User manual IDEAL ND 5481-4 61-164 165

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual IDEAL ND 5481-4 61-164 165. We hope that this IDEAL ND 5481-4 61-164 165 user guide will be useful to you.

Lastmanuals help download the user guide IDEAL ND 5481-4 61-164 165.


Mode d'emploi IDEAL ND 5481-4 61-164 165
Download
Manual abstract: user guide IDEAL ND 5481-4 61-164 165

Detailed instructions for use are in the User's Guide.

[. . . ] ND 5481-4 61-164 165 Ins 11/21/06 1:28 PM Page 1 #61-165 #61-164 #61-165 The SureTest® w/AFCI, #61-165, also tests arc fault circuit interrupter (AFCI) devices to ensure that AFCI breakers protecting the circuit have been installed correctly. This test disrupts the electrical supply if a functional AFCI is present. This tool also checks for a shared neutral condition that leads to AFCI nuisance tripping. To maintain stated accuracies during repeated use, allow 20 seconds between insertions to adequately dissipate any heat buildup during the load testing. [. . . ] See the following equations for clarification. 6 Frequency 60HZ High/low frequency 5 ND 5481-4 61-164 165 Ins 11/21/06 1:28 PM Page 7 ASCC1 = Line Voltage (VHN)/ (Hot + Neu ) ASCC2 = Line Voltage (VHN)/ (Hot + 1/(1/Neu + 1/ Grd ) Impedance (Z) Measurements If the voltage drop measurement exceeds 5%, analyze the hot and neutral impedances. If one is significantly higher than the other, the problem is with the conductor with the much higher impedance. Then, check all connections on that conductor back to the panel. The actual current being leaked to ground is displayed. The TEST icon and hourglass symbol appear on the display to let the user know that the GFCI test is being performed. The GFCI device should trip within the UL established guideline causing the display to blank out with the loss of power. When the GFCI device is reset, the unit displays the actual trip time that the GFCI took to respond to the current imbalance and open the circuit. Pressing the down arrow button ( ) returns it to the wiring verification mode. If the GFCI fails to trip, the SureTest terminates the test after 6. 5 seconds. Further inspection should determine whether the GFCI circuitry is faulty, the GFCI is installed incorrectly, or if the circuit is protected by a GFCI device. UL Guideline for trip time: 20 1. 43 T=( I ) Where: T = seconds (s) I = milliamps (mA) Hot and Neutral Impedance High conductor impedance Notes: 1) In order to test a GFCI in a 2-wire system (no ground), the #61-175 ground continuity adapter must be used. Connect the alligator clip on the adapter to a ground source, such as to a metal, water or gas pipe. 2) All appliances or equipment on the ground circuit being tested should be unplugged to help avoid erroneous readings. In addition to performing a GFCI test for evaluating personal protection from shock hazards, the SureTest can also conduct testing to ensure equipment protection from ground faults exceeding 30mA. The method of operation is the same as the GFCI test noted in the first paragraph above but uses a different resistor to create a 30mA leakage current from hot-toground. To conduct an EPD test on an Equipment Protective Device, press the GFCI button to enter the GFCI main menu. The GFCI symbol in the display should be highlighted as the default test. Press the side arrow ( ) button to highlight the EPD symbol. Then, press the GFCI button to activate the test. The actual current being leaked to ground is displayed. The TEST icon and hourglass symbol appear on the display to let the user know that the 8 < 1 to protect people Ground Impedance <0. 25 to protect equipment Check code requirements and re-wire if necessary. Locate high resistance connection/device and repair/replace. 7 ND 5481-4 61-164 165 Ins 11/21/06 1:28 PM Page 9 EPD test is being performed. The EPD should trip causing the display to blank out with the loss of power. [. . . ] WARNING: The SureTest is designed for 120/240VAC circuits only. Do not exceed the rating of the SureTest with this adapter. This adapter also allows the operator to use the SureTest (#61-165 only) to verify AFCI protection on non-outlet based circuits in bedrooms, such as on circuits used for lighting, ceiling fans, and smoke detectors. #61-175 Ground Continuity Adapter This adapter allows the operator to verify that a cabinet or equipment chassis has been properly bonded to the system ground. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE IDEAL ND 5481-4 61-164 165

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual IDEAL ND 5481-4 61-164 165 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag