User manual JBSYSTEMS LIGHT DX-1220

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual JBSYSTEMS LIGHT DX-1220. We hope that this JBSYSTEMS LIGHT DX-1220 user guide will be useful to you.

Lastmanuals help download the user guide JBSYSTEMS LIGHT DX-1220.


Mode d'emploi JBSYSTEMS LIGHT DX-1220
Download
Manual abstract: user guide JBSYSTEMS LIGHT DX-1220

Detailed instructions for use are in the User's Guide.

[. . . ] DX-1220 is normally settled in a rack, so the rack must be airy. If not, the inner will be overheat and then DX-1220 will shut down or can't operate correctly. Maximum output of individual channel is 25A For the moments testing. ( about 10 minutes. ) Output of individual channel 20A : For many hours . [. . . ] LOAD: 20A MAX output per channel DMX signal ( 5 pin XLR) DMX512 / 1990 DMX signal input channel512 channels DMX signal input connectorXLR 5-pin Analog signal input valtage: 0-10V DC Analog signal input channel (D TYPE 15pin)12 channels Analog signal connectorD TYPE connector 15 PIN Dimension: 19" 4U482(L) x 176(H) x 260(D)mm Weight: 20. 5 KG 4 Lite-Puter ISO 9001 CERTIFIED Chapter 2. 2-1 Installation and function introduction Installation DX-1220 is composed of 12 sets "P-27" ( one channel module ) and 1 set of "DP-5" ( DMX interface ). The modular design is for easy to replace, repair and change update software fast. Front panel P-27 PACK P-27 PACK P-27 PACK P-27 PACK P-27 PACK P-27 PACK P-27 PACK P-27 PACK P-27 PACK P-27 PACK P-27 PACK P-27 PACK AC TRIG AC TRIG AC TRIG AC TRIG AC TRIG AC TRIG AC TRIG AC TRIG AC TRIG AC TRIG AC TRIG AC TRIG V1 V2 V3 DMX FIRST CH. CAN SEL SET FNC MODE 0-10VDC ANALOG IN PUSH DMX OUT DMX IN ON TERMINATE 2-2 The main function of P-27 P-27 (One Channel Driver Module) P-27 PACK AC TRIG 5 Lite-Puter ISO 9001 CERTIFIED P-27 1. Unlock / lock knob: pull-unlock, push-lock. 25A magnetic circuit breaker P-27 PACK AC TRIG 5. Ventilator Specifications: AC input : 100 --- 240VAC AC output : 20A MAX Control input : 4 --- 12VDC Dimension : 30 * 176 * 192 mm ( W * H * D ) Weight : 0. 92 Kg 2-3 Introduction of DP-5 V1 V2 V3 DMX CAN SEL SET FNC MODE DMX OUT DMX IN ( 6) Phase input indicators ( 7) DMX signal input indicator ( 8) LED display ( 9) wbutton (10) 5button (11) 4button (12) CANCEL button (13) SEL / select button (14) 6button (15) SET/ setting button (16) FUN / function button (17) MODE button (18) 5 PIN DMX "OUT" connector (19) 5 PIN DMX "IN" connector (20) 0-10VDC connector (21) Terminate switch (22) Unlock / lock knob: pull-unlock push-lock 6 Lite-Puter ISO 9001 CERTIFIED 2- 4 Connection of DMX & ANALOG The DP-5 is photo isolated from DMX signal input; data transfer is done by photo coupler. CAUTION: For using 5 pin XLR plug, do not connect PIN 1 to the housing of the plug. DMX Connection XLR 5pin PIN 1: GND PIN 2: DATA PIN 3: DATA + PIN 4: NC PIN 5: NC Analog Connection D-type 15pin PIN 1: CH-1 PIN 2: CH-2 PIN 3: CH-3 PIN 12: CH-12 PIN 13: NC PIN 14: DC OUTPUT +12V / 100mA PIN 15: GND Analog Connector 2-5 FOR 3 PHASE 4 WIRES E GND N N V1 V1(100A max) V2 V2(100A max) V2' V3 V3(100A max) REAL PANEL FOR 1 PHASE 3 WIRES E GND N N V1 V(100A max) V2 V2' V'(100A max) V3 N 12 E N 11 N 10 E N 9 N 8 E N 7 N 6 E N 5 N 4 E N 3 N 2 E N 1 E E N N LOAD CH12 E LOAD CH11 LOAD CH10 E LOAD CH9 LOAD CH8 E LOAD CH7 LOAD CH6 E LOAD CH5 LOAD CH4 E LOAD CH3 LOAD CH2 E LOAD CH1 V1 V2 V1 V2 V2' V2' V3 V3 23 24 25 (23) AC Main power input terminal 3 phases 4wires. 150A for each connecting point) (24) Temperature controlled fans. 30A for each connecting point) 7 Lite-Puter ISO 9001 CERTIFIED Chapter 3. MODE Press "MODE" key , DX-1220 will offer 3 operation modes: "DMX" , "ANALOG" and "OFF" mode. 3-1 DMX mode In the DMX mode, DX-1220 will accept DMX-512 dimming signal input also analog 0 --10VDC signal. Press "MODE" key to choose DMX mode, the LED will display the selected address of DMX as follows, and then press "SEL" key to confirm. 3-2 ANALOG mode In the ANALOG mode, DX-1220 will only accept ANALOG signal input. Press "MODE" key to choose ANALOG mode, the LED will display as follows, and then press "SEL" to confirm. 3-3 OFF mode In the OFF mode, DX-1220 will not accept any signal. Press "MODE" key to choose OFF mode, the LED will be display as follows, and then press "SEL" to confirm. When system is turned on, memory resets to last selected mode prior to turning off. For example, if "OFF" mode was selected, then "OFF" mode continues when system is turned on. 8 Lite-Puter ISO 9001 CERTIFIED 3-4 How to set the start address of channels Operation: Press "MODE" key to choice DMX mode, and then press the assist key to confirm the correct start address of DMX channels. Assist key: Press 4: Increase channel eg: Led display from d 0 0 1 to d 0 0 2. Press w: Decrease channel eg: Led display from d 0 0 2 to d 0 0 1. eg: Led display from d 0 0 1 to d 0 1 3. PressSEL: Select / Confirmation key. PS: (1) In the DMX mode, total 512 channels can be set start address by users. (Each DX-1220 has 12 channels output. ) Eg. : If start address is set d 0 0 1 by users, and DX-1220 has DMX 1st channel ------ 12th channel . Eg. : If start address is set d 0 1 3 by users, and DX-1220 has DMX 13th channel ------ 24th channel . PressCAN: Function over and restore to last confirmed mode. When a channel is set as non-dimming function, it will light when the percent of this channel light over 51%. 4-4 Display the Voltage (Only display the Voltage of V3) Displays the current AC voltage and will change to 200 - 240VAC automatically if the AC input is 230VAC. 4-5 Display internal temperature Internal temperature displayed to prevent from overheat and to control the operation of fans. (1) To avoid inhaling dust. When the internal temperature is over 37, the fans start to work 1 minute and stop 1 minute in turn. (2) When the internal temperature is over 41, the fans turn continuously . [. . . ] PressSEL: Select / Confirmation key. 17 Lite-Puter ISO 9001 CERTIFIED 5-5 The corresponding list of setting fader time(from 00 --- to FL) set 50Hz 60Hz set 50Hz 60Hz set 50Hz 60Hz set 50Hz 60Hz set 50Hz 60Hz set 50Hz 60Hz set 50Hz 60Hz set 50Hz 60Hz 00 01 02 03 04 05 06 07 08 09 NoFade NoFade 20 01'22 01'24 01'27 01'29 01'32 01'34 01'37 01'39 01'42 01'45 01'08 01'10 01'12 01'14 01'17 01'19 01'21 01'23 01'25 01'27 01'29 01'31 01'34 01'36 01'38 01'40 01'42 01'44 01'46 01'48 01'51 01'53 01'55 01'57 01'59 02'01 02'03 02'05 02'08 02'10 02'12 02'14 40 41 42 43 44 45 46 47 48 49 02'43 02'46 02'48 02'51 02'53 02'56 02'59 03'01 03'04 03'06 02'16 02'18 02'20 02'22 02'25 02'27 02'29 02'31 02'33 02'35 02'37 02'39 02'42 02'44 02'46 02'48 02'50 02'52 02'54 02'56 02'59 03'01 03'03 03'05 03'07 03'09 03'11 03'13 03'16 03'18 03'20 03'22 60 61 62 63 64 65 66 67 68 69 04'05 04'07 04'10 04'12 04'15 04'18 04'20 04'23 04'25 04'28 03'24 03'26 03'28 03'30 03'33 03'35 03'37 03'39 03'41 03'43 03'45 03'47 03'50 03'52 03'54 03'56 03'58 04'00 04'02 04'04 04'07 04'09 04'11 04'13 04'15 04'17 04'19 04'21 04'24 04'26 04'28 04'30 80 81 82 83 84 85 86 87 88 89 05'37 05'49 06'02 06'15 06'28 06'40 06'53 07'06 07'19 07'31 04'41 04'51 05'02 05'12 05'23 05'34 05'44 05'55 06'06 06'16 06'27 06'37 06'48 06'59 07'09 07'20 07'31 07'41 07'52 08'02 08'13 08'24 08'34 08'45 08'56 09'06 09'17 09'27 09'38 09'49 09'59 10'10 A0 12'25 A1 12'37 A2 12'50 A3 13'03 A4 13'16 A5 13'28 A6 13'41 A7 13'54 A8 14'07 A9 14'19 AA 14'32 AB 14'45 AC 14'58 AD 15'10 AE 15'23 AF 15'36 B0 15'49 B1 16'01 B2 16'14 B3 16'27 B4 16'40 B5 16'52 B6 17'05 B7 17'18 B8 17'31 B9 17'43 BA 17'56 BB 18'09 BC 18'22 BD 18'34 BE 18'47 BF 19'00 10'21 10'31 10'42 10'52 11'03 11'14 11'24 11'35 11'46 11'56 12'07 12'17 12'28 12'39 12'49 13'00 13'11 13'21 13'32 13'42 13'53 14'04 14'14 14'25 14'36 14'46 14'57 15'07 15'18 15'29 15'39 15'50 C0 19'13 C1 19'25 C2 19'38 C3 19'51 C4 20'04 C5 20'16 C6 20'29 C7 20'42 C8 20'55 C9 21'07 CA 21'20 CB 21'33 CC 21'46 CD 21'58 CE 22'11 CF 22'24 D0 22'37 D1 22'49 D2 23'02 D3 23'15 D4 23'28 D5 23'40 D6 23'53 D7 24'06 D8 24'19 D9 24'31 DA 24'44 DB 24'57 DC 25'10 DD 25'22 DE 25'35 DF 25'48 16'01 16'11 16'22 16'32 16'43 16'54 17'04 17'15 17'26 17'36 17'47 17'57 18'08 18'19 18'29 18'40 18'51 19'01 19'12 19'22 19'33 19'44 19'54 20'05 20'16 20'26 20'37 20'47 20'58 21'09 21'19 21'30 E0 E1 E2 E3 E4 E5 E6 E7 E8 E9 26'01 26'13 26'26 26'39 26'52 27'04 27'17 27'30 27'43 27'55 21'41 21'51 22'02 22'12 22'23 22'34 22'44 22'55 23'06 23'16 23'27 23'37 23'48 23'59 24'09 24'20 24'31 24'41 24'52 25'02 25'13 25'24 25'34 25'45 25'56 26'06 26'17 26'27 26'38 26'49 26'59 27'10 00'03 00'05 00'08 00'10 00'13 00'15 00'18 00'20 00'23 00'02 00'04 00'06 00'09 00'11 00'13 00'15 00'17 00'19 00'21 00'23 00'26 00'28 00'30 00'32 00'34 00'36 00'38 00'40 00'43 00'45 00'47 00'49 00'51 00'53 00'55 00'57 01'00 01'02 01'04 01'06 21 22 23 24 25 26 27 28 29 0A 00'26 0B 00'28 0C 00'31 0D 00'33 0E 0F 10 11 12 13 14 15 16 17 18 19 00'36 00'38 00'41 00'43 00'46 00'48 00'51 00'54 00'56 00'59 01'01 01'04 2A 01'47 2B 01'50 2C 01'52 2D 01'55 2E 2F 30 31 32 33 34 35 36 37 38 39 01'57 02'00 02'02 02'05 02'08 02'10 02'13 02'15 02'18 02'20 02'23 02'25 4A 03'09 4B 03'11 4C 03'14 4D 03'16 4E 4F 50 51 52 53 54 55 56 57 58 59 03'19 03'21 03'24 03'27 03'29 03'32 03'34 03'37 03'39 03'42 03'44 03'47 6A 04'30 6B 04'33 6C 04'35 6D 04'38 6E 6F 70 71 72 73 74 75 76 77 78 79 04'41 04'43 04'46 04'48 04'51 04'53 04'56 04'58 05'01 05'03 05'06 05'09 8A 07'44 8B 07'57 8C 08'10 8D 08'22 8E 8F 90 91 92 93 94 95 96 97 98 99 08'35 08'48 09'01 09'13 09'26 09'39 09'52 10'04 10'17 10'30 10'43 10'55 EA 28'08 EB 28'21 EC 28'34 ED 28'46 EE 28'59 EF 29'12 F0 F1 F2 F3 F4 F5 F6 F7 F8 F9 29'25 29'37 29'50 30'03 30'16 30'28 30'41 30'54 31'07 31'19 1A 01'06 1B 01'09 1C 01'11 1D 01'14 1E F 01'17 01'19 3A 02'28 3B 02'30 3C 02'33 3D 02'36 3E 3F 02'38 02'41 5A 03'50 5B 03'52 5C 03'55 5D 03'57 5E 5F 04'00 04'02 7A 05'11 7B 05'14 7C 05'16 7D 05'19 7E 7F 05'21 05'24 9A 11'08 9B 11'21 9C 11'34 9D 11'46 9E 9F 11'59 12'12 FA 31'32 FB 31'45 FC 31'58 FD 32'10 FE 32'23 FF 32'36 18 Lite-Puter ISO 9001 CERTIFIED 5-6 Set "square law " or " linear" dimming curve Square law dimming curve:C2 It can react the linear relationship between dimming scale and output waltage, so it would be easy to evaluate the precision of the output waltage. Linear dimming curve:C3 This is suited for the stage lighting. The output voltage value and the controlling value are in linear ratio, and it enables a wider control range in low brightness, so the professional lighting designers prefer to this. Indicator key : Press 5: Change dimming curve Press 6: Change dimming curve PressSEL: Select / Confirmation key NOTEOriginal setting is C3. 100% The human eyes are most sensitive to the light brightness range, which is under 25% of the 100% brightness, so the use of curve C3 enables a wider control range. LIGHT OUTPUT C2 C3 DIMMER TRAVEL % 19 100% Lite-Puter ISO 9001 CERTIFIED 5-7 Maximum Output Waltage Limit Setting : Maximum waltage limit setting From 50%---FF% (Full lighting) : All channels 1: 1st channel 2: 2th channel 3: 3th channel 4: 4th channel 5: 5th channel 6: 6th channel 7: 7th channel 8: 8th channel 9: 9th channel A : 10th channel B : 11th channel C : 12th channel Indicator key : Press 4: Increase channels. Press 5: Increase percentage of waltage Press 6: Decrease percentage of waltage. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE JBSYSTEMS LIGHT DX-1220

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual JBSYSTEMS LIGHT DX-1220 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag