User manual IDEAL ND2353

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual IDEAL ND2353. We hope that this IDEAL ND2353 user guide will be useful to you.

Lastmanuals help download the user guide IDEAL ND2353.


Mode d'emploi IDEAL ND2353
Download
Manual abstract: user guide IDEAL ND2353

Detailed instructions for use are in the User's Guide.

[. . . ] Ensure meter is in proper working order before using. Performing a continuity check can verify proper operation. If the meter reading goes from overload to zero, this typically means the meter is in proper working order. Visually inspect leads for damage before using. [. . . ] Release the trigger and be sure that the jaws have closed completely. If the meter is in auto-ranging mode, the range will be automatically selected. If the meter is in manual ranging mode, press the range button to select the desired range. Measure AC current. 5 6 DC Current Measurements DC Current Range 400A 2000A 2000-2500A Overload Protection: Resolution 0. 1A 1A 1A + 3000A Accuracy ±(1. 5% +3) ±(2. 0% +3) 4. Release the trigger and be sure that the jaws have closed completely. If the meter is in auto-ranging mode, the range will be automatically selected. If the meter is in manual ranging mode, press the range button to select the desired range. Connecting to an Oscilloscope, Chart Recorder or Data Logger A 61-800 61-800 Power Cla mp OUTPUT 1mV /A HOLD 1200KW 2500A KW OFF KW 600V 2100A 250V Power Clamp HOLD OUTPUT 1mV/A 1200KW KW OFF 2500A 600V KW 2100A 250V V V A A °F V V A A °F True RM S True RMS DC A/W ZERO REL MIN MAX ® RANGE DC A/W ZERO REL MIN MAX ® RANGE CAT III - 600V CAT III - 600V To Measure DC Current Warning Make sure the test leads are disconnected prior to current measurements. Push and hold the DCA Zero button until the reading shows zero. Using the trigger to open the jaws, fully enclose the conductor within the clamp. 7 Current Range (AC, DC) 0-400A 400-2100A Overload Protection: 600VAC Output 1mV/A 1mV/A Accuracy ±(2. 5% +0. 5A) ±(2. 5% +5A) 8 To Connect to a Monitoring Device 1. The analog output of the meter is proportional to the current measurement (1mV/A). Connect the monitoring device to the input terminals of the power clamp meter. The red terminal is positive and the black terminal is negative . Connect these two terminals to an oscilloscope, chart recorder or data logger to observe the wave form, or record the data for future analysis. AC Voltage Measurements AC Voltage Resolution Accuracy Range (50/60Hz) Accuracy (40-1kHz) Input Impedance 5. If the meter is in manual ranging mode, press the range button to select the desired range. DC Voltage Measurements DC Voltage Resolution Accuracy Input Impedance Range 400mV 0. 1mV ±(1. 5% +3) 10M 4V 1mV 5M 40V 10mV 400V 100mV 600V 1V Overload Protection:800V 4V 40V 400V 600V 1mV 10mV 100mV 1V ±(1. 5% +5) ±(2. 0% +5) 5M Overload Protection: 800V TRMS Measurements on AC Range Accuracies specified at Crest Factor <3 To Measure AC Voltage 1. Insert the black test lead into the COM terminal and the red test lead into the + terminal. Connect the test probes in parallel with the load or circuit. If the meter is in auto-ranging mode, the range will be automatically selected. Insert the black test lead into the COM terminal and the red test lead into the + terminal. [. . . ] Replace the back case, and secure the case screws. 14 Lifetime Limited Warranty This meter is warranted to the original purchaser against defects in material or workmanship for the lifetime of the meter. During this warranty period, IDEAL INDUSTRIES, INC. will, at its option, replace or repair the defective unit, subject to verification of the defect or malfunction. This warranty does not apply to defects resulting from abuse, neglect, accident, unauthorized repair, alteration, or unreasonable use of the instrument. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE IDEAL ND2353

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual IDEAL ND2353 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag