. 5kHz 12577. 0kHz 16804. 5kHz SEL OK · Select "Manual set" with [CH] then push [ENT], after that, enter the desired 9-digit ID via the keypad. ****** Individual ****** ------ Address ID -----987654321 o The calling stand-by screen is displayed as follows, verify the calling condition then push and hold [CANCEL/CALL] for 1 sec. to transmit the call. · Push and hold [ENT] for 1 sec. to store the calling condition into the TX memory described in pages 23 and 43, if desired. ****** Individual ****** --------- Call --------Category:Urgency To:987654321 Traffic:J3E TX 2134. 0kHz RX 2134. 0kHz 2187. 5kHz Call Freq:TX RX 2187. 5kHz Write-Menu Call OK t Rotate [CH] to select 1st telecommand, then push [ENT]. When "No information" is selected, go to step i. ****** Individual ****** --- 1st telecommand ---ÇJ 3 E No information !0 After sending the call, the transceiver waits for an acknowledgement. RX Individual < Wait for ACK > J2B SP GPS Lat 34 34'N Lon135 34'E 12:34 SEL OK Exit y Rotate [CH] to select the desired pre-programmed traffic frequency, or "Manual set" then push [ENT]. When pre-programmed traffic frequency is selected, go to step i. ****** Individual ****** -- Traffic frequency --ÇM a n u a l s e t T: 4567. 0kHz IC-M802-1 R: 4567. 0kHz T:12345. 0kHz IC-M802-2 R:12345. 0kHz SEL OK 26 CALL PROCEDURE 7 !1 When receiving an acknowledgement, the display shows the received ID code, or the called station name. · Push [FREQ/CH]; - to select the traffic frequency if the called station is able to comply to the call. - to return to DSC watch mode when unable. ************************ Individual ACK * * IC-M802 * * Able to comply * * ************************ Exit ************************ Individual ACK * * IC-M802 * * Unable to comply * * * Operator unavailable * ************************ Exit When the called station is unable to comply to the call, the reason may be displayed. !2 Announce the following message to the connected station. · "PAN PAN" · Desired station name (repeated 3 times). (your ship name). " · The 9-digit identity AND the call sign (or other identification of the ship) · The text of the urgency message. 7 27 7 CALL PROCEDURE I Safety call When you want to send a safety message to other ships, use "Safety" as the category. A safety call is sometimes called a "SECURITE call. " D Operation outline DSC menu ******* DSC MENU ******* -------- Select -------Position ÇI n d i v i d u a l Group All ships Position REQ Distress Test RX memory TX memory Set up Exit SEL OK Category selection ****** Individual ****** ------- Category ------Routine ÇS a f e t y Urgency Distress SEL OK Category selection ****** All ships ******* ------- Category ------ÇS a f e t y Urgency SEL OK Address ID selection ****** Individual ****** ------ Address ID -----ÇM a n u a l s e t 123456789 IC-M802-1 123456788 IC-M802-2 IC-M802-3 123456787 123456786 IC-M802-4 123456785 IC-M802-5 SEL OK Manual ID input ****** Individual ****** ------ Address ID -----987654321 1st telecommand selection ****** Individual ****** --- 1st telecommand ---ÇJ 3 E No information OK SEL OK Traffic frequency selection 1 ****** All ships ******* ****** Individual ****** -- Traffic frequency --ÇM a n u a l s e t T: 4567. 0kHz IC-M802-1 R: 4567. 0kHz T:12345. 0kHz IC-M802-2 R:12345. 0kHz SEL OK Traffic frequency selection 2 ****** All ships ******* ****** Individual ****** -- Traffic frequency --TX:_2134. 0kHz RX:_2134. 0kHz SEL OK Traffic frequency selection 3 ****** All ships ******* ****** Individual ****** ---- Call frequency ---Ç 2187. 5kHz 4207. 5kHz 6312. 0kHz 8414. 5kHz 12577. 0kHz 16804. 5kHz SEL OK Confirmation screen ****** All ships ******* Push [CANCEL/CALL] for 1 sec. to store the condition into the TX memory channel. ****** Individual ****** --------- Call --------Category:Safety To:987654321 Traffic:J3E TX 2134. 0kHz RX 2134. 0kHz 2187. 5kHz Call Freq:TX RX 2187. 5kHz Write-Menu Call 28 CALL PROCEDURE 7 D Safety call operation A safety call procedure is almost the same as the urgency call. q Push [MODE SET] to select the DSC menu. w Rotate [CH] to select the desired DSC format from "Individual" and "All ships, " then push [ENT]. · When selecting "All ships" e Rotate [CH] to select "Urgency, " then push [ENT]. ****** All ships ******* ------- Category ------ÇS a f e t y Urgency y Rotate [CH] to select the desired calling channel, then push [ENT]. ****** All ships ******* ---- Call frequency ---Ç 2187. 5kHz 4207. 5kHz 6312. 0kHz 8414. 5kHz 12577. 0kHz 16804. 5kHz SEL OK SEL OK r Rotate [CH] to select a traffic frequency from one of the pre-programmed frequencies or "Manual set" then push [ENT]. When a pre-programmed frequency is selected, go to step y. ****** All ships ******* -- Traffic frequency --ÇM a n u a l s e t T: 4567. 0kHz IC-M802-1 R: 4567. 0kHz T:12345. 0kHz IC-M802-2 R:12345. 0kHz SEL OK u After the calling stand-by screen appears, push and hold [CANCEL/CALL] for 1 sec. to transmit the safety call. · The transceiver is set to the traffic frequency after the call transmission. to store the calling condition into the TX memory described in pages 23 and 43, if desired. ****** All ships ******* --------- Call --------Category:Safety Traffic:J3E TX 2134. 0kHz RX 2134. 0kHz 2187. 5kHz Call Freq:TX RX 2187. 5kHz Write-Menu Call 7 t Enter the desired traffic frequencies for both the transmit and receive, then push [ENT]. ****** All ships ******* -- Traffic frequency --TX:_2134. 0kHz RX:_2134. 0kHz SEL OK i Announce the following message. · "SECURITE" (repeat 3 times) · "All stations" (repeated 3 times). [. . . ] The difference between a good and bad ground is easily noticed on transmission as well as reception. Since your ground counterpoise is actually a part of your complete antenna system, pay just as much attention to RF grounding as you did to putting up that white fiber glass whip or installing to your insulated backstay. 14 65 15 · General SPECIFICATIONS · Frequency coverage Receive Transmit : (Unit: MHz) · DSC channels · Type of emission Transceiver DSC receiver · No. of memory Ch. 0. 5­29. 9999 1. 6­2. 9999 4. 0­4. 9999 6. 0­6. 9999 8. 0­8. 9999 12. 0­13. 9999 16. 0­17. 9999 18. 0­19. 9999 22. 0­22. 9999 25. 0­27. 5000 : 2, 187. 5 kHz, 4, 207. 5 kHz, 6, 312. 0 kHz, 8, 414. 5 kHz, 12, 577. 0 kHz, 16, 804. 5 kHz : J3E (USB/LSB), H3E, * J2B (AFSK), F1B (FSK), A1A (CW) J2B *Receive only · Transmitter · Output power 1. 6­27. 5000 MHz · Spurious emission · Carrier suppression · Unwanted sideband suppression · Mic. connector : 150/60/20 W p­p : ­62 dB : 40 dB below peak output power : 55 dB below peak output power : 8-pin connector (2. 4 k) · Receiver · Sensitivity Transceiver : · Antenna connector · Usable temp. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ICOM IC-M802

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ICOM IC-M802 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag