If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual KENMORE STANDARD-FLOW-VALVE-SOFTENER-INSTALLATION. We hope that this KENMORE STANDARD-FLOW-VALVE-SOFTENER-INSTALLATION user guide will be useful to you.

Lastmanuals help download the user guide KENMORE STANDARD-FLOW-VALVE-SOFTENER-INSTALLATION.


Mode d'emploi KENMORE STANDARD-FLOW-VALVE-SOFTENER-INSTALLATION
Download
Manual abstract: user guide KENMORE STANDARD-FLOW-VALVE-SOFTENER-INSTALLATION

Detailed instructions for use are in the User's Guide.

[. . . ] INSTALLATION MANUAL for softeners with standard flow valve Caution: Read All Safety Guides Before You Start To Install Your Softener. Water Softeners u Safety Guides u Unpacking u Where To Install If you have questions when installing, operating or maintaining your softener, and when setting the timer, call this toll--free number. . . u How To Install u Pressure Testing 1-800-426-9345 SAVE THIS MANUAL Use plastic bag and tie provided, to hang manuals nearby the softener for future reference. Sears, Roebuck and Co. , Hoffman Estates, IL 60179 USA PRINTED IN U. S. A. INTRODUCTION This manual gives you the steps needed to install your new Sears Water Softener. To better understand how the water softener is installed, and to know what you will need, please read this entire manual before beginning. After you have installed the water softener, the included Owners Manual tells you how to start, program, operate and maintain it. The owners manual also has the product warranty, and a listing of repair parts available from Sears. Your Sears Water Softener will remove hardness minerals (measured in grains per gallon¼ gpg) and some clear water iron (measured in parts per million¼ ppm) from water. See the specifications, in your owners manual, for the maximum limits of hardness and iron removal. [. . . ] Do not use the installation kit, Sears Stock No. 42---3441, or the flexible connectors, Sears Stock No. CAUTION: DO ALL SOLDERING BEFORE CONNECTING SWEAT ADAPTOR TO INLET ---OUTLET ADAPTORS OR BYPASS VALVE. SEARS KITS AND VALVES TO MAKE INSTALLING YOUR SOFTENER EASIER 1 BYPASS VALVE (Plastic) Sears Stock No. Snap the 2 large holding clips into place, from the top down as shown. CAUTION¼ Be sure the clips snap firmly into place so the adaptors will not pull out. INSTALL THE INLET AND OUTLET ADAPTORS OR SEARS BYPASS VALVE. 4, 5 AND 6). -- If not already done, put a light coating of silicone grease or Vaseline on the bypass valve o-rings. Push the bypass valve into the softener valve as far as it will go. Snap the 2 large holding clips into place, from the top down as shown. NOTE: If you will install the bypass valve (use following steps a and c), the adaptors are not used. If you do not install the bypass valve, you must use the adaptors (use following steps a and b). a. Visually check and remove any foreign materials from the valve inlet and outlet ports (FIG. 4). CAUTION¼ Be sure the clips snap firmly into place so the bypass valve will not pull out. GO TO PAGE 15. 12 SECTION 3 3A. STEP BY STEP GUIDES TO INSTALL ASSEMBLE INLET--- OUTLET ADAPTORS, OR PLASTIC BYPASS VALVE ADAPTORS OR BYPASS VALVE FIG. 6 BYPASS VALVE TURNED DOWNWARD NOTE: The softener includes either the adaptors, or the bypass valve, depending on the model. ELECTRONIC DEMAND MODELS ONLY Be sure the turbine and support are firmly in place in the valve outlet. 13 SECTION 3 3B. STEP BY STEP GUIDES TO INSTALL INSTALL 3--- VALVE BYPASS, OR SINGLE BRASS BYPASS VALVE 1. INSTALLING 3 VALVE BYPASS, OR SEARS BYPASS VALVE, STOCK NO. Loosely put together pipe, fittings, and the 3 valves or Sears special bypass valve. Place valve(s) within easy reach. FIG. Cut the house main water pipe where you IMPORTANT: When looking at the front of the softener, the inlet is on the right side. If water in your house main water pipe runs from left to right, be sure to use a "cross-over" as shown on page 9. b. When all pipe, fittings and valves make a good fit together, tighten all threaded joints (use pipe dope on outside threads), or solder. 14 SECTION 3 3C. STEP BY STEP GUIDES TO INSTALL LOCATE SOFTENER AND CONNECT PIPES 1. MOVE THE SOFTENER INTO PLACE Move the softener into place, onto a level and smooth surface. If needed, put a piece of 3/4² plywood, at least 17² x 20², under the tank. Then put spacers under the plywood to level the softener. [. . . ] Outlets are grounded to protect you from shock when you touch any electric appliance plugged into the outlet. If you didn' install a 3-valve bypass, or a brass t single bypass valve (FIG. 12), the cold water pipe ground is broken. FIG. 13 COLD WATER PIPE GROUND IMPORTANT: Be sure the cold water pipe has direct metal to metal contact all the way to the ground. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE KENMORE STANDARD-FLOW-VALVE-SOFTENER-INSTALLATION

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual KENMORE STANDARD-FLOW-VALVE-SOFTENER-INSTALLATION will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag