User manual IDEAL ND2385

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual IDEAL ND2385. We hope that this IDEAL ND2385 user guide will be useful to you.

Lastmanuals help download the user guide IDEAL ND2385.


Mode d'emploi IDEAL ND2385
Download
Manual abstract: user guide IDEAL ND2385

Detailed instructions for use are in the User's Guide.

[. . . ] #61-492 1 490 Series Industrial Grade Multimeter ~Hz MIN/MAX 7 8 PEAK HOLD 10 14 13 9 12 11 2 3 Data Acquisition 4 ~Hz MIN/MAX PEAK HOLD 5 2 6 Data Acquisition 2 1. DO NOT UNDER ANY CIRCUMSTANCES EXCEED THESE RATINGS: - Voltage is not to exceed 1000 Volts. - Resistance, Capacitance, Logic and Continuity functions are not to be performed on circuits capable of delivering greater than 600 Volts. - Current measurements are not to be performed on circuits capable of delivering greater than 500 Volts 2. [. . . ] Push the blue button until AC is shown on the display. Connect the meter in series with the load or circuit. Frequency Response: 40Hz ~ 1kHz Overload Protection: 1A, 600V IR 10kA fuse for mA input 15A, 600V IR 100kA fuse for A input To Measure DC Current: 1. Plug the Black test lead into the COM port and the Red test lead into the mA or A port. Set the rotary switch to the mA or A position. Push the blue button until DC is shown on the display. Connect the meter in series with the load or circuit. Overload Protection: 1A, 600V IR 10kA fuse for mA input 15A, 600V IR 100kA fuse for A input 9 10 Frequency/RPM Circuit Connection: Resistance (Ohms) Circuit Connection: ~Hz MIN/MAX PEAK HOLD ~Hz MIN/MAX PEAK HOLD Data Acquisition Data Acquisition 2 2 Range 4kHz/40kRPM Resolution 1Hz/30RPM Max Display Sensitivity Accuracy 4. 000/40. 00 150mV 2. 0 Hz 1. 5V < 20 Hz Frequency: 0. 01% +1 RPM: 0. 01% + 10 40kHz/400kRPM 400kHz/4MRPM 4MHz/40MRPM 40MHz/400MRPM 10Hz/300RPM 100Hz/3KRPM 1kHz/30KRPM 40. 00/400. 0 400. 0/4. 000 4. 000/40. 00 300mV 1V *** Range 400 4k 40k 400k 4M 40M Resolution 0. 1 1 10 100 1K 10K Max Display 400. 0 4. 000 40. 00 400. 0 4. 000 40. 00 Accuracy ±(0. 7% +3) ±(0. 4% +2) ±(0. 6% +3) ±(1. 5% +5) 10kHz/300KRPM 40. 00/400. 0 400MHz/4000MRPM 100kHz/3MRPM 400. 0/4000 *This spec is not guaranteed. Plug the Black test lead into the COM port and the Red test lead into the VHz port. Set the rotary switch to the HZ RPM position. For RPM, Push the blue button until RPM is shown on the display. Connect the meter in parallel with the load or circuit. Overload Protection: 600V 11 To Measure Resistance: 1. Turn the power off to the circuit or device that is to be measured and discharge all capacitors before attempting a measurement. Plug the Black test lead into the COM port and the Red test lead into the VHz port. For correct reading, ensure that the device being tested contains no voltage. Press the range button to select the proper range of the meter. Overload Protection: 600V Open Circuit Voltage: -1. 3V (approx. ) 12 Capacitance Circuit Connection: Diode Testing Circuit Connection: ~Hz MIN/MAX PEAK HOLD ~Hz MIN/MAX PEAK HOLD Data Acquisition Data Acquisition 2 2 Range 4nF 40nF 400nF 4µF 40µF 400µF 4mF 40mF Resolution 1pF 10pF 100pF 1nF 10nF 100nF 1µF 10µF Max Display Accuracy 4. 000 +(3. 0% +10) 40. 00 +(3. 0% +5) 400. 0 4. 000 40. 00 400. 0 4. 000 +(5. 0% +20)* 40. 00 Function Resolution Accuracy Max. Open Current Circuit Voltage 1. 5mA 3V 1mV +(1. 5% +5) * For 0. 4V to 0. 8V. Turn off power to the device or circuit that is being tested and discharge all capacitors. Plug the Black test lead into the COM port and the Red test lead into the VHz port. Press the blue button until is shown on the display 5. [. . . ] Power Requirements: IEC LR03, AM4 or AAA size 1. 5V x 2. Dimensions (WxHxD): 90mmx200mmx42mm, with out holster 100mmx212mmx55mm, with holster Accessories: Protective Holster, battery (installed) instruction manual, test leads. C US Environmental Conditions Indoor use. Installation Category: IEC 1010, 1000V Cat. III Pollution Degree: 2 21 22 Maintenance Warning To avoid electrical shock, remove test lead before opening the cover. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE IDEAL ND2385

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual IDEAL ND2385 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag