User manual JBSYSTEMS LIGHT MINI LED MANAGER V 1.1

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual JBSYSTEMS LIGHT MINI LED MANAGER. We hope that this JBSYSTEMS LIGHT MINI LED MANAGER user guide will be useful to you.

Lastmanuals help download the user guide JBSYSTEMS LIGHT MINI LED MANAGER.


Mode d'emploi JBSYSTEMS LIGHT MINI LED MANAGER
Download
Manual abstract: user guide JBSYSTEMS LIGHT MINI LED MANAGERV 1.1

Detailed instructions for use are in the User's Guide.

[. . . ] Enclosure prepared for easy installing against the wall. The lightning flash with arrowhead symbol within the equilateral triangle is intended to alert the use or the presence of un-insulated "dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock. The exclamation point within the equilateral triangle is intended to alert the user to the presence of important operation and maintenance (servicing) instructions in the literature accompanying this appliance. This symbol means: indoor use only This symbol means: Read instructions This symbol means: Lamp Control Gear To prevent fire or shock hazard, do not expose this appliance to rain or moisture. [. . . ] Clean by wiping with a polished cloth slightly dipped with water. Do not use volatile liquids such as benzene or thinner which will damage the unit. Since this unit uses a cooling fan, the interior of the device should be cleaned annually using a vacuum cleaner or air-jet. INTERNAL MICRO: used for sound activated chases. This input receives instructions from a DMX-controller or from another Mini Led Manager when used in master/slave mode. DMX OUTPUT: 3pin female XLR-connector used to connect the Mini Led Manager with the next DMX appliance in the chain or with another Mini Led Manager when used in master/slave mode. The mini LED Manager can also be used as controller for other LED projectors like for example "LED PAR56/64" 4. ON/OFF SWITCH: used to switch the unit on/off. DIP SWITCHES: when used in DMX mode (DIP10 = OFF) you can set the DMX-starting address of the unit. When used in stand-alone mode (master, DIP10 = ON), you can use the DIP-switches to set different pre-programmed options. AUTO DMX ADDRESS BUTTON: see further to learn how to set the DMX address easily. OUTPUT CABLE: used to connect different 24Vdc common anode LED projectors. Load: 100W) The cable uses a special 4pin female connector. You can use the supplied conversion cable to easily connect different projectors. OUTPUT MONITOR: you can check the separate output state of the 3 colors (red, green and blue) 9. ANALOG SWITCH INPUT: used to connect any external analog switch. This external switch can be used to switch the general output of the Mini LED Manager on/off. (external blackout) See further for more information on how to connect the analog switch. MAINS FUSE: Always replace this fuse with a fuse that has the same characteristics!Use the dipswitches 1~9 to set the DMX address from 0 to 511. The first 9 DIP-switches correspond to a certain DMX-value: DIP #1 #2 #3 #4 #5 #6 #7 #8 #9 Value 1 2 4 8 16 32 64 128 256 You can combine the values of these switches to obtain any starting address between 1 and 512: Begin address = 01 switch 1=ON values: 1 Begin address = 05 switch 1+3=ON values: 1+4 = 5 Begin address = 09 switch 1+4=ON values: 1+8 = 9 Begin address = 13 switch 1+3+4=ON values: 1+4+8 = 13 . Begin address = 62 switch 2+3+4+5+6=ON values: 2+4+8+16+32 = 62 DIP10 = ON Master operation (stand-alone) Use the dipswitches 1~9 to set the mode, speed, patterns, fixed color color. [. . . ] Make sure that ALL DIP-switches are set to OFF position!Make sure the DMX cables of all units are connected. Set the DMX-channel, that you want to assign as DMX-start address on your mini LED Manager, to maximum (value 255) Press the "Auto DMX address" button (6) on the first mini LED Manager in the chain for about 5seconds. The first mini LED Manager in the chain will receive the DMX-start address you chose and it will automatically calculate and program the DMX addresses of all the other units in the DMX-chain! [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE JBSYSTEMS LIGHT MINI LED MANAGER

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual JBSYSTEMS LIGHT MINI LED MANAGER will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag