User manual ICOM R9500

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

Sponsored Links

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ICOM R9500. We hope that this ICOM R9500 user guide will be useful to you.

Lastmanuals help download the user guide ICOM R9500.


ICOM R9500 : Download the complete user guide (19976 Ko)

Manual abstract: user guide ICOM R9500

Detailed instructions for use are in the User's Guide.

[. . . ] iR9500 Instruction Manual COMMUNICATIONS RECEIVER A-6553H-1EX Printed in Japan © 2007 Icom Inc. FOREWORD Thank you for making the IC-R9500 your radio of choice. We hope you agree with Icom's philosophy of "technology first. " Many hours of research and development went into the design of your IC-R9500. D FEATURES Ultimate receiver performance: 110 dB wide dynamic range and third-order intercept (IP3) of +40 dBm (HF bands only) 7-inch wide color TFT LCD Built-in Baudot FSK demodulator High resolution spectrum scope-- center frequency and fix frequency modes, plus mini-scope displays IMPORTANT READ THIS INSTRUCTION MANUAL CAREFULLY before attempting to operate the receiver. SAVE THIS INSTRUCTION MANUAL. This manual contains important safety and operating instructions for the IC-R9500. EXPLICIT DEFINITIONS WORD R WARNING CAUTION NOTE DEFINITION Personal injury, fire hazard or electric shock may occur. No risk of personal injury, fire or electric shock. TRADEMARKS Icom, Icom Inc. [. . . ] w Push [AGC VR/OFF] once or twice to select AGC volume (VR), then rotate [AGC] control to adjust the AGC time constant. · [AGC VR] indicator lights green and "VR" appears instead of "FAST, " "MID" or "SLOW. " D Setting the AGC time constant preset value q Select the desired mode (not FM/WFM or P25 mode). r Rotate the main dial to set the desired time constant for `AGC FAST. ' · AGC time constant can be set between 0. 1 to 8. 0 sec. to select a default value. · Selectable AGC time constant Mode FM WFM AM Default 0. 1 (FAST) 0. 1 (FAST) Fixed Fixed (unit: sec. ) Selectable AGC time constant 3. 0 (FAST) 0. 3, 0. 5, 0. 8, 1. 2, 1. 6, 2. 0, 2. 5, 3. 0, 5. 0 (MID) 4. 0, 5. 0, 6. 0, 7. 0, 8. 0 7. 0 (SLOW) 0. 3 (FAST) 0. 1, 0. 2, 0. 3, 0. 5, 0. 8, 1. 2, 1. 6, 2. 0, 2. 0 (MID) 2. 5, 3. 0, 4. 0, 5. 0, 6. 0 6. 0 (SLOW) 0. 1 (FAST) 0. 1, 0. 2, 0. 3, 0. 5, 0. 8, 1. 2, 1. 6, 2. 0, 0. 5 (MID) 2. 5, 3. 0, 4. 0, 5. 0, 6. 0 1. 2 (SLOW) 0. 1 (FAST) 0. 1, 0. 2, 0. 3, 0. 5, 0. 8, 1. 2, 1. 6, 2. 0, 0. 5 (MID) 2. 5, 3. 0, 4. 0, 5. 0, 6. 0 1. 2 (SLOW) 0. 1 (FAST) Fixed 5-10 t Push [AGC] to select medium time constant. y Rotate the main dial to set the desired time constant for `AGC MID. ' · AGC time constant can be set between 0. 1 to 8. 0 sec. to select a default value. SSB CW u Push [AGC] to select slow time constant. i Rotate the main dial to set the desired time constant for `AGC SLOW. ' · AGC time constant can be set between 0. 1 to 8. 0 sec. to select a default value. FSK P25 o Select another mode (not FM/WFM or P25). !0 Push [EXIT/SET] to exit the AGC set mode screen. RECEIVE FUNCTIONS 5 Twin PBT operation PBT (Passband Tuning) electronically narrows the IF passband width by shifting the IF frequency slightly outside of the IF filter passband, rejecting interference. Moving both [TWIN PBT] controls to the same position shifts the IF. [TWIN PBT] for lower [TWIN PBT] for higher The LCD shows the passband width and shift frequency graphically. Current passband width and shift frequency is displayed in the filter set screen. To set the [TWIN PBT] controls to the center positions, push and hold [PBT CLR] for 1 sec. The edge of the variable range is half of the passband width, and PBT is adjustable in 25 or 50 Hz steps. · [TWIN PBT] should normally be set to the center positions (PBT setting is cleared) when there is no interference. This comes from the DSP unit and does not indicate an equipment malfunction. [PBT CLEAR] Shows filter width, shifting value and condition · PBT operation example Both controls at center position (PBT1) (PBT2) Reducing a lower passband (PBT1) (PBT2) Reducing both higher and lower passbands (PBT1) (PBT2) or Passband Passband IF center frequency Interference Desired signal Interference Interference Desired signal 5-11 5 RECEIVE FUNCTIONS IF filter selection [FIL] The receiver has 3 passband width IF filters for each mode. For FM mode, the passband width is fixed and 3 passband widths are available. For AM mode, the passband width can be set within 200 Hz to 10 kHz in 200 Hz steps. For SSB and CW modes, the passband width can be set within 50 to 3600 Hz in 50 or 100 Hz steps. For FSK mode, the passband width can be set within 50 to 2700 Hz in 50 or 100 Hz steps. The PBT shift frequencies are automatically memorized for each filter. D IF filter selection q Select the desired mode. w Push [FILTER] several times to select the IF filter 1, 2 or 3. · The selected passband width and filter number is displayed in the LCD. D Filter passband width setting (except FM/WFM or P25 mode) q Push and hold [FILTER] for 1 sec. w Select any mode except FM/WFM or P25 mode. · Passband widths for FM modes are fixed and cannot be set. e Push [FILTER] several times to select the desired IF filter. r While pushing [F-1·BW], rotate the main dial to set the desired passband width. · In AM mode, the passband width can be set within the following range. 200 Hz to 10 kHz 200 Hz steps · In SSB and CW modes, the passband width can be set within the following range. [. . . ] If the IP address is duplicated, the network will crash. [F-5·OTHERS] [F-7·SET] q Push [EXIT/SET] several times to close a multifunction screen, if necessary. e Push [F-5·OTHERS] to select the others set mode. [F-1·Y] [F-2·Z] [F-3· ] [EXIT/SET] r Push [F-1·Y]/[F-2·Z] several times to select "IP Address. " t Push [F-3· ] to select the desired segment then rotate main dial to set the desired or specified IP address. · "192. 168. 0. 1" is the default setting. y Push [F-2·Z] to select "Subnet Mask" item. u Rotate main dial to set the desired or specified subnet mask. · "255. 255. 255. 0" is the default setting. i Push [POWER] to turn the receiver power OFF, then ON to accept the new IP address and subnet mask settings. 15-7 15 UPDATING THE FIRMWARE D Updating from the PC q Start up the IC-R9500 Firm Utility. iR9500 COMMUNICATIONS RECEIVER · The window as at left appears. w Read the caution in the window carefully. e Click [Yes] if you agree and to continue the firmware updating. Firm Utility ===CAUTION=== Updating the firmware is very risky. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ICOM R9500

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ICOM R9500 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag