User manual KAZ BP 1500

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual KAZ BP 1500. We hope that this KAZ BP 1500 user guide will be useful to you.

Lastmanuals help download the user guide KAZ BP 1500.


Mode d'emploi KAZ BP 1500
Download
Manual abstract: user guide KAZ BP 1500

Detailed instructions for use are in the User's Guide.

[. . . ] Keep product and batteries away from children. ⷠPeople suffering from cardiac arrhythmia, vascular constriction, arteriosclerosis in extremities, diabetes or users of cardiac pacemakers should consult their doctor before measuring their blood pressure themselves, since deviations in blood pressure values may occur in such cases. ⷠIf you are under medical treatment or taking any medication, please consult your doctor first. ⷠThe use of this blood pressure monitor is not intended as a substitute for consultation with your doctor. [. . . ] Use alkaline batteries, type LR 03 (AAA) as supplied with this product. ⷠRemove the battery compartment cover (F) and insert two batteries with correct polarity (see symbol in the battery compartment (E)). They should not be disposed of in the household waste, but at appropriate collection sites or at your retailer. Key rules for accurate blood pressure measurement ⷠAlways take readings at the same time of day, ideally in the morning, under the same conditions. ⷠDo not measure within 30 minutes after smoking, coffee or tea consumption. ⷠTake off wrist watch and jewelry before fitting the monitor on the measuring arm. ⷠWhile taking a measurement, sit down, relax, keep still, especially the hand of the measuring arm, do not move or speak. Wait approximately 3 minutes before repeating a measurement. Fasten the monitor on the palm side of your wrist, roughly 2 cm below the palm line. While measurement is in progress, do not move or speak. If used according to the use instructions, periodic recalibration is not required. If at any time, you question the measuring accuracy, please contact a Braun Service Centre. ­­­ While measuring (during deflation of the cuff), you can hear a clicking sound with every detected heartbeat. Inflation above 320 mmHg The device works with a special deflation procedure (stepwise deflation). Reason Blood pressure is a fluctuating value. For each measurement, hold the monitor at heart level. While measuring, relax, keep still, do not move or speak. Readings were not consistently taken at heart level. Talking, coughing, laughing, moving etc. Model: Operation principle: Display: Measuring range: Blood pressure measurement: Laboratory accuracy: BP1650 / BP 1500 Oscillometric method Liquid Crystal Display 0­320 mmHg (cuff pressure) 40­199 / min (pulse rate) 20 mmHg (minimum diastolic value) 300 mmHg (maximum systolic value) ± 3 mmHg (cuff pressure) ± 5 % of reading (pulse rate) 21 According to AAMI-SP10 with auscultatory reference: < 5 mmHg systematic offset < 8 mmHg standard deviation Automatic Step valve 2 batteries, type LR 03 (AAA) + 10 °C to + 40 °C ­ 20 °C to + 60 °C Up to 85% RH Suitable for wrist circumference of 13 to 21 cm According to AAMI-SP10 with auscultatory reference. [. . . ] Model: Operation principle: Display: Measuring range: Blood pressure measurement: Laboratory accuracy: BP1650 / BP 1500 Oscillometric method Liquid Crystal Display 0­320 mmHg (cuff pressure) 40­199 / min (pulse rate) 20 mmHg (minimum diastolic value) 300 mmHg (maximum systolic value) ± 3 mmHg (cuff pressure) ± 5 % of reading (pulse rate) 21 According to AAMI-SP10 with auscultatory reference: < 5 mmHg systematic offset < 8 mmHg standard deviation Automatic Step valve 2 batteries, type LR 03 (AAA) + 10 °C to + 40 °C ­ 20 °C to + 60 °C Up to 85% RH Suitable for wrist circumference of 13 to 21 cm According to AAMI-SP10 with auscultatory reference. (Please note that a validation against intra-arterial measurements can lead to different results for devices which are calibrated against auscultatory reference. If device is not used within specified temperature and humidity ranges the technical accuracy can not be ensured. This device conforms to the following standards: DIN EN 60601-1: 3/96 «Medical electrical equipment» ­ Part 1: General requirements for safety DIN EN 1060-1: 12/95, AMD 1 09/02 «Non-invasive sphygmomanometers» ­ Part 1: General requirements DIN EN 1060-3: 9/97 «Non-invasive sphygmomanometers» ­ Part 3: Supplementary requirements for electro-mechanical blood pressure measuring systems This product conforms to the provisions of the EC directive 93 /42 / EEC (Medical Device Directive). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE KAZ BP 1500

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual KAZ BP 1500 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag