User manual KB ELECTRONICS KBMG

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual KB ELECTRONICS KBMG. We hope that this KB ELECTRONICS KBMG user guide will be useful to you.

Lastmanuals help download the user guide KB ELECTRONICS KBMG.


Mode d'emploi KB ELECTRONICS KBMG
Download
Manual abstract: user guide KB ELECTRONICS KBMG

Detailed instructions for use are in the User's Guide.

[. . . ] "The Right Control for Your Application. " KB Electronics, Inc. 12095 NW 39 Street, Coral Springs, FL 33065-2516 Telephone: 954-346-4900; Fax: 954-346-3377 6LJQDO , VRODWRU 6, 0* 3DUW 1R , QVWDOODWLRQ DQG :LULQJ , QVWUXFWLRQV IRU 0RGHO . %0* ZLWK 3LHFH )LQJHU6DIH &RYHU This document is supplied with Model KBMG only. Warning!Before installing the SIMG onto the KBMG, the AC power must be disconnected. The following Installation and Wiring instructions are to be used as a supplement to the KBMG Installation and Operating Instructions Manual (Part No. Refer to the SIMG Installation and Operating Instructions Manual (Part No. A40269) for specific and external signal following connections. [. . . ] If no load is applied to the motor, the motor will rotate at a speed proportional to the torque setting as set by the main potentiometer (see fig. By using the ACCEL and DECEL trimpots, the application of torque can be made more gradual or less gradual as required by the application. A maximum torque can be established using the current selector jumper, J2, which can be further modified by using the FWD and REV CL trimpots. 5 ­ JUMPER J6 SETTING Regenerate to Stop (RTS) ­ Coast to Stop Regenerate to Stop This function operates in conjunction with the Enable circuit, which is used to start and stop the control electronically. If the circuit connecting terminals "EN" and "COM" on terminal block TB1 are opened, the control will cause the motor to stop. When jumper J6 is in the factory position (RTS), the motor will regenerate to a stop. If J6 is changed to the coast to stop (CTS) position, the motor will coast to a stop when the "EN" - "COM" circuit is opened. Note: Control will not run unless a jumper or closed contact is connected between the "EN" and "COM" terminals. 12 FIG. 6 ­ SPEED CONTROL MODE 13 FIG. 7 ­ TORQUE CONTROL MODE (Linear) 14 IV. Mount the KBMG-212D on a flat surface in an atmosphere free of moisture, metal chips, and corrosion. A 5K ohm remote speed potentiometer is provided with each control. Install potentiometer using hardware provided. Be sure to install insulating disk between potentiometer and inside of front panel. Enclosure ­ When mounting the KBMG-212D in an enclosure, it must be large enough to allow the proper heat dissipation. A 12"12"12" enclosure is suitable when the control is not mounted on an auxiliary heatsink. A 12"12"24" enclosure is appropriate at full rating (11. 0 amps) when the control is mounted on an auxiliary heatsink KB P/N 9861. Read Safety Warning before attempting to use this Warning!To avoid erratic operation do not bundle AC line and motor wires with potentiometer, voltage following, enable, inhibit or other signal wiring. Use shielded cables on all signal wiring over 12" (30 cm) ­ Do not ground shield. TABLE 6 ­ TERMINAL BLOCK WIRING INFORMATION Terminal Block Designation TB1 Connection Designation Logic Conections Supply Wire Gauge Minimum 22 Maximum 14 Maximum Tightening Torque (in-lbs) 3. 5 15 Wire control in accordance with National Electrical FIG. 8 ­ AC LINE CONNECTION Code requirements and other local codes that apply. [. . . ] Run motor at approximately 30 ­ 50% of rated speed under no load and measure actual speed. Rotate IR Comp trimpot so that loaded speed is the same as the unloaded speed measured in the previous step. Control is now compensated so that minimal speed change will occur over a wide range of motor load. Note: Excessive IR Comp will cause unstable (oscillatory) operation. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE KB ELECTRONICS KBMG

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual KB ELECTRONICS KBMG will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag