User manual INTELLISENSE FG-1025FD

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual INTELLISENSE FG-1025FD. We hope that this INTELLISENSE FG-1025FD user guide will be useful to you.

Lastmanuals help download the user guide INTELLISENSE FG-1025FD.


Mode d'emploi INTELLISENSE FG-1025FD
Download
Manual abstract: user guide INTELLISENSE FG-1025FD

Detailed instructions for use are in the User's Guide.

[. . . ] · Do not mount within 3 feet (0. 9 m) of forced air ducts, sirens, or bells measuring two inches (5 cm) or more in diameter. · Be sure to test the detector for detection in the final mounting location. MOUNTING PROCEDURE IMPORTANT NOTE: The FG-1025F detector flush mounts in a single gang box. The FG-1025FD detector flush mounts in a double gang box. (Gang box is not required; however, mounting directly in drywall is not recommended. ) The FG-1025FD detector is identical to the FG-1025F detector, except the faceplate and housing are doublewide. [. . . ] Jumper wire from C to TMPR STEP Figure 3 SWITCH LATCH FG-1025F/FD CONFIGURATION Configure DIP switch S1 to best suit the application. (See Figure 3. ) 3 LATCH LED = FACTORY DEFAULTS OFF Red alarm LED lights for 5 seconds when detector alarms LEDs are disabled except during power-up test ON Red alar m LED latches ON when detector alarms1, 2 LEDs are enabled LED 1 2 Latched alarm LED does not affect timing of alarm relay. Reset the alarm LED by removing and restoring power, or by toggling the S1 LATCH switch off and on. MOUNTING THE DETECTOR Mount the FG-1025F/FD detector as shown in Figure 4. For mounting the detector, #6 flathead (M 3. 5) screws are recommended. (Screws are not provided. ) STEP Figure 4 4 Terminal block Single gang box #6 (M 3. 5) screws (not provided) REPLACING THE FACEPLATE The faceplate has an effect on the sensitivity of the microphone. Be sure the faceplate is attached before testing the detector. (See Figure 5. ) Note: If required, the faceplate can be secured with a screw after installation. Break out the cover screw breakout flash, and secure the faceplate with a #4 (M 3) screw. (See Figure 4. ) Faceplate Optional knockout for faceplate screw PCB housing PCB cover LEDs DIP switch S1 Tamper arm IMPORTANT: Do not remove tamper arm from back of faceplate. Routed wires from terminal block STEP 5 #1 Figure 5 1. To replace the faceplate, hook the latches to the top of the detector first (#1). Then pivot the faceplate downward and snap the faceplate into place (#2). (See Figure 5. ) #2 2 TESTING The FG-1025F/FD should be tested at least once each year. Test the detector with the FG-701 Glassbreak Simulator. The model FG-700 Glassbreak Simulator can be used if it is set for the TEMPered glass sound. Other glassbreak simulators will not give accurate indication of range. You must place the FG-1025F/FD in Test Mode before you can test the detector. If you are using the FG-700, or if for any reason remote activation cannot be used, use a screwdriver to short the test pads on the PCB (see Figure 6). Once in test mode, the installer can test for range detection. Make sure to replace the faceplate of the FG1025F/FD before beginning testing. Stand within 10 feet (3 m) of the detector. Switch the FG-701 to ACTIVATE and MANual modes. Point the front of the simulator at the detector and press the red start button. [. . . ] If the trouble condition clears, the LEDs will return to the normal state. Always return the detector for repair if there is any indication of trouble, even if the trouble is temporary. POWER-UP SELF-TESTS · RAM Test: Write & read all RAM locations with one's & zero's · Arithmetic Test: Verify correct results for CPU arithmetic · Logic Test: Verify correct results for data comparisons · Clock Rate Test: Check clock frequency by measuring external time constants · Active Analog Circuit Test: Inject signals into analog channels to check gains, filters, A/D, and interrupts CONTINUOUS SELF-TESTS · Watchdog: Supervises microcontroller · ROM Checksum: Firmware ROM checksum verified · RAM Test: Write & read RAM locations with one's & zero's · Logic Test: Verify correct results for data comparisons · Passive Analog Circuit Test: Verify analog inputs are within normal bounds SPECIFICATIONS Range: 25' (7. 6 m) maximum No minimum range Alarm Relay: Form A, 125 mA maximum 25 VDC maximum Alarm Duration: 5 seconds (unaffected by alarm LED latching) Tamper Switch: Cover tamper 25 mA maximum 24 VDC maximum Power Requirements: 8 - 14 VDC; 25 mA typical at 12 VDC, 35 mA max AC Ripple: 4 Volts peak to peak at Nominal 12 VDC Operating Temperature: 32o to 120 o F (0o to 49o C) Storage: -4o to 122o F (-20o to 50 o C) RF Immunity: 30 V/m, 10 MHz - 1000 MHz ESD Immunity: 10 kV, Discharges of either polarity to exposed surfaces Dimensions: FG-1025F: Faceplate: 4. 49" x 2. 76" (114mm x 70mm), rear cover: 2. 65"H x 1. 97"W x 1. 85"D (67. 4mm x 50mm x 47mm) FG-1025FD: Faceplate: 4. 49" x 4. 49" (114mm x 114mm), rear cover: 2. 65"H x 1. 97"W x 1. 85"D (67. 4mm x 50mm x 47mm) Weight: FG-1025F: 3. 1 oz (87g), packed product: 4. 7 oz (133g) FG-1025FD: 3. 8 oz (107g), packed product: 6. 5 oz (184g) Accessories: FG-701 Glassbreak Simulator Approvals/Listings: FCC certified UL listed LED Indicators: The two LEDs on the front cover are used to indicate the detector's operational status. The following table summarizes the LED operation when the LEDs are enabled. Condition Green LED Red LED Normal, no event Normal, event detected Normal, break detected Power-up self-test Trouble detected Test mode, no alarm Test mode, event detected Test mode, alarm OFF Flicker OFF ON, one second Flash ON/OFF Flash once per second Flicker Flash once per second OFF OFF ON ON, one second Flash OFF/ON OFF OFF ON Protected Glass: Minimum size for all types is 11" (28 cm) square. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE INTELLISENSE FG-1025FD

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual INTELLISENSE FG-1025FD will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag