If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual IDEAL 320 CONTRACTOR GRADE MULTIMETER. We hope that this IDEAL 320 CONTRACTOR GRADE MULTIMETER user guide will be useful to you.

Lastmanuals help download the user guide IDEAL 320 CONTRACTOR GRADE MULTIMETER.


Mode d'emploi IDEAL 320 CONTRACTOR GRADE MULTIMETER
Download
Manual abstract: user guide IDEAL 320 CONTRACTOR GRADE MULTIMETER

Detailed instructions for use are in the User's Guide.

[. . . ] Ensure meter is in proper working order before using. Performing a continuity check can verify proper operation. If the meter reading goes from overload to zero, this typically means the meter is in proper working order. Visually inspect leads for damage before using. [. . . ] from 1. 4 to 3 +3. 0% additional error for C. F. from 3 to 4 To Measure True RMS AC Voltage: 1. Plug the black test lead into the COM port and the red test lead into the Hz V µA port. Set the rotary switch to the ~ position. Connect the meter in parallel with the load or circuit. Measure AC Voltage. 6 DC Volts Circuit Connection: Range 600mV 6V 60V 600V 1000V Resolution 100µV 1mV 10mV 100mV 1V Max. Display 600. 0 ±(0. 5% reading 6. 000 + 2 digits) 60. 00 600. 0 1000 Accuracy Input Impedance: 10M (over 1000M in 600mV range) To Measure DC Voltage: 1. Plug the black test lead into the COM port and the red test lead into the Hz V µA port. Set the rotary switch to the v position. Connect the meter in parallel with the load or circuit. Measure DC Voltage 7 True RMS AC Current Circuit Connection: Range Resolution 60mA 600mA 10µA 100µA Accuracy +(1. 5% reading +5 Voltage Burden 2V max Max 60. 00 600. 0 AC Conversion Type: AC conversions are AC-coupled, true RMS responding, calibrated to the RMS value sine wave input. Overload Protection: A input: 1A (600V) fast blow fuse Crest Factor: +1. 5% additional error for C. F. from 1. 4 to 3 +3. 0% additional error for C. F. from 3 to 4 Frequency Response: 40 Hz ~ 500Hz To Measure True RMS AC Current: 1. Plug the black test lead into the COM port and the red test lead into the mA. Connect the meter in series with the load or circuit. 8 DC Current Circuit Connection: Range Resolution 600µA 6000µA 60mA 600mA 0. 1µA 1µA 10µA 100µA Voltage Max Burden < 4mV / µA 600. 0 ±(1. 0% reading 6. 000 + 2 digits) 2V max 60. 00 600. 0 Accuracy Overload Protection: A Input: (600V) fast blow fuse µA Input: 600V RMS To Measure DC Current: 1. Plug the black test lead into the COM port and the red test lead into the mA or Hz V µA port. Set the rotary switch to the mA or µA position. Connect the meter in series with the load or circuit. Measure DC Current. 9 Frequency/RPM Circuit Connection: Range 6000Hz 60KHz 600KHz 6MHz 60MHz Resolution 1Hz 10Hz 100Hz 1KHz 10KHz Sensitivity 100mV RMS Accuracy Frequency: 0. 01% ±1 digit 250mV RMS 1V RMS Overload Protection: 600V rms *Less than 20Hz the sensitivity is 1. 5V To Measure Frequency: 1. Plug the black test lead into the COM port and the red test lead into the Hz V µA port. [. . . ] Snap the jaw of the current clamp around one of the current carrying conductors. Additional Current Clamps: 200AAC 61-332 500 AAC 61-333 600 AAC/DC 61-334 1000 AAC 61-436 Flexible Clamp Adapters: 1000 AAC 61-330 3000 AAC 61-31 17 General Specifications LCD Display: Polarity Indication: 6000 count maximum reading Automatic, negative indicated, positive implied Overrange Indication: "OL" or "-OL" Low Battery Indication: " " when the battery voltage drops below operating voltage Size (WxHxD): 82mm x 164mm x 44mm (without holster) Sampling: 1 time/sec LCD Display, Auto Power Off: Approx. Operating Temperature: 0°C ~ 30°C (<80% RH), 30°C ~ 40°C (<75% RH), 40°C ~ 50°C (<45% RH) Storage Temperature: -20°C ~ 60°C (0~80% RH) when battery removed from meter Temperature Coefficient: 0. 15 x (specified accuracy) / °C, <18°C or >28°C Power Requirements: 9V NEDA 1604, 1EC bf 22, J1S 006P Battery Life: 300 hours (alkaline ) Installation Category: IEC 1010, 1000V Cat. II, 600V Cat III Environmental Conditions Indoor Use Maximum Altitude: 2000 Meter Installation Category: IEC 1010, 1000V Cat II, 600V Cat. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE IDEAL 320 CONTRACTOR GRADE MULTIMETER

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual IDEAL 320 CONTRACTOR GRADE MULTIMETER will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag