User manual KONICA BC-10

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual KONICA BC-10. We hope that this KONICA BC-10 user guide will be useful to you.

Lastmanuals help download the user guide KONICA BC-10.


Mode d'emploi KONICA BC-10
Download
Manual abstract: user guide KONICA BC-10

Detailed instructions for use are in the User's Guide.

[. . . ] The operation must never been performed. The instruction must be strictly adhered to. Disconnect the AC power cord from the AC outlet. Connect the grounding terminal as instructed. [. . . ] · DISABLED: Select this option if the terminator is not to be used. 19 Connecting the VIVID 9i to a Computer 7 Press . Setting is now complete. Note To cancel the setting and return the SCSI SETTINGS screen to its original state, press CANCEL . 20 Starting and Quitting Starting the VIVID 9i [Operating Procedure] 1 Set the power switch to ON (" "). Power will be supplied to the VIVID 9i and initial setup is performed. After several dozen seconds, "PLEASE OPEN LASER BARRIER AND PRESS ANY KEY" will be displayed on the viewfinder. POWER AC IN SCSI Note When turning power ON again after it has been turned OFF, wait at least 5 seconds before doing so. Failure to observe this may result in malfunction or breakdown of the VIVID 9i. Memo To ensure precise measurement, allow the unit to warm up for at least 10 minutes. 2 Remove the lens cap from the receiving lens. 3 Remove the laser barrier. 21 Starting and Quitting 4 Press any key. The MONITOR view will appear, indicating that the VIVID 9i is now ready for operation. EXTEND 720MM 22 Starting and Quitting Quitting the VIVID 9i [Operating Procedure] 1 Set the power switch to OFF (" Power will be turned OFF. "). POWER AC IN SCSI 2 Attach the lens barrier. WARNING To ensure safety, please keep the lens barrier in place at all times when the unit is not in use. 3 Fit the lens cap onto the receiving lens. Note Please keep the receiving lens cap and the laser barrier place in place when you are not carrying out scanning. Dust and scratches on the laser and lens can adversely affect scanning precision. 23 Mounting to the Tripod When using the instrument with the tripod, first attach the tripod attachment to the instrument, and then attach the instrument to the panhead/tripod. CAUTION · Make sure that the tripod attachment, panhead and tripod are secured to the instrument and each fastener on the tripod is firmly tightened. Failure to observe this point may result in the tripod overturning or the instrument dropping. · When placing the tripod on a floor, examine the floor conditions and flatness to make sure that the tripod is stably placed. · After measurement is completed, the instrument must be removed from the tripod before storing them. If the instrument is stored with the tripod attached, the tripod may overturn or the instrument may drop, resulting in accidents. 1. · Dust and dirt collected on the lens mount surface on the body side must also be removed with a camera air blower etc. · SCSI communication is not available while the lens is being replaced. Please close the Polygon Editing Tool software's control dialog before starting replacement. [Operating Procedure] 1 Remove the lens hood. Turn counterclockwise to align with the cutouts. Memo The lens hood can be fixed with its bayonet mount. 2 Turn the lens fixing ring counter-clockwise to loose it completely. Memo The lens fixing ring can be fixed with its screw mount. 29 Replacing the Lens and Field Calibration 3 Hold the external edge of the fixing ring and pull it out. Memo Hold the ring with your finger located near the red mark on the lens. This will facilitate pulling the lens. Note Attach the lens cap to the removed lens, place it in the lens case and keep it in a safe place. The following information will appear in the viewfinder as shown on the right. CHANGE LENS S/N 2001005 PRESS ANY KEY AND SCAN FIELD CALIBRATION SYSTEM 4 Attach the desired lens. · Align the red mark on the lens with the one on the lens mount socket, and insert the lens until a click is heard. Red mark Memo Hold the ring with your finger located near the red mark on the lens. This will facilitate inserting the lens. 5 Turn the lens fixing ring clockwise to secure the lens. Note After tightening the lens, make sure that the red mark on the ring is aligned with the red mark on the body. Tightening ring Red mark 30 Replacing the Lens and Field Calibration 6 Attach the lens hood. Align the cutouts, and then turn clockwise. Memo The hood must be turned until it contacts the bayonet mount socket. 7 8 Press any key. After several dozen seconds, "PLEASE OPEN LASER BARRIER AND PRESS ANY KEY" will be displayed on the viewfinder. The viewfinder displays the monitor screen, and the digitizer is ready for use. Note Place a lens cap on the lens you removed, put it in its case, and store in a safe place. 9 Use the field calibration system and the Polygon Editing Tool software to calibrate the system. Ref. For the field calibration procedure, refer to "Field Calibration" on the next page. 31 Field Calibration The field calibration on this unit is done using the Field Calibration System. [. . . ] Field calibration values have been reinitialized. Please try field calibration again. The lens is now being replaced. Press any key and scan field calibration system. Highly dangerous!Turn off the power immediately and contact a KONICA MINOLTA SENSING authorized service facility. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE KONICA BC-10

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual KONICA BC-10 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag