User manual INFOSEC E 3

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual INFOSEC E 3. We hope that this INFOSEC E 3 user guide will be useful to you.

Lastmanuals help download the user guide INFOSEC E 3.


Mode d'emploi INFOSEC E 3
Download
Manual abstract: user guide INFOSEC E 3

Detailed instructions for use are in the User's Guide.

[. . . ] To ensure this product is correctly installed and properly used, we highly advise you to read this user guide very carefully. INTRODUCTION This series is a compact and totally pure sine wave interactive UPS, and is designed for critical applications and environments, such as desktops, servers, workstations, and other networking equipment. this model is available in 750 , 1000 , 1500 , 2000 , and 3000VA output ratings. This series protects your sensitive electronic equipment against power problems including power sags, spikes, brownouts, line noise, and blackouts. [. . . ] On the other hand, the LED indicator gives you a warning which will flash every two seconds when the battery is low. Line Mode LED: The line LED indicator comes on when the AC source is present. When the LED indicator is flashing, the UPS is either in AVR mode or off while AC power is active. Load Indicator: The show the load level. There are four LED bar indicators to show the percentage of UPS load capacity being used by the protected equipment. The greater the load, the more LED indicators illuminated. The higher the battery capacity, the more LED indicators illuminated. each LED indicator designates a 25% capacity level. Please see the following capacity level: 0 ~ 25%: 4th LED indicator rd th 26% ~ 50%: 3 and 4 LED indicators nd rd 51% ~ 75% 2 , 3 , and 4th LED indicators 76% ~ 100%: All four LED indicators will be on Indicator Condition Condition Utility Mode (AC Mode) Backup Mode (Power Failure) Alarm Line LED on Flashing every four seconds Site fault LED on (For 120VAC Models) Site Fault 4 segment LED bar: 0~25%: 4th LED on; 26~50%: 3rd and 4th LEDs on; 51~75%: 2nd, 3rd, and 4th LEDs on; 76~100%: all of 4 LEDs on Fault LED on Overload LED on Battery LED flashing every second Alarm Sounding every four seconds Sounding every second Sounding continuously Sounding every second Sounding every second 1 2 3 4 5 NEMA model (110/120/127Vac) IEC model (220/230/240Vac) UPS Rear Panel: The UPS rear panel pictures for IEC and NEMA models are shown as below: 1 2 3 4 5 6 7 8 9 AC Input N/A AC Output AC Input External Battery Connector NEMA model (110/120/127Vac) SNMP Port USB Port EPO Modem/Network Surge Protection Input Breaker IEC model (220/230/240Vac) Battery Pack Rear Panel: The battery pack rear panel pictures for IEC and NEMA models are shown below. NEMA model (110/120/127Vac) 1 2 3 4 5 6 IEC model (220/230/240Vac) 1 2 3 4 5 6 7 8 9 10 11 Modem/Network Surge Protection Input Breaker Input Power Cord SNMP Slot External Battery Connector EPO USB Port Function NEMA model (110/120/127Vac) IEC model (220/230/240Vac) If the UPS has been damaged during shipment, notify the carrier and dealer immediately 2. Position This UPS should be installed in a room with adequate airflow and free of contamination. Locate it in a clean and indoors environment, free from moisture, flammable liquids, and direct sunlight. Maintain a minimum clearance of 4 inches (100mm); the ambient temperature must be between 0°C and 40°C (32°F to 104°F), and relative humidity between 20% and 80% (non-condensing). CAUTION: The long term use at an ambient temperature in excess of 25°C would reduce battery life. In addition, place the UPS unit at least 20cm away from the monitor to avoid interference. Charging This UPS is shipped from the factory with its internal battery fully charged; however, some charge may be lost during shipping. the battery should be recharged prior to use. Plug the UPS into an appropriate power supply and allow the UPS to charge for at least 4 hours. Load Connection Connect one load-related device to each of the power receptacles supplied at the rear of the UPS. Modem/Phone line Connection Plug the incoming telephone line into the "In" socket at the back of the UPS. Use on telephone line cable and plug one end of the telephone line cable into the "Out" socket at the back of the UPS. Plug the other end into the modem input socket. [. . . ] Pull the battery out onto a flat surface. Slide the new battery into the battery pack. Put the front panel back on the battery pack. Remove the battery case front panel by pulling on both ends. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE INFOSEC E 3

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual INFOSEC E 3 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag