User manual KONICA MINOLTA DIMAGE VIEWER V2.2

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual KONICA MINOLTA DIMAGE VIEWER V2.2. We hope that this KONICA MINOLTA DIMAGE VIEWER V2.2 user guide will be useful to you.

Lastmanuals help download the user guide KONICA MINOLTA DIMAGE VIEWER V2.2.


Mode d'emploi KONICA MINOLTA DIMAGE VIEWER V2.2
Download
Manual abstract: user guide KONICA MINOLTA DIMAGE VIEWER V2.2

Detailed instructions for use are in the User's Guide.

[. . . ] E INSTRUCTION MANUAL 9222-7300-11 SY-A306/ME-0306 2 BEFORE YOU BEGIN Before installing the DiMAGE Viewer software, read the data-transfer section in the camera manual. This section details how to connect the camera to a computer using the supplied USB cable. The s in this manual assume the camera is connected to the computer with a USB cable as described in the camera manual. This instruction manual does not provide instruction in the basic operation of the personal computers, or the basic operation of Windows or Macintosh operating systems; refer to the manuals supplied with the computer. [. . . ] The values of the image will be adjusted based on the selected point. The default level for the white point is 255 for each RGB channel. Click the black-point button. With the dropper tool, click on the darkest neutral area of the image to define it as the black point. The values of the image will be adjusted based on the selected point. The default level for the black point is 0 for each RGB channel. 52 ADVANCED IMAGE PROCESSING Click the gray-point button. The grey point controls the color of the image. With the dropper tool, click a neutral area of the image to be defined as the gray point. The area used to calibrate the gray point must be neutral. The brightness level of the area is not important, but if the area has a definite color, the image will not be color balanced correctly. Click and hold the apply button to show the change on the histogram. Click the reset button to cancel all corrections. 53 SETTING THE WHITE AND BLACK-POINT VALUES The white and black-point values are set to 255 and 0 for each RGB level. Changing these values allow the calibration of an image with no true white or black. This is an advanced image-processing tool. Double-click on either the white-point or black-point button to activate the point-value-setting dialog box. Input the new white-point or black-point values. With the point-value-setting dialog box open, the mouse pointer can be used to measure the color of any point on the displayed image. Press the shift key (Windows) or command key (Macintosh) to display the CMY levels in the RGB display. The RGB display shows the original values for the image on the left and the current values for the image on the right. Calibrate the image following the steps in white, black, and gray point corrections section. 54 ADVANCED IMAGE PROCESSING TONE-CURVE / HISTOGRAM AUTO SETTING Click the auto-setting button. The change is immediately reflected in the displayed image. The auto-setting function automatically adjusts the tone curve and histogram to maximize image data. The darkest pixels in the image are set to a black level for 0, the brightest pixels are set to a white level of 255, and the rest of the pixels are distributed between them equally. To view the change in the histogram, press the apply button. Click the reset button to cancel the auto setting. DISPLAYING THE COLOR HISTOGRAMS Click the color-histogram button to view the red, green, and blue histograms. Click the histogram RGB display button again to close the color histogram display. 55 HISTOGRAM CORRECTIONS The histogram indicates the distribution of pixels with specific brightness and color values of the displayed image. Using the histogram can maximize the output of the image data. Changes made with the histogram are also displayed on the tone curve. [. . . ] Windows 98/98SE/Me: C:\ Windows \ ApplicationData \ DiMAGE \ 7300 \ Prefs. Open the DiMAGE Viewer to confirm the Jobs can be loaded. 88 VIEWER NOTES Macintosh OS X 1. Log on to your computer an administrator. Open the 7300 folder: /Library/Preferences/7300. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE KONICA MINOLTA DIMAGE VIEWER V2.2

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual KONICA MINOLTA DIMAGE VIEWER V2.2 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag