User manual IDEAL ND2356

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual IDEAL ND2356. We hope that this IDEAL ND2356 user guide will be useful to you.

Lastmanuals help download the user guide IDEAL ND2356.


Mode d'emploi IDEAL ND2356
Download
Manual abstract: user guide IDEAL ND2356

Detailed instructions for use are in the User's Guide.

[. . . ] Test probe holder Use the single test probe holder to make voltage testing easy. Indicator lights (#61-701 and #61-702) HI-V High voltage indicator In any VAC/VDC range when a voltage greater than 30V is touched, the beeper will beep, and the red Hi-V LED will blink. In addition to the LED and beeper, the 61-702 will shake when connected to high voltage. Even if the LED can't be seen, or the beeper can't be heard the shake can be felt. [. . . ] Disconnect the meter from the circuit before turning off any inductor, including motors, transformers, and solenoids. Clean the exterior with clean dry cloth. General Operation Lead Storage Silicone test leads are provided with the meter. These test leads stay flexible in very cold weather and can withstand high temperatures without melting. For convenient lead storage, wrap the leads as shown. AC Current Auto power off To extend the life of your battery, the meter automatically turns off after approximately 60 minutes. Selecting Ranges For all ranges and functions choose a range just above the expected value. If display reads "OL" (overrange), select a higher range. If display shows less than three numbers, select a lower range for better resolution. Accuracy Specifications Accuracy specifications are based on nominal operating temperature of 74°F ±8°, and a relative humidity less than 75%. Accuracy is specified as ± (% of reading + number of least significant digits). Range Resolution Max Accuracy Models Display 200A 0. 1A 199. 9 ±(3%+5) 61-700, 61-701, 61-702 Frequency response: 50Hz - 60Hz; ±(5%+5) 60Hz - 400Hz. Set the rotary switch to the appropriate AAC range. With the jaws closed, separate one wire from a bundle using the long fixed jaw. Slide the wire to the corner where the two jaws meet, then open the jaws to let it in. Measure the current in only one wire at a time. AC & DC Volts DC Voltage Range Resolution 200mV 2000mV 20V 200V 600V 1000V 0. 1mV 1mV 10mV 0. 1V 1V 1V Max Display 199. 9 1999 19. 99 199. 9 600 1000 Accuracy Models ±(0. 5%+1) 61-700 ±(0. 5%+1) 61-700, 61-702 ±(0. 5%+1) 61-701 ±(0. 5%+1) 61-700, 61-702 ±(0. 5%+1) 61-700 ±(0. 5%+1) 61-702 To Measure Voltage: 5. Plug the black test lead into the COM port and the red test lead into the + port. Set the rotary switch to appropriate VAC or VDC range. Connect the meter in parallel with the load or circuit. Measure the voltage Frequency Max Accuracy Models Display 2000mV 1mV 1999 ±(1. 2%+3) 61-702 200V 0. 1V 199. 9 ±(1. 2%+3) 61-700, 61-701, 61-702 600V 1V 600 ±(2%+5) 61-700, 61-701 750V 1V 750 ±(2%+5) 61-702 Frequency response: 50Hz - 500Hz; ±(2%+5) 500Hz - 1KHz; 50Hz - 500Hz on 600V and 750V ranges. AC Voltage Range Resolution Range 2k~40kHz Resolution 1Hz Max Accuracy Display 40. 0 ±(0. 1%+3) Model 61-700, 61-701 7 8 Capacitance Testing To Measure Frequency: 1. Plug the black test lead into the COM port and the red test lead into the + port. Set the rotary switch to the HZ position. [. . . ] During this warranty period, IDEAL INDUSTRIES, INC. will, at its option, replace or repair the defective unit, subject to verification of the defect or malfunction. This warranty does not apply to defects resulting from abuse, neglect, accident, unauthorized repair, alteration, or unreasonable use of the instrument. Any implied warranties arising out of the sale of an IDEAL product, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited to the above. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE IDEAL ND2356

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual IDEAL ND2356 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag