User manual IDEAL ND2365

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual IDEAL ND2365. We hope that this IDEAL ND2365 user guide will be useful to you.

Lastmanuals help download the user guide IDEAL ND2365.


Mode d'emploi IDEAL ND2365
Download
Manual abstract: user guide IDEAL ND2365

Detailed instructions for use are in the User's Guide.

[. . . ] #61-481 Symbols in this Manual This symbol indicates where cautionary or other information is found in the manual. Fuse Battery Refer to Figure 1 and to the following numbered steps to familiarize yourself with the meter's front panel controls and connectors. 480 Platinum Pro Series Commercial Contractor Grade Multimeter 1 7 Hz Hz 9 10 8 2 True RMS True RMS 4 3 5 6 2 1. Digital Display ­ The digital display has 4000 counts LCD readout with 82 segments analog bar graph, auto polarity, decimal point, " " AC, DC RANGE, H APO and unit annunciators. Rotary Switch ­ Select the Function and Range desired. [. . . ] Plug the black test lead into the COM port and the red test lead into the VH port. Set the rotary switch to the V position. Push the blue button until AC is shown on the display. Connect the meter in parallel with the load or circuit. 6 5 DC Volts Circuit Connection: True RMS AC Current Circuit Connection: Hz Hz True RMS True RMS Range 400mV 4V 40V 400V 1000V Resolution 100µV 1mV 10mV 100mV 1V Max Display Accuracy 400. 0 ±(0. 25% +5) 4. 000 ±(0. 4% +1) 40. 00 ±(0. 25% +1) 400. 0 1000 Range 40mA 400mA 10A Resolution 10µA 0. 1mA 10mA Max Display 40. 00 400. 0 10. 00 Accuracy ±(2. 0% +5) ±(2. 5% +5) Voltage Burden 200mV max 2Vmax 2V max Input Impedance: 10M (over 1000M in 400mV range) To Measure DC Voltage: 1. Plug the black test lead into the COM port and the red test lead into the VHz port. Set the rotary switch to the V position. Push the blue button until DC is shown on the display. Connect the meter in parallel with the load or circuit. Measure DC Voltage. AC Conversion Type: AC conversions are ac-coupled, true rms responding, calibrated to the rms value Sine wave input. Overload Protection: 1A (500V) fast blow fuse for mA input 16A (500V) fast blow fuse for A input Crest Factor: +1. 5% additional error for C. F. from 1. 4 to 3 +3. 0% additional error for C. F. from 3 to 4 To Measure True RMS AC Current: 1. Plug the black test lead into the COM port and the red test lead into the mA or A port. Set the rotary switch to the mA or A position. Push the blue button until AC is shown on the display. Connect the meter in series with the load or circuit. 8 7 DC Current Circuit Connection: Frequency/RPM Circuit Connection: Hz Hz True RMS True RMS Range 40mA 400mA 10A Resolution 10µA 0. 1mA 10mA Max Accuracy Voltage Display Burden 40. 00 ±(0. 6% +2) 200mVmax 400. 0 ±(0. 7% +2) 2Vmax 10. 00 ±(1. 0% +2) 2V max Range 4. 0KHz/40KRPM 40KHz/400KRPM 400KHz/4MRPM 4MHz/40MRPM 40MHz/400MRPM Resolution 1Hz/300RPM 10Hz/300RPM 100Hz/3KRPM 1KHz/30KRPM 10KHz/300KRPM Sensitivity 100mV rms* Accuracy Frequency: 0. 01% ±1 digit RPM: 0. 01% ±10 digits Overload Protection: 1A (500V) fast blow fuse for A input 16A (500V) fast blow fuse for A input To Measure DC Current: 1. Plug the black test lead into the COM port and the red test lead into the mA or A port. Set the rotary switch to the mA or A position. Push the blue button until DC is shown on the display. Connect the meter in series with the load or circuit. [. . . ] Normally the forward voltage drop of a good silicone diode is shown between 400V and 90V. If the diode under test is defective, "000" (short circuit) or "OL" (non-conductive) is displayed. 15 Range 4nF 40nF 400nF 4µF 40µF 400µF 4mF 40mF Resolution 1pF 10pF 100pF 1nF 10nF 100nF 1µF 10µF Max Display 4. 000 40. 00 400. 0 4. 000 40. 00 400. 0 4. 000 40. 00 Accuracy ±(3. % reading +10 digits) ±(2% reading +8 digits) ±(5% reading +20 digits) Overload Protection: 600V rms To Measure Capacitance: 1. Plug the black test lead into the COM port and the red test lead into the VHz port. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE IDEAL ND2365

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual IDEAL ND2365 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag