User manual JBSYSTEMS LIGHT ATLAS V 1.1

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual JBSYSTEMS LIGHT ATLAS. We hope that this JBSYSTEMS LIGHT ATLAS user guide will be useful to you.

Lastmanuals help download the user guide JBSYSTEMS LIGHT ATLAS.


Mode d'emploi JBSYSTEMS LIGHT ATLAS
Download

You may also download the following manuals related to this product:

   JBSYSTEMS LIGHT ATLAS V 1.2 (2511 ko)
   JBSYSTEMS LIGHT ATLAS V 2.0 (2218 ko)

Manual abstract: user guide JBSYSTEMS LIGHT ATLASV 1.1

Detailed instructions for use are in the User's Guide.

[. . . ] uses LEDs with extremely long lifespan!Virtually no heat production Very low power consumption Lightweight (no lamp transformers needed) 0-100% dimming and ultra fast strobe function Excellent built-in programs for wonderful, ever changing, light shows: DMX-control: 4 channels Standalone: sound activated with internal mic Master/slave: wonderful synchronized shows Optional CA-8 remote controller available Equipped with big optical lens for maximum light output The lightning flash with arrowhead symbol within the equilateral triangle is intended to alert the use or the presence of un-insulated "dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock. The exclamation point within the equilateral triangle is intended to alert the user to the presence of important operation and maintenance (servicing) instructions in the literature accompanying this appliance. This symbol means: indoor use only This symbol means: Read instructions To protect the environment, please try to recycle the packing material as much as possible. [. . . ] Should there be any, do not use the device and consult your dealer first. Important: This device left our factory in perfect condition and well packaged. It is absolutely necessary for the user to strictly follow the safety instructions and warnings in this user manual. Any damage caused by mishandling is not subject to warranty. The dealer will not accept responsibility for any resulting defects or problems caused by disregarding this user manual. Keep this booklet in a safe place for future consultation. If you sell the fixture, be sure to add this user manual. This input receives instructions from a DMX-controller or from another unit when used in master/slave mode. DMX output: 3pin female XLR-connector used to connect the Atlas with the next unit in the DMX chain or with another Atlas when used in master/slave mode. Hanging bracket with 1 knob to fasten the unit and a mounting hole to fix a mounting hook. DIP switches, used to set the DMX-starting address of the unit. To prevent strange behavior of the light effects, due to interferences, you must use a 90 to 120 terminator at the end of the chain. Never use Y-splitter cables, this simply won't work!Make sure that all units are connected to the mains. Each light effect in the chain needs to have its proper starting address so it knows which commands from the controller it has to decode. In the next section you will learn how to set the DMX addresses. How to set the DIP-switches to obtain the right starting address: Each of the first 9 DIP-switches correspond to a certain DMX-value: DIP #1 #2 #3 #4 #5 #6 #7 #8 #9 Value 1 2 4 8 16 32 64 128 256 Important: The installation must be carried out by qualified service personal only. Improper installation can result in serious injuries and/or damage to property. overhead rigging requires extensive experience!Working load limits should be respected, certified installation materials should be used, the installed device should be inspected regularly for safety. Make sure the area below the installation place is free from unwanted persons during rigging, de-rigging and servicing. Locate the fixture in a well ventilated spot, far away from any flammable materials and/or liquids. [. . . ] The mains cables must be in impeccable condition and should be replaced immediately when even a small problem is detected. In order to protect the device from overheat the cooling fans (if any) and ventilation openings should be cleaned monthly. The interior of the device should be cleaned annually using a vacuum cleaner or air-jet. The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to optimize light output. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE JBSYSTEMS LIGHT ATLAS

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual JBSYSTEMS LIGHT ATLAS will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag