User manual ICOM IC-V80E

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ICOM IC-V80E. We hope that this ICOM IC-V80E user guide will be useful to you.

Lastmanuals help download the user guide ICOM IC-V80E.


Mode d'emploi ICOM IC-V80E
Download

You may also download the following manuals related to this product:

   ICOM IC-V80E BROCHURE (271 ko)

Manual abstract: user guide ICOM IC-V80E

Detailed instructions for use are in the User's Guide.

[. . . ] INSTRUCTION MANUAL VHF TRANSCEIVER iV80 iV80E This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. WARNING: MODIFICATION OF THIS DEVICE TO RECEIVE C E L L U L A R R A D I OT E L E P H O N E S E RV I C E S I G N A L S I S PROHIBITED UNDER FCC RULES AND FEDERAL LAW. FOREWORD Thank you for purchasing this fine Icom product. The IC-V80/ V80E vhf transceiver is designed and build with Icom's superior technology and craftsmanship. [. . . ] For other transceivers While pushing [PTT], push and hold either the [] or [] for 1 or 2 sec. See page 36 for details. r Push [# ENT] to exit the Set mode. · Available subaudible tone frequencies 67. 0 69. 3 71. 9 74. 4 77. 0 79. 7 82. 5 85. 4 88. 5 91. 5 94. 8 97. 4 100. 0 103. 5 107. 2 110. 9 114. 8 118. 8 123. 0 127. 3 131. 8 136. 5 141. 3 146. 2 151. 4 156. 7 159. 8 162. 2 165. 5 167. 9 171. 3 173. 8 177. 3 179. 9 183. 5 186. 2 189. 9 192. 8 196. 6 199. 5 (unit: Hz) 203. 5 206. 5 210. 7 218. 1 225. 7 229. 1 233. 6 241. 8 250. 3 254. 1 CONVENIENT!Tone scan function: If you don't know the subaudible tone used for a repeater, the tone scan is convenient for detecting the tone frequency. Push [FUNC](M), and then [T. SCAN](3) to start a tone scan. · When the required tone frequency is detected, the scan pauses, and the tone frequency is temporarily set. · See page 34 for details of the tone scan function. 5 REPEATER OPERATION Lockout function The lockout function helps prevent interference to other stations by inhibiting transmitting when the channel is busy. The function can be set in the Initial Set mode. q While pushing and holding [] and [], turn the power ON to enter the Initial Set mode. w Push [] or [] to select the lockout item. (RLO) e Rotate [VOL] to select the lockout function option between OFF, repeater lockout, and busy lockout. · "RLO. OF" : Allows transmitting, even if signals are received. · "RLO. RP" : The repeater lockout function inhibits transmitting when the channel is busy, except while receiving a signal that includes a matched subaudible tone. · "RLO. bU" : The busy lockout function inhibits transmitting while receiving a signal. Auto repeater function U. S. A. version only The auto repeater function sets the standard repeater settings (duplex ON/OFF, duplex direction, tone encoder ON/OFF) when the operating frequency falls within or outside of the general repeater output frequency range. The offset and repeater tone frequencies are not changed by the auto repeater function. The function can be set in the Initial Set mode. q While pushing and holding [] and [], turn the power ON to enter the Initial Set mode. w Push [] or [] to select the auto repeater item. (RPt) e Rotate [VOL] to select a desired option. · "Rpt. OF" : Turns the function OFF. · "Rpt. R1" : The auto repeater function is activated for duplex only. · "Rpt. R2" : The auto repeater function is activated for duplex and tone encoder. r Push [# ENT] to exit the Initial Set mode. [VOL] The repeater lockout function is ON. r Push [# ENT] to exit the Initial Set mode. · Frequency range and offset direction Frequency range 145. 200 to 145. 495 MHz 146. 610 to 146. 995 MHz 147. 000 to 147. 395 MHz Duplex direction "­" appears. "+" appears. 23 MEMORY/CALL OPERATION General description The transceiver has 207 memory channels, including 6 scan edge memory channels (3 pairs), and 1 Call channel, for storage of often-used frequencies. 6 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 24 D Using the keypad q Push [VFO/MR/CALL] several times to select the memory mode. · "X" appears. D Memory channel contents The following information can be programmed into a memory channel: · Operating frequency (p. [. . . ] (default: VOX. 05) The VOX delay is set to 1 sec. The VOX delay is set to 3 sec. · VOX time-out timer The VOX function is turned OFF. The VOX gain is set to 10 (maximum). While speaking into the headset microphone, adjust the VOX gain until "On" continuously appears on the LCD. 53 Sets the VOX time-out timer to between 1, 2, 3, 4, 5, 10 and 15 min. to prevent accidental prolonged transmission for the VOX function. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ICOM IC-V80E

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ICOM IC-V80E will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag