User manual INTERMATIC 158ET10367

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual INTERMATIC 158ET10367. We hope that this INTERMATIC 158ET10367 user guide will be useful to you.

Lastmanuals help download the user guide INTERMATIC 158ET10367.


Mode d'emploi INTERMATIC 158ET10367
Download
Manual abstract: user guide INTERMATIC 158ET10367

Detailed instructions for use are in the User's Guide.

[. . . ] 120-277 V. A. C. Description The Intermatic Electronic 24 Hour Time Switch automatically switches loads according to a preset daily schedule. This time switch is designed to directly switch loads up to 30 amps and to switch resistive or inductive loads up to the time switch rating. For use as a control timer in applications requiring 24 hour load control such as lighting, heating, air conditioning systems, pumps, etcetera. Up to eight set points or events (4 ON/4 OFF) can be preset. [. . . ] simply press in and downward (in the direction of the arrow) on the battery cover which is identified with the word "Battery". It is recommended that the battery be replaced with a "AA" industrial grade alkaline cell at two to three year intervals as part of the normal time switch maintenance observing battery polarity markings when installing. No other maintenance is required. Knockouts FIG. #2 NOTE: For 120 Volt loads only since the timer voltage is 120 VAC a jumper can be added between terminals 2 and 3 to supply load power. CAUTION: Do not use jumper if load(s) are not 120V. Supply separate power of the correct voltage to terminal 3. 8. Place the selector switches in the "MANUAL" and "RUN" positions. Reapply power to the time switch. Install Jumper Only If Timer Input and Load Voltage Are The Same, Otherwise provide a separate source of load power to terminal 3. FIG. Press the reset switch for three to five seconds. Refer to the chart below and enter the scheduled events (set points) required. EVENT On 1 Off 2 On 3 Off 4 On 5 Off 6 On 7 Off 8 TIME NOTE: For 120 Volt loads only since the timer voltage is 120 VAC a jumper can be added between terminals 2, 3 and 5 to supply load power. CAUTION: Do not use jumper if load(s) are not 120V. Supply separate power of the correct voltage to terminal 3 and 5. Neutral 120 VAC Hot Programming Steps Refer to programming instructions on time switch door label and note the following: · The MANUAL/AUTO selector can be used to temporarily override the program. Under normal operation the selector should be in the AUTO mode. The MANUAL mode maintains the program but prevents the loads from automatically switching. · The other selector switch is used to set the time of day (TIME SET), the program information (PROGRAM) or to run the program (RUN). FOR A PROGRAM TO FUNCTION PROPERLY, THE TWO SELECTOR SWITCHES MUST BE IN THE AUTO AND RUN POSITIONS. · The RESET switch is used only prior to initially programming the time switch or to erase all programmed set points. · By holding the hour and/or minute buttons depressed you can achieve a fast roll of the displayed time. This is useful when setting the time of day or setting the programmed set points (events). · Up to 4 ON and 4 OFF set points (8 events) can be programmed. · The load can manually be switched ON or OFF at any time only if the selector switch is in the RUN mode by pressing the ON/OFF button. [. . . ] The warranty does not apply to: (a) damage caused by accident, abuse, mishandling, dropping, acts of God, or any negligent use; (b) units which have been subject to unauthorized repair, opened, taken apart, or otherwise modified; (c) units not used in accordance with directions; (d) damages exceeding the cost of the product. Some states do not allow a limitation of damages, so the foregoing limitation may not apply to you. This warranty gives you specific legal rights and you may have other rights that vary from state to state. INTERMATIC INCORPORATED WILL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE INTERMATIC 158ET10367

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual INTERMATIC 158ET10367 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag